dormakaba XL150-80 Ceiling Mount Instruction Manual

June 19, 2024
dormakaba

XL150-80 Ceiling Mount

“`html

Specifications

Technical Specifications

Ceiling Mount

Single Door

  • XL150: Door leaf weight 330lbs [150kg] (Including weight of
    auxiliary hardware)

  • XL80: Door leaf weight 176lbs [80kg]

Double Door

  • XL150: 2 x 330lbs [2 x 150kg]
  • XL80: 2 x 176lbs [2 x 80kg]

Product Usage Instructions

Installation Instructions

1. Overall

These instructions are for installing the MUTO PREMIUM sliding
door system XL150/80 with Sidelites for Wood doors in a ceiling
mount configuration.

2. Door/Wall Dimensions

Ensure the dimensions of the door and wall meet the requirements
specified in the manual.

3. Installing the End Stops

Follow the provided steps to properly install the end stops for
the sliding door system.

FAQ

Q: What is the weight capacity of the XL150 and XL80

models?

A: The XL150 model has a door leaf weight capacity of 330lbs
(150kg), while the XL80 model can support up to 176lbs (80kg).

Q: How should I support the door panel during installation to

prevent glass breakage?

A: When installing the door, make sure to support the door panel
with a block of wood or similar object to avoid the risk of
breaking glass.

“`

MUTO Premium XL150/80
Ceiling mount with Dormotion and Sidelites (Wood door)
Installation Manual
936058 – 11/2023 Original document
EN

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
Table of contents

Table of Contents

1 Technical specifications

3

1.1 Overview

3

1.1.1 General information

3

1.1.2 Intended use

3

1.1.3 Glass requirements and fittings

3

1.1.4 Requirements for glass panel

3

1.1.5 Safety instructions

3

1.1.6 Symbols used – Safety/Installation

3

1.1.7 Maintenance, care, repair

3

1.1.8 Disposal

3

1.2 Specifications – technical data

4

2 Installation instructions

5

2.1 Overall

5

2.2 Door/wall dimentions

6

2.3 Installing the end stops

7

2.4 Securing gasket to track

7

2.5 Securing track and sidelite section

profile to mounting surface

8

2.6 Installing U-channel for sidelite

8

2.7 Installing sidelite glass

9

2.8 Installing sidelite glass filler panel

9

2.9 Installing sidelite glass gasket

10

2.10 Securing wood door adaptor

10

2.11 Installing the roller carriers

11

2.12 Install DORMOTION start/stop

12

2.13 Disengaging the anti-jump

13

2.14 Install door/rollers in track

13

2.15 Install floor guide

14

2.16 Engaging anti-jump

14

2.17 Adjustment door height

15

2.18 Adjustment end stop location:

TRAILING end stop

16

Adjustment end stop location:

LEADING end stop

16

2.19 Install DORMOTION units

17

2.20 Adjust start/stop pin height (if necessary) 19

2.21 Cover clips

20

2.22 Cover spacers

20

2.23 Install brush profile

21

2.24 Install view protection clips

21

2.25 Install cover and view protection profile

22

2.26 Install end caps

22

2

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
1 Technical specifications

Technical specifications

1.1 Overview
These instructions are for installation of MUTO PREMIUM sliding door system XL150/80 with Sidelites for Wood doors for the following mounting and style versions:
1. Ceiling mount
1.1.1 General information · dormakaba requires use of tempered monolithic or
tempered laminated glass. · dormakaba glass hardware is not suitable for
application in rooms where chemicals (e.g. chlorine) are used as indoor swimming pools, saunas or salt-water pools. · Never move sliding panels faster than walking speed and always stop the door manually before it reaches end position. · Do not slide doors with excessive force. Install limiting stop to prevent door from opening too far.
1.1.2 Intended use · For sliding door in dry indoor areas only · For manual slowly opening and closing only

· Only properly qualified and specially trained staff are authorized to mount dormakaba glass hardware.
· Due to crushing hazards and possible injury caused by breakage of glass during mounting, corresponding protective clothing (especially gloves and protective goggles) is required.
· Never clamp metal fitting hardware directly to glass surface.

1.1.6

Symbols used – Safety/Installation CAUTION

Mounting components must meet the requirements of substructure/wall and door weight. Please read the technical information for fittings.

WARNING
Risk of breaking glass. When installing the door, support the door panel with a block of wood or similar object.

