Bluefin BFMS0926PR-01 Remote Controller Owner’s Manual
- June 20, 2024
- BLUEFIN
Table of Contents
Bluefin BFMS0926PR-01 Remote Controller Owner’s Manual
IMPORTANT NOTE:
Thank you for purchasing our air conditioner. Please read this manual
carefully before operating your new air conditioning unit and make sure to
save this manual for future reference.
Remote Controller Specifications
NOTE : For units labeled RG10Y1 (D2)/BGEF,RG10Y2(D2S)/BGEF: If the unit is turned off while set to COOL, AUTO or DRY mode with the set temperature less than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again. If the unit is turned off under HEAT mode with the set temperature more than 24°C, the set temperature will be automatically set to 24°C when you turn on the unit again.
Quick Start Guide
NOT SURE WHAT A FUNCTION DOES?
Refer to the How to Use Basic Functions and How to Use Advanced Functions
sections of this manual for a detailed description of how to use your air
conditioner.
SPECIAL NOTE
- Button designs on your unit may differ slightly from the examples shown.
- If the indoor unit does not have a particular function, pressing that function’s button on the remote control will have no effect.
- When there are discrepancies between “Remote controller Manual” and “USER’S MANUAL” on function description, follow the instructions outlined in the “USER’S MANUAL”
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries. Put the batteries in the remote control before use.
- Slide the back cover from the remote control downward, exposing the battery compartment.
- Insert the batteries, paying attention to match up the (+) and (-) ends of the batteries with the symbols inside the battery compartment.
- Slide the battery cover back into place.
BATTERY NOTES
For optimum product performance:
- Do not mix old and new batteries, or batteries of different types.
- Do not leave batteries in the remote control if you don’t plan on using the device for more than 2 months.
BATTERY DISPOSAL
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal of batteries.
TIPS FOR USING REMOTE CONTROL
- The remote control must be used within 8 meters of the unit.
- The unit will beep when remote signal is received.
- Direct sunlight, curtains, and other obstructions can interfere with the infrared signal receiver.
- If the remote isn’t going to be used for a period of over 2 months, remove the batteries to prevent leakage.
NOTES FOR USING REMOTE CONTROL
This device complies with the local national regulations.
- In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
- In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment.
Buttons and Functions
Before you begin using your new air conditioner, make sure to familiarize yourself with its remote control. The following is a brief introduction to the remote control itself. For instructions on how to operate your air conditioner, refer to the How to Use Basic Functions section of this manual.
Model:
RG10A2(D2S)/BGEFU1,RG10Y2(D2S)/BGEF
RG10A10(D2S)/BGEF(20-28 C/68-82 F)
RG10A(D2S)/BGEF & RG10A(D2S)/BGEFU1(Fresh feature is not available)
RG10A2(D2S)/BGCEFU1 & RG10A2(D2S)/BGCEF (Cooling only models, AUTO mode and
HEAT mode are not available)
Model : RG10A1(D2S)/BGEF
Model:
RG10B(D2)/BGEF(Fresh feature is not available)
RG10B10(D2)/BGEF & RG10B10(D2)/BGCEF(20-28 C/68-82 F)
RG10B2(D2)/BGCEF & RG10B10(D2)/BGCEF (Cooling only model, AUTO mode and HEAT
mode are not available )
RG10Y1(D2)/BGEF
Model : RG10B1(D2)/BGEF
Remote Screen Indicators
Information are displayed when the remote controller is power up.
Note :
The indicators displayed in the above figure are for illustrative purposes
only. During normal operation, only active functions and relevant information
will be displayed.
How to Use Basic Functions
ATTENTION
Before operation, please ensure the unit is plugged in and power is available.
AUTO Mode
NOTE :
- In AUTO mode, the unit will automatically select the COOL, FAN, or HEAT function based on the set temperature.
- In AUTO mode, fan speed cannot be set.
COOL or HEAT Mode
DRY Mode
NOTE : In DRY mode, fan speed is automatically controlled and cannot be
manually set.
FAN Mode
NOTE : In FAN mode, you can’t set the temperature. As a result the
temperature won’t be displayed on the remote’s screen.
Setting the TIMER
TIMER ON/OFF – Set the amount of time after which the unit will automatically turn on/off.
TIMER ON setting
TIMER OFF setting
NOTE:
- When setting the TIMER ON or TIMER OFF, the time will increase in 30 minute increments up to 10 hours. After 10 hours and up to 24, it will increase in 1 hour increments. (For example, press 5 times to get 2.5h, and press 10 times to get 5h,) The timer will revert to 0.0 after 24.
- Cancel either function by setting its timer to 0.0h.
TIMER ON & OFF setting(example)
Keep in mind that the time periods you set for both functions refer to hours after the current time.
