1. Product description
1.2 Overview
Modern finish design ,8-inch LCD Touch screen . High-speed processing and a large storage capacity make the terminal a powerful range: 1:30,000 user identification is carried out in 1 second.
Technology & Function:
The dormakaba 91 60-K5 Face Recognition Terminal can be easily integrated into
building structures. It has large screen ratio which supports 1:N or 1:1 face
authentication .
The devices embed a web server enabling on-device enrollment, terminal
configuration and transaction log retrieval. For scenarios requiring the use
of contactless cards, the series also features multiple card reader or QR code
reader
1.2 Technical Data
1.2.1 System
linux: gcc-arm-8.3-2019.03-x86_64-arm-linux-gnueabihf
1.2.2 Operating mode
Connect Discern Software for online or standalone.
1.2.3 RFID/Temperature Measurement
- RFID Reader Only(Legic&Mifare)
- RFID Reader with QR Code (Legic&Mifare)
- QR Code Only.
- Infrared Imaging Temperature Measurement Set
1.2.4 Power supply
- Rated voltage: 12V DC 1.8A
1.2.5 Inputs/outputs
- Network* 1
- USB* 1
- Tamper* 1
- Wiegand* 1
- Realy output 1 Input Single 2
1.2.6 Ambient conditions
- Operat ing temperature: -20℃ ~ + 70℃
- Relat ive humidity: 10% – 90% (non-condensing)
- Waterproof level: IP66
1.2.7 Dimensions
All dimensions in mm.
- 237mmL x 133mmW x20.8mmH
- Wall dimension drawing
Mounting dimensions of bracket without temperature measurement
Dimension drawing of module with temperature measurement
Mounting dimensions of bracket with temperature measurement
1.4 Featrue structure
- Infrared fill light
- RGB Camera
- Infrared Camera
- Indicator feedback signal
- Infrared sensor module
- 8 Inch Touch Screen
- Card reading area
- Bottom fixing screw
- Bottom fixing screw wiring
- Backplane fixing screw
- Temperature measurement module
1.4 Labeling
The identification plate is located on the underside of the device.
The identification plate contains:
- Device name
- Item number
- Serial number
- Connection data (power supply)
2 Installation
2.1 Installation Lines
2.1.2 Power Supply Cable
Power is normally supplied to the 9160 terminal by the seperate power supply.
In case of long lines, the voltage drop due to line resistance will need to be
considered.
2.1.2 Data lines
Recommended cable: CAT.5 or higher.
Data transmission is mainly network data transmission.
2.1.3 Connections
Recommended cable: RVVP 2* 1.0 or higher.
The following connect ions should be present at the installat ion locat ion:
- Ethernet cable, with RJ45 plug
- Power supply cable
- Lines to electric strikes and opener key.
- Lines to the Wiegand Interface
PRODUCT WIRING
Electric Lock Wiring
Note: The combination of NO and COM is normally open,while that of NC and COM is normally closed.The main equipment needs to use our power supply for independent power supply.
3. Start-up and commissioning
3.1 Start-up
Start-up and communication in regular operation are done via an Ethernet
network. Power Suppply: DC12V 1.8A
The firewall configuration must therefore be adapted accordingly.
Without temperature measurement
With temperature
3.2 System Activation and login
System-specific settings, connection settings, such as assignment of a fixed IP address, can be made via the 91 60 system settings.
Activate the 91 60 system settings
1. Start the terminal.
2. If the 9160 is started for the first time, the system prompts you to
activate it.
3. After the startup is complete, the main activation screen is displayed.
Step 1: The first login screen will prompt you to set the language to be used
Step 2: Set the account and password, enter the account password you need to set
Step 3: Set up network configuration
Step 4: User mode:default is Access mode. Attendance mode is currently disabled.
Management mode:
Server mode is to use software to configure the device(for example DISCERN)
Standalon mode is the local configuration device
Server IP and account is the configured server connection address and account
information
3.3 Device Local Management
Local Settings contain device parameters and some local configuration.