1.1.3 Glass requirements and fittings · The substructure/wall must be able to bear
permanent loads and be level (max. tolerance: 1/16″ [2] per 39″ [1m]). · Fasteners must be sufficiently dimensioned for the substructure/wall and weight of the door. · When adjusting glass components, always stick to the required clearance for the respective hardware. Adjust clearance so glass does not come in contact with any hard surfaces such as glass, metal or concrete. · Do not use excessive force when installing the glass (avoid over tightening screws).
1.1.4 Requirements for glass panel · dormakaba requires use of fully tempered glass,
which complies with ASTM C 1036 and ASTM C 1048. Secondary heat soaking processes are recommended but not required. This applies to both tempered monolithic and tempered laminated glass. · Clamping area must be flat and uncoated (no self-cleaning coating!) · Never use glass with conchoidal fractures and/or damaged edges.
1.1.5 Safety instructions · Installation requires two people.

TIPS AND RECOMMENDATIONS
Information note
CLOSING EDGE
1.1.7 Maintenance, care, repair · Immediately replace damaged parts. · Always use original dormakaba parts. · Clean clamping area with alcohol-based standard
commercial cleaning agent before mounting the glass hardware. · Use a damp clothe for occasional cleaning, especially the track. · Always use silicone – and oil-free cleaners (e.g. acetone). · Check glass hardware at regular intervals for proper positioning and smooth operation and correct adjustment. · High traffic door systems require inspection by properly qualified staff (specialized companies or installation firms.)
1.1.8 Disposal Disposal in accordance with local, state and national regulations.

MUTO Premium

936058

11-2023

3

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions

1.2 Specifications – technical data

Ceiling mount

Single Door

XL150

Door leaf weight lbs [kg] *

330lbs [150]

  • Including weight of auxiliary hardware.

XL80
176lbs [80]

Double Door

XL150

XL80

2 x 330lbs 2 x 176lbs [2 x 150] [2 x 80]

Technical specifications

4

MUTO Premium

936058

11-2023

5

11-2023

936058

MUTO Premium

1.1 1.2 1.3 1.4

1.5 1.6

1.12 1.10 1.8 1.11
1.18

1.1

Cover panel

1.2

Brush strip

1.3

Track

1.4

Cover end cap

1.5

Sidelite profile

end cap

1.13

1.6 1.7 1.8 1.9 1.10

Filler profile Sidelite profile End stop Cover clips Dormotion unit

1.14

1.11 1.12 1.13 1.14

Roller carrier Start/stop Floor guide U-channel

1.15
1.16 1.7 1.9 1.17 1.10 1.8

1.15 1.16 1.17 1.18

Sidelite glass gasket View protection profile View protection clip Wood door adaptor

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2 Installation instructions
2.1 Overall

Overall

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.2 Door/wall dimentions
Single sidelite mount

clear opening
height (CH)
(DW) Wood door panel

(SW)
Sidelite glass

1-3/16″ [30]

1-3/16″ [30]

Technical specifications

Back of track to center of mounting
hole in track

7/8″ [23]

Multiple sidelite mount

clear opening width (CW)

clear opening
height (CH)

1/2″ Bottom of 3/8″ [13] door to floor [10]

Back of track to center of mounting
hole in track

7/8″ [23]

(SW) Sidelite
glass
1-3/16″ [30]

(DW)
Wood door panel

(SW2) Sidelite
glass
1-3/16″ [30]

clear opening width (CW)

1/2″ Bottom of 3/8″ [13] door to floor [10]

6

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions

End stops Track

NOTE: Overhead Reinforcement: The overhead reinforcement must be a minimum of ¼” [6] x 3″ [76] steel angle, 16 gauge metal stud, or two pieces of 1 1/2″ [38] thick wood blocking (double stacked), secured to studs or joists on a maximum 16″ [406] centers for the length of the track. The overhead reinforcement may be flush on the overhead surface or on the interior of this surface.

Track mounting screws must fully penetrate the steel angle, metal stud, or at a minimum of 2″ [51] into wood blocking, utilizing the predrilled holes in the MUTO track.
Consult with a structural engineer to determine if reinforcement is adequate for your specific application or to meet specific codes in your location.

2.3 Installing the end stops
Fig 1

Set screw

Track

Hex key size XL150/80 3mm

End stops
2.3.1 Slide bumper stops into each end of the track. NOTE: Loosen bottom section of end stop for easier install.