Example: If current timer is 1:00PM, to set the timer as above steps, the unit will turn on 2.5h later (3:30PM) and turn off at 6:00PM.
How to Use Advanced Functions
Swing function
Press Swing button
The horizontal louver will swing up and down automatically when pressing Swing button. Press the swing button again to make it stop.
Hold the swing button for more than 2 seconds to activate the vertical louver swing function. (Model dependent)
Airflow direction
You can set five different airflow directions by continuing to press the swing button. The louver can be move at a certain range each time you press the button. Press the button until the direction you prefer is eached.
NOTE : When the unit is off, press and hold MODE and SWING buttons together for one second. the louver will open to an angle convenient for cleaning. Press and hold MODE and SWING buttons together for one second to reset the louver (Model dependent).
LED DISPLAY
Press this button to turn the display on the indoor unit on and off.
Hold the button for 5 seconds to display the actual room temperature. Hold the button for 5 seconds again to revert to displaying the set temperature.
ECO/GEAR function
ECO operation:
While in cooling mode, press this button to automatically set the temperature to 24°C / 75°F, and the fan speed to Auto to save energy (only when the set temperature is less than 24°C / 75°F). If the set temperature is above 24°C / 75°F, press the ECO button to change the fan speed to Auto. The set temperature will remain the same.
NOTE :
Pressing the ECO/GEAR button, modifying the mode or adjusting the set
temperature to less than 24°C / 75°F will stop ECO operation. While in ECO
mode, the set temperature should be 24°C / 75°F or higher. If your desired
temperature is below 24°C / 75°F, you may need to turn off ECO mode by
pressing the button again.
GEAR operation:
Press the ECO/GEAR button to enter the GEAR operation as following:
75%(up to 75% electrial energy consumption)
⬇️
50%(up to 50% electrial energy consumption)
⬇️
Previous setting mode.
In GEAR mode, the display on the remote controller will alternate between electical energy consumption and set temperature.
SHORTCUT function
Press SHORTCUT button(some units)
Silence function
Hold Fan button for more than 2 seconds to activate/disable Silence function (some units).
Because the compressor operates at a lower frequency while in silent mode, you may notice reduced heating or cooling capacity. Press ON/OFF, Mode, Sleep, Turbo or Clean button while operating will cancel silence function.
FP function
Note : This function is for heat pump air conditioner only.
Press this button 2 times during one second under HEAT Mode and setting
temperature of 16 ° C / 60°F or 20°C / 6°F(for models of RG10A10(D2S)/BGEF,
RG10B10(D2)/BGEF and RG10B10(D2)/BGCEF) to activate FP function.
Press On/Off, Sleep, Mode, Fan and Temp. button while operating will cancel
this function.
LOCK function
SET function
- Press the SET button to enter the function setting, then press SET button or TEMP ∨ or TEMP ∧ button to select the desired function. The selected symbol will flash on the display area. Press the OK button to confirm.
- To cancel the selected function, just perform the same procedures as above.
- Press the SET button to scroll through operation functions as follows:
Breeze Away ( ) Fresh ( ) Sleep( ) Follow Me( ) AP mode( **)
[ ⁕** ]: If your remote controller has Breeze Away button, Fresh button or Sleep button, you cannot use the SET button to select the Breeze Away, Fresh or Sleep feature.
Breeze Away function ( ) (some units) :
This feature activates indirect airflow to create a more natural, breeze-like
effect.
NOTE: This feature is available under cool, Fan and Dry mode only.
FRESH function ( ) (some units) :
When the FRESH function is initiated, the ion generator is energized and will
help to purify the air in the room.
Sleep function ( ) :
The SLEEP function is used to decrease energy use while you sleep (and don t
need the same temperature settings to stay comfortable). This function can
only be activated via remote control.
For the detail, see “sleep operation” in “USER’S MANUAL”.
Note : The SLEEP function is not available in FAN or DRY mode.
Follow me function ( ):
The FOLLOW ME function enables the remote control to measure the temperature
at its current location and send this information to the air conditioner in 3
minute intervals. When using AUTO, COOL or HEAT modes, measuring ambient
temperature from the remote control(instead of from the indoor unit itself)
will enable the air conditioner to optimize the temperature around you and
ensure maximum comfort.
NOTE : Press and hold Turbo button for seven seconds to start/stop memory feature of Follow Me function.
- If the memory feature is activated, “ON” displays for 3 seconds on the screen.
- If the memory feature is stopped, “OFF” displays for 3 seconds on the screen.
- While the memory feature is activated, press the ON/OFF button. Switching modes or power failure will not cancel the Follow me function.
AP function ( )(some units) :
Choose AP mode for wireless network configuration. For some units you may need
to press the LED button seven times in 10 seconds to enter AP mode.
The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
CR2756-RG10(D2S)
16117000A37345