Please read the manual carefully before use
CAUTION DO NOT OPEN THE HOUSING SHOCK HAZARD
Installation and operating instructions:
-
Plugged into a grounded power outlet .
-
Install the equipment in a well-ventilated place at least 50cm from any surface, and ensure that the ventilation slots are not
-
Disconnect the equipment from the power supply before any operation.
-
The ambient temperature should not exceed 40°C, and the maximum ambient temperature is 45°C. Don’t operate the device at higher
-
The equipment should be stopped immediately, if a fault occurs, and do not repair the equipment by Improper maintenance can result in damage and malfunction. Contact technical support for repair approval. Only the same accessories can be used with the original parts, and make sure the power cord is not blocked or damaged.
-
Do not expose your eyes to light sources, which can be a sign of a seizure in sensitive people.
-
The lamps are only used for decoration and not suitable for ordinary household
-
Replacing the fuse: Unplug the device from the power supply, remove the fuse holder from its original position with a screwdriver, take out the burnt fuse, replace the fuse with the same characteristics, then re-rotate the screw, and connect the device to the power supply
-
WARNING: Stop using it if the fuse is still blowing after being replaced. Please contact customer support for further instructions, continued use may cause serious
-
Fix the equipment with the screw holes on the bracket to ensure that the equipment is firmly fixed to prevent vibration and movement during operation, and always check whether the structure of the equipment is strong enough to withstand equipment that is at least ten
-
The equipment must be fixed by professionals in places that elders and children cannot reach, and no one can pass under or over the pedestrian crossing.
-
End-of-life of the product: This sign indicates that this product should not be thrown into household waste in European Community countries and that waste should be recycled to support the sustainable recycling of resources in order to protect the environment and human health If you need to recycle used electrical appliances, please go to an electrical appliance collection center or contact the dealer where you purchased the product to ensure the ecological recycling of the product.
-
Before cleaning the device, disconnect it from the power source if connected. Do not use harsh cleaners.
Wipe off dust or dirt from the product with a clean cloth.
We are not responsible for damage caused by incorrect handling, improper use or wear and tear. -
We reserve the right to make technical modifications.
Connection of DMX512 signal
This lamp uses the DMX512 signal control mode. The control signals of each lamp are connected in parallel. When connecting multiple lamp signals, it is best to use a double-core shielded cable. When connecting, each lamp passes through the DMX signal jack on the lamp (XLR socket) INPUT (input) and OUTPUT (output) are connected, and the 3-core XLR plug terminals of the signal line connected to the lamp must correspond to each other. When connecting the signal of the lamp, it is recommended to use a DMX signal terminator. It can be avoided. If the sound causes damage to the control signal, the DMX signal terminator is to connect a 120 ohm 1W resistor between pin 2 and pin 3 of an XLR plug, and connect it to the OUTPUT (output) jack of the last lamp.
Calculation method of starting address code of lamps:
The starting address code of the current lamp is equal to (the starting
address code of the previous lamp) + (the number of channels of the lamp)
Explanation:
- The initial address code value of the first lamp is A001.
- The number of basic channels of the controller should be greater than or equal to the total number of channels used by the lamps.
- Note: When using any controller, each lamp must have its own initial address code, if the initial address code of the first lamp is set to A001, and the channel number of lamps is 16CH; then The start address code of the second lamp is set to A017; the start address code of the third lamp is set to A033; and so on, (this setting method also needs to be determined according to different consoles).