Bottom section of bumper
NOTE: FOR XL150 end stops, be sure set screw is flush with back of bumper. NOTE: Exact location/adjustments will be determined in the Adjustment End Stop Location step.

2.4 Securing gasket to track
Fig 2
Track

Adhesive gasket
2.4.1 Ensure the track is cut to proper length. NOTE: SEE DIMENSION INSTRUCTIONS ON PAGE 6.

Sidelite glass

2.4.2 2.4.3

Cut adhesive gasket equal to sidelite glass width. Adhere gasket along bottom edge of back of track.

MUTO Premium

936058

11-2023

7

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood)

Track

Installation Instructions

Sidelite profile

U-channel
2.5 Securing track and sidelite section profile to mounting surface

Fig 3

Track

Sidelite profile

2.5.1 Secure track to mounting surface. 2.5.2 Align predrilled holes in sidelite profile with track
profile. NOTE: Holes will be predrilled every 7-7/8″ [200].

2.5.3 Secure with proper fasteners.
NOTE: Be sure fasteners are flush with track to avoid rollers catching protruding fasteners.

2.6 Installing U-channel for sidelite
Fig 4
U-channel gasket

Orient gasket(s) as shown.
2.6.1 Install gaskets as shown. Trim to correct length. 2.6.2 Secure u-channel to floor using appropriate
fasteners.

U-channel
NOTE: Ensure u-channel is plumb and the back of the u-channel profile aligns with back of sidelite profile.

8

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.7 Installing sidelite glass
Fig 5
Sidelite profile

Sidelite glass Sidelite filler panel

Sidelite glass
U-channel setting blocks

Lift up into sidelite profile

U-channel

Lower down into u-channel

1/8″ gap

Sidelite glass

Sidelite glass

Wall

2.7.1 Place setting blocks into u-channel.

2.7.5 Ensure there is 1/8″ [3] gap between wall and

2.7.2 Spray inside of u-channel with glass cleaner.

edge of sidelite glass.

2.7.3 Lift glass up and into sidelite profile.

2.7.6 If using tempered laminated glass, gently press

2.7.4 Lower glass into u-channel.

glass panel against u-channel gasket and

dispense silicone along full length of non-gasket

side of U-channel.
2.8 Installing sidelite glass filler panel

Fig 6

Track

Sidelite glass

Filler panel

2.8.1 Fit filler panel in to gap of door panel section in sidelite profile.

MUTO Premium

936058

Sidelite profile

11-2023

9

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.9 Installing sidelite glass gasket
Fig 7

Sidelite glass gasket Wood door adaptor

Sidelite gasket
2.9.1 Cut gasket to length per chart above.

Sidelite profile
Sidelite gasket location

Sidelite glass

2.9.2 Press gasket in between sidelite glass and sidelite profile.

2.10 Securing wood door adaptor
Fig 8

XL150/80

XL150/80

Wood door adaptor

Every 4th hole

Every

Every

4th hole 4th hole

Every 4th hole

1/2″ [13]

Wood door

NOTE: Top of door must be reinforced to secure wood door adapter.
2.10.1 Prepare door properly for wood door adaptor.
NOTE: Seal top and bottom of door to minimize warping (use wood door manufacturer’s recommendations).

2.10.2 Cut wood door adapter to be equal width of door.
2.10.3 Secure the two wood door adaptor pieces to top of wood door with #10 x 3″ wood screws.
NOTE: Be sure screws are always secured in the first four and last four holes of the adaptor, along with every fourth hole in between.

10

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.11 Installing the roller carriers
Fig 9
DETERMINE THE LEADING (X) VERSUS TRAILING (Z) EDGE OF THE GLASS. “LEADING IS SIDE CLOSEST TO LATCH CLOSED.”
Z

Roller carriers X

Secure

Roller location on wood door with DORMOTION unit

XL150/80

Single door X

3-1/8″ [80]

Double door X

1-9/16″ [40]

Single door Z

1-9/16″ [40]

Double door Z

2-3/8″ [60]

Roller carrier

Legend Closing edge of door
Torque values XL150/80 10ft lbs
[14Nm] Hex key size XL150/80 4mm

(Front of) Wood door

(Front of) Wood door

NOTE: FULLY CLEAN SURFACE OF ADAPTOR WITH AN ALCOHOL-BASED MILD GLASS AND SURFACE CLEANER. ENSURE GASKET IS FREE OF DEBRIS. ENSURE ROLLER CARRIER WHEELS ARE FREE OF DEBRIS.

