Specifications
- Switch Mode: Momentary Action * SPDT N/O or N/C
- Switch Rating: 10A @ 250V
- Finish: Beige (plastic)
- Conversion: Surface-mounted switches only may be converted to Maintained Switch Mode
Product Usage Instructions
909 Surface Mount Instructions
- Remove the decorative bezel around the switch.
- Optional: To convert the momentary switch provided to maintained switch mode, carefully remove the spring located under the rocker switch with a small screwdriver or pliers.
- Mount the switch base in the desired location.
- Connect wires under appropriate terminals (refer to Fig. 1).
- Replace decorative bezel.
909 Flush Mount Instructions
- Pry off the decorative bezel around switch and remove toggle.
- Cut a 2-1/4 x 1-1/4 hole in the drywall.
- Connect wires under appropriate terminals (refer to Fig. 2).
- Insert the switch into hole. Tighten the two metal slot screws until the switch is secure.
- Replace the toggle and decorative bezel.
FAQ
- Q: Can the surface-mounted switches be converted to Maintained Switch Mode?
- A: Yes, surface-mounted switches can be converted to Maintained Switch Mode by following the provided instructions to remove the spring located under the rocker switch.
- Q: What are the contact configurations of the switch?
- A: The switch has N/C (Normally Closed), N/O (Normally Open), and C (Common) contact configurations for power out and power in operations.
SURFACE MOUNT INSTRUCTIONS
- Remove decorative bezel around switch. Optional: * To convert the momentary switch provided to maintained switch mode, carefully remove the spring located under the rocker switch with a small screwdriver or pliers.
- Mount switch base in desired location.
- Connect wires under appropriate terminals (Fig. 1).
- Replace decorative bezel.
FLUSH MOUNT INSTRUCTIONS
- Pry off the decorative bezel around switch and remove toggle.
- Cut a 2-1/4” x 1-1/4” hole in the drywall.
- Connect wires under appropriate terminals (Fig. 2).
- Insert switch into hole. Tighten the two metal slot screws, until switch is secure.
- Replace toggle and decorative bezel
NOTE: Specifications are subject to change without notice.
N/C – Normally Closed, N/O – Normally Open, C – Common
- Surface-mounted switches only may be converted to Maintained Switch Mode.