Technical parameters:
Input power: AC90V-240V 50/60Hz
Heat dissipation method: Metal heat conduction
Number of lamp beads: 5 PCS high-brightness lamp beads + 60 PCS three-in-
one lamp beads
Lamp bead type: RGB three-in-one lamp bead + integrated lamp bead
Strobe: 1-25 times/second
Number of DMX control channels: 12/42CH
DMX connector: 3Pin XLR
Control mode: DMX512,Sound Activated, Master-slave, Auto. Display mode:
LED digital tube
-
Key button description
MENU: Function key UP: Plus key DOWN:Minus key ENTER: Confirm key
(Operation instructions: after selecting a function in “MENU”, press “ENTER” key to enter, Then press “UP” and “DOWN” to adjust the value, select the value and press “ENTER” to confirm) -
Digital tube display menu description
No.| content| Function and description
---|---|---
1| A001| Address code (001- -512), B, C key plus or subtract address code value
2| CH12/CH42| Channel mode switching
3| -512/Auto/Soon| DMX-512 mode / self-walk mode / voice-control mode
4| S-(0-99)| Voice control sensitivity, adjusted values of 0-99 -
Channel description
CH12| CH42| function| range| explain
---|---|---|---|---
1| 1| Total dimming| 0-255| from dark to light
2| 2| Total frequency flash| 0-255| from slow to fast
3| 3| Main light 1| 0-255| 0-100% linear dimming
4| 4| Main light 2| 0-255| 0-100% linear dimming
5| 5| Main light 3| 0-255| 0-100% linear dimming
6| 6| Main light 4| 0-255| 0-100% linear dimming
7| 7| Main light 5| 0-255| 0-100% linear dimming
8| 8| Supplemental light all red| 0-255| 0-100% fill light full red
9| 9| Auxiliary light all green| 0-255| 0-100% fill light full green
10| 10| Supplemental light all blue| 0-255| 0-100% fill light full blue
11| 11| Main light + auxiliary light effect| 0-3| dimming mode
4-7| Effect 1
8-11| Effect 2
12-15| Effect 3
16-19| Effect 4
20-23| Effect 5
24-27| Effect 6
28-31| Effect 7
32-35| Effect 8
36-39| Effect 9
40-43| Effect 10
44-47| Effect 11
48-51| Effect 12
52-55| Effect 13
56-59| Effect 14
60-63| Effect 15
64-67| Effect 16
68-71| Effect 17
72-75| Effect 18
76-79| Effect 19
80-83| Effect 20
84-87| Effect 21
88-91| Effect 22
92-95| Effect 23
96-99| Effect 24
100-103| Effect 25
104-107| Effect 26
108-111| Effect 27
112-115| Effect 28
116-119| Effect 29
120-123| Effect 30
124-127| Effect 31
128-131| Effect 32
132-135| Effect 33
136-139| Effect 34
140-143| Effect 35
144-147| Effect 36
148-151| Effect 37
152-155| Effect 38
156-159| Effect 39
160-163| Effect 40
164-167| Effect 41
168-191| Effect 42
192-195| Effect 43
196-199| Effect 44
200-203| Effect 45
| | | 204-207| Effect 46
---|---|---|---|---
208-211| Effect 47
202-205| Effect 48
206-209| Effect 49
210-213| Effect 50
214-217| Effect 51
218-221| Effect 52
222-225| Effect 53
226-229| Effect 54
230-233| Effect 55
234-237| Effect 56
238-241| Effect 57
242-247| Effect 58
248-251| Effect 59
252-255| Effect 60
12| 12| Effect speed| Effect 1-11| 0-63 effect freeze frame
64-159 effect speed changed from fast to slow
160-255 effect speed from slow to fast
Of the effectof 12-60| 0-255, the effect is getting faster and faster
/
| 13| Auxiliary light red 1| 0-255| 0-100% Filler Red 1
14| Light green 1| 0-255| 0-100% auxiliary light green 1
15| Light blue 1| 0-255| 0-100% auxiliary light blue 1
16| Auxiliary light red 2| 0-255| 0-100% Filler Red 2
17| Light green 2| 0-255| 0-100% auxiliary light green 2
18| Light blue 2| 0-255| 0-100% auxiliary light blue 2
19| Auxiliary light red 3| 0-255| 0-100% Filler Red 3
20| Light green 3| 0-255| 0-100% auxiliary light green 3
21| Auxiliary light blue 3| 0-255| 0-100% auxiliary light blue 3
22| Auxiliary light red 4| 0-255| 0-100% Auxiliary Red 4
23| Light green 4| 0-255| 0-100% Backlight Green 4
24| Light blue 4| 0-255| 0-100% Auxiliary Blue 4
25| Auxiliary light red 5| 0-255| 0-100% Auxiliary Red 5
Read User Manual Online (PDF format)