2.11.1 Slide roller carriers onto wood door adaptor.
2.11.2 Slide gasket and metal shim between adaptor and roller carrier.

NOTE: Orient with gasket facing the adaptor.
2.11.3 Secure roller carriers to wood door adaptor using appropriate-size hex key at 10ft lbs (14 Nm).

MUTO Premium

936058

11-2023

11

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.12 Install DORMOTION start/stop
Fig 10

PRODUCT SHIPPED WITH 7/8″ [22] PIN INSTALLED. PIN CAN BE CHANGED TO 1″ [25] IF NECESSARY.

Start/stop pin

Images not to scale

Hex screws

7/8″ [22] =

1″ [25] =

Start/stop

Torque Set screws

3 ft lbs [3 Nm]

Hex key size Set screws 3 mm Hex screws 3 mm

Set screws

Start/stop

Glass gasket

NOTE:
2.12.1 · · · ·

Determine a pin length based upon how square and plumb the opening is. If required, change pin in start/stop assembly. Remove hex screws. Remove existing pin and plate. Swap in appropriate pin and plate. Replace hex screws.

2.12.2 2.12.3 2.12.4
NOTE:

Slide start/stop onto glass. Center equally between the carriers. Slide glass gasket between start/stop and glass. Orient with gasket facing glass.

2.12.5 Secure start/stop via set screws.

12

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.13 Disengaging the anti-jump
Fig 11

1/4 turn

Antijump

Anti-jump Track

Antijump
NOTE: Anti-jump shipped engaged.
2.13.1 Disengage the anti-jump on roller carrier.

Anti-jump adjustment screw
Hex key size XL150/80 4mm
NOTE: Using the appropriate-size hex key, push antijump adjustment screw IN and turn COUNTERCLOCKWISE 90° to disengage anti-jump.

2.14 Install door/rollers in track
Fig 12

ENSURE ROLLERS AND TRACK ARE FREE OF DEBRIS.

2.14.1 Tip wood door and rollers upward and rest rollers on track.

MUTO Premium

936058

11-2023

13

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.15 Install floor guide
Fig 13

Wood door

Wall

Sidelite glass
5/16″ [7]

Wood door

Floor guide Anti-jump

=

=

Floor guide
U-channel

2.15.1
2.15.2 2.15.3

REMEMBER ANTI-JUMP IS DISENGAGED! Temporarily slide floor guide into bottom groove of wood door. Be sure the door is plumb. Mark appropriate floor guide measurements.

Floor guide

1-1/[43″2]

2.15.4
2.15.5 2.15.6 2.15.7

TEMPORARILY REMOVE WOOD DOOR AND ROLLERS FROM TRACK (TO ALLOW FOR DRILLING SPACE).
Pre-drill into mounting surface using a 5/16″ drill bit.
Secure floor guide with included fasteners.
SET WOOD DOOR AND ROLLERS BACK ONTO TRACK.

2.16 Engaging anti-jump
Fig 14
1/4 turn

Antijump

Anti-jump adjustment screw

2.16.1 Engage anti-jump on roller carrier.

Antijump
Hex key size XL150/80 4mm
2.16.2 Using appropriate-size hex key, push anti-jump adjustment screw IN and turn CLOCKWISE 90° to engage anti-jump.

14

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions

Height adjustment

2.17 Adjustment door height
Fig 15

5/16″ [7] =
U-channel

+3/16″ [5] -3/16″ [5] Wood door =

Door height adjustment tolerance
XL150/80
+3/16″ [+5] -3/16″ [-5]

3/8″ [10]

Height adjustment
screw

Height adjustment locking screws

Torque XL150/80

10 ft lbs [14 Nm]

Hex key size XL150/80 4mm

2.17.1 Set height of glass door. 2.17.2 Loosen height adjustment locking screws of
carrier.

2.17.3 Using appropriate-size hex key, turn height adjustment screw CLOCKWISE or COUNTERCLOCKWISE to raise or lower door.
NOTE: Be sure wood door is level during this adjustment.

MUTO Premium

936058

11-2023

15

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.18 Adjustment end stop location: LEADING end stop
Fig 16

0mm

END STOP LOCATION: LEADING EDGE

NOTE: bi-folding: Be sure there is a 1/4″ [6] gap between the right and left hand sets.

