GE current LED8DRS4-9SC LED Recessed Downlight Installation Guide
- June 9, 2024
- GE current
Table of Contents
LED
Recessed Downlight
LED8DRS4/9SC
Installation Guide
LEDL157
DOC-2003347
LED8DRS4-9SC LED Recessed Downlight
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
RISK OF FIRE OR ELECTRIC SHOCK
LED Retrofit Kit installation requires knowledge of luminaire electrical
systems. If not qualified, do not attempt installation. Contact a qualified
electrician. Install this kit only in luminaries that have the construction
features and dimensions shown in the drawings and where the input rating of
the retrofit kit does not exceed the input rating of the luminaire. Do not
make or alter any open holes in an enclosure of wiring or electrical
components during kit installation. To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other sharp objects. THE RETROFIT
KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE
COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT
MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE
AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE
LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS. Installers should
examine all parts that are not intended to be replaced by the retrofit kit for
damage and replace any damaged parts prior to installation of the retrofit
kit. Min. Lamp Compartment Dimensions: 101.6mm (dia) x 135 mm (h).
The units covered in this report are intended to retrofit Type IC or non-IC
recessed mount Listed luminaires with instructions to remove the existing
trim. The minimum dimensions of luminaries are tabulated above. These products
are intended to be used in dry or damp locations. These products are
classified as to FIRE and SHOCK hazards only.
This device complies with CAN ICES-005B.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifications not expressly approved by the manufacturer could void the user’s
authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: reorient or relocate
the receiving antenna, increase the separation between the equipment and
receiver, connect the equipment into an outlet on a circuit different from
that to which the receiver is connected, or consult the dealer or an
experienced radio/TV technician for help.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Components Supplied
- One LED retrofit
- One installation instructions sheet
Prepare Electrical Wiring
Electrical Requirements
The LED driver must be supplied with 120 VAC 60 Hz.
Grounding Instructions
The grounding and bonding of the overall system shall be done in accordance
with National Electric Code (NEC) Article 600 and local codes.
Model No. | Input Voltage | Input Frequency | Input Wattage | Input Current |
---|---|---|---|---|
LED8DRS4/9SC | 120 V | 60 Hz | 8 W | 0.085 A |
SC denotes Selectable Color Temperature
Installation
-
Remove lamp from the packaging and check that the “Flip Clips” are firmly attached. Adjust color temperature to desired setting.
-
TURN OFF POWER at the source to the recessed housing(s) that you are installing the fixture(s) in.
-
Remove existing trim and bulb, revealing the existing socket.
-
Screw medium base socket adapter into existing socket inside the housing.
-
Link the socket adapter to the matching connector clip attached to the fixture.
-
Guide fixture into the housing and gently push up until flush with the ceiling.
-
Restore power to the lighting system.
www.gecurrent.com
© 2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE
monogram are trademarks of the
General Electric Company and are used under license. Information provided is
subject to change without
notice. All values are design or typical values when measured under laboratory
conditions.
LEDL157 (Rev 08/12/22)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>