End stops
Hex key size XL150/80 3mm

End stop

Bumper

Door overlap on wall
max. 1-3/16″ [30] Wood door edge
Jamb edge

Edge of roller carrier
Door pull

Door closed

Door pull to jamb distance. Verify with local jurisdiction.

Torque XL150/80

3 ft lbs [4 Nm]

Set end stop locations: 2.18.1 Slide end stop
to desired location on track. Bumper should touch edge of roller carrier.
Bumper
Secure

Fig 17

Adjustment end stop location: TRAILING end stop

0mm

END STOP LOCATION: TRAILING EDGE

NOTE: bi-folding: Be sure there is a 1/4″ [6] gap between the right and left hand sets.

Hex key size XL150/80 3mm

Edge of roller carrier
Wood door edge

End stop Bumper
Jamb edge

Door opened

Door pull
Door pull to jamb distance. Verify with local jurisdiction.

Torque XL150/80

3 ft lbs [4 Nm]

Set end stop locations: 2.18.1 Slide end stop
to desired location on track. Bumper should touch edge of roller carrier.
Bumper
Secure

16

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions

Dormotion unit

2.19 Install DORMOTION units

Fig 18

Fig. 18.1 RH DM unit

Fastening plate

DM end stop

Hook

Fig. 18.2 RH DM unit fastening plates rotated

RH Dormotion -door closed

2.19.1 Rotate RH DM fastening plates.

·

Using 4 mm hex key, loosen

fastening plate hex screws.

·

Rotate fastening plates until they

are parallel to the DM unit (Fig. 18.2)

·

Snug hex screws.

2.19.2 ·

Move door to close position. For installation of RH DM unit, door must be in the closed position against bumper.

Fig. 18.7 RH DM unit aligned in track

Fig. 18.3 RH DM unit inserted in track
DM unit DM trigger block

Door closed
Fig. 18.4 DM unit hook positioned in trigger
DM hook DM end stop

Trigger

Roller carrier Bumper
RH DM unit

Door closed

Fig. 18.5 DM unit end stop and hook separation adjustment

Adjustment tool Fork

Fork gap DM end stop

DM hook Trigger

Bumper RH DM unit

Door closed

Fig. 18.6 RH DM unit fastening plates secured in track

Plates rotated

Fastening plates

SHCS

SHCS

2.19.3 Align DM unit in track, engage DM hook in DM trigger.

·

Align DM unit in track (Fig. 18.7).

·

Slide DM unit over the DM trigger

block until the DM hook engages

the DM trigger (Fig. 18.4)

2.19.4 · · ·

Use adjustment tool to set DM unit final position. Place adjustment tool flat against DM unit with fork between DM hook and DM end stop (Fig. 18.5). Slide DM unit over until hook and DM end stop are against the fork. This sets 5 mm gap (fork gap). Trigger height: Adjust so trigger sets on top of adjustment tool (Para. 2.19).

2.19.5 Secure the DM unit in position.

·

NOTE: Insure door is fully closed

against bumper before performing

this step.

·

Using 4 mm hex key, tighten DM

unit fastening plate socket head

cap screws . Fastening plates must

engage the track (Fig. 18.6 and .8).

Torque Socket head cap screws 3 ft lbs [4 Nm]

Fig. 18.8 RH DM unit installed in track

Plates rotated

MUTO Premium

936058

11-2023

17

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
Fig. 18 (Con’t) Fig. 18.9 LH DM unit
Fastening plate

Hook

DM end stop

Fig. 18.10 LH DM unit fastening plates rotated

Dormotion unit

LH Dormotion -door open 2.19.6 Rotate DM fastening plates.

·

Using 4 mm hex key, loosen

fastening plate hex screws.

·

Rotate fastening plates until they

are parallel to the DM unit (Fig. 18.10)

·

Snug hex screws.

2.19.7 Move door to open position.

·

For installation of LH DM unit, door

must be in the open position

against bumper.

Fig. 18.15 LH DM unit aligned in track

Fig. 18.11 LH DM unit inserted in track

LH DM unit

DM trigger block

Door open

Fig. 18.12 DM unit hook positioned in trigger

Trigger

DM hook DM end stop

Roller carrier Bumper

LH DM unit

Door open

Fig. 18.13 DM unit end stop and hook separation adjustment

Adjustment tool Fork

DM hook Trigger

Fork gap DM end stop

LH DM unit

Bumper

Door open

Fig. 18.14 LH DM unit fastening plates secured in track

Plates rotated

Fastening plates

SHCS

SHCS

2.19.8
· ·

Align DM unit in track, engage DM hook in DM trigger. Align DM unit in track (Fig. 18.15).
Slide DM unit over the DM trigger block until the DM hook engages the DM trigger (Fig. 18.12)

2.19.9 ·
·
·

Set DM unit final position.
Place adjustment tool flat against DM unit with fork between DM hook and DM end stop (Fig. 18.13). Slide DM unit over until hook and DM end stop are against the fork. This sets 5 mm gap (fork gap). TTrigger height: Adjust so trigger sets on top of adjustment tool (Para. 2.19)

2.19.10 Secure the DM unit in position.

·

NOTE: Insure door is fully open

against bumper before performing

this step.

·

Using 4 mm hex key, tighten DM

unit fastening plate socket head

cap screws . Fastening plates must

engage the track (Fig. 18.16).

Torque Socket head cap screws 3 ft lbs [4 Nm]

Fig. 18.16 LH DM unit installed in track

Plates rotated

18

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.20 Adjust start/stop pin height (if necessary)
Fig 19

Hex screw

Hex screw

Start/stop

Start/stop pin

2.20.1
· ·

Adjust HEIGHT of start/stop

pin, if necessary:

Loosen hex screws.

Slide pin and plate up or down.

Hex key size

Hex

3 mm

screws

CORRECT PIN HEIGHT/ ORIENTATION

MUTO Premium

936058

11-2023

19

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.21 Cover clips
Fig 20

Cover clips Cover spacers

Cover clip

2.21.1 Insert cover clips into track. (One clip per foot)

2.21.2 Insert perpendicular to track, and turn CLOCKWISE to snap into place.

2.22 Cover spacers
Fig 21

Cover spacer

2.22.1 Tip cover spacers into outter most edge of track.

Cover spacer

Hex key size

XL150

2.5mm

2.22.2 Place one at each end of track as shown. 2.22.3 Tighten at at 1 ft lbs [1Nm] or hand tighten.

20

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.23 Install brush profile
Fig 22
Cover

Brush profile View protection clips

Brush

2.23.1 Measure and cut brush to appropriate length.

2.23.2 Slide brush into cover.

2.24 Install view protection clips
Fig 23
TO BE USED WITH ONE OR MULTIPLE SIDELITE APPLICATIONS.

Empty sliding portion of track

(Slide door panel) Door panel

Sidelite glass
View protection profile

View protection clips

View protection clip

Cover

2.24.1 2.24.2
2.24.3

Slide door open until it meets the end stop. Measure and cut view protection profile to fit into empty sliding portion of track – 3/16″ [5]. Snap view protection clips onto inside of cover as shown.

2.24.4 Use minimum 1 clip per foot of profile.
Exception: If profile is minimum of 1 foot in length, use 2 clips.

MUTO Premium

936058

11-2023

21

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions
2.25 Install cover and view protection profile
Fig 24

Cover

View protection clip and profile removed for easier viewing of cover
installation.

Cover View protection profile
End caps
Cover clip
Cover

View protection profile
Cover
2.25.1 Secure cover to clips and snap into place. NOTE: Roll cover from the bottom upwards. Ensure the bottom of the cover is supported by the groove in the cover clip.
2.26 Install end caps
Fig 25

View protection clip

NOTE: WOOD DOOR ADAPTOR NOT SHOWN IN IMAGES

View protection profile

Cover

2.25.2 Tip view protection profile up into track and snap down into cover and onto track as shown.

Sidelite profile end cap

Sidelite profile end cap

Cover end cap

Cover end cap

2.26.1 Snap sidelite profile end caps into sidelite profile.

2.26.2 Snap end caps into cover.

22

MUTO Premium

936058

11-2023

dormakaba MUTO XL150/80 Ceiling Mount with Dormotion with Sidelites (Wood) Installation Instructions

Blank page

This page left intentionally blank.

MUTO Premium

936058

11-2023

23

Scan for product details and downloads. Call 800-523-8483 or visit glasstechserv.us@dormakaba.com for assistance or warranty information

dormakaba USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

dormakaba User Manuals

Related Manuals