1. Personnel management
2. Logbook
3. Face Control
4. Parameter Setting
5. Peripherals
6. About
Login the 91 60:
In the upper right corner of the 91 60 screen, hold down the screen. The login
screen is displayed. Enter your account and password to enter the main screen
3.3.1 Personnel management
The personnel management mainly consists of the locally add personnel photo , the local badge number and the output of Weigen number
1. The action menu is displayed after successful login and select the Personnel management
3.3.2 Logbook
Logbook mainly display local access log and system log and exception log 1.The action menu is displayed after successful login and select the Logbook
3.3.3 Face Control
Face Control is includes Face algorithm and access control interface Settings
- The action menu is displayed after successful login and select the Face Control
Input 1: Set the door sensor fuction is enable.
Input 2 function is not available at present
Input 3 function is not available at present
3.3.4 Parameter Setting
Parameter Settings include Customer setting and Communicationsetting and
Universal setting The action menu is displayed after successful login and
select the Parameter Settings
3.3.4.1 Customer Parameters
3.3.4.2 Communication Settings
3.3.4.3 Universal Settings
3.3.4.1 Customer Parameters
Customer Parameters include Basic settings and Display Settings
1.The action menu is displayed after successful login and select the Parameter Settings–Customer Parameters
3.3.4.2 Communication Setting
Communication Settings mainly include IP address and communication interface
server address Settings
1.The action menu is displayed after successful login and select the Parameter Settings– Commnication setting
3.3.4.2 Communication Setting
Communication Settings mainly include IP address and communication interface
server address Settings
1.The action menu is displayed after successful login and select the Parameter
Settings–
Commnication setting
3.3.4.3 Universal Parameters
Universal Parameters include the local language, NTP server Settings
1.The action menu is displayed after successful login and select the Parameter Settings–Universal Parameters
3.3.5 Peripherals
Peripherals mainly include how to enable and configure the temperature measurement function.
1.The action menu is displayed after successful login and select the Peripherals–Temperature Parameters
3.3.6 About
About mainly include About includes basic device information (model, serial
number, and MAC address), APP update, and firmware upgrade.
3.3.6.1 Basic Device Information
Basin Device Information includes: Device model, serial number, MAC address, device version, and activation code information.
1.The action menu is displayed after successful login and select the About.
3.3.6.2 Modify activation
Use activated device purpose
1.The action menu is displayed after successful login and select the About–Modify activa
The device is delivered with an activation code. If the device does have an activation code, you need to contact the manufacturer to obtain the activation code and enter the activation code to activate the device while keeping the device connected to the Internet
3.3.6.3 Update
Update the 91 60 APP version
1.The action menu is displayed after successful login and select the About-
Update
Update:
Steps to update your APP
1.Copy the attachment “xxxxx.tar.gz” to the root directory of U disk
2.Rename xxxxx.tar.gz to “update_app.tar.gz” on your USB drive
3.Insert the U disk into the USB interface of the 9160
4.Keep touching the upper right corner of 9160 to display the login interface
(Enter the account and password for initializing the device for the first
time)
5. About–Update
Note:You can update APP versions with interfaces (e.g. DISCERN and third-party interface software)
3.3.6.4 Firmware Upgrade
Upgrade the 91 60 firmware version
1.The action menu is displayed after successful login and select the About- Firmware Upgrade
Firmware Upgrade:
Steps to update your firmware
1. Copy the attachment “xxxxx.img” to the root directory of U disk
2. Rename xxxxx.img to “update.img” on your USB drive
3. Insert the U disk into the USB interface of the 9160
4. Keep touching the upper right corner of 9160 to display the login
interface (Enter the account and password for initializing the device for the
first time)
5. About–Firmware Upgrade
Note: After the firmware is updated, the device needs to be reactivated. Please back up the activation code of the device
3.3.6.4 Restore the factory
Restore factory Settings will clear the local Settings and account information
1.The action menu is displayed after successful login and select the About- Restore factory
Restore factory:
Restore factory Settings will clear all data of the 91 60, and you need to initialize the device to set the account and password of the 91 60.
3.3.6.5 Restore default
Restore Default will Clear user Settings and restore the device to factory default Settings.
1.The action menu is displayed after successful login and select the About- Restore default.
Restore default:
Restore Default Settings Clear user Settings and restore the device to factory
default Settings.
4. Troubleshooting
Trouble List | Solution |
---|---|
No Response when Power Up |
- Discount the power and confirm that the power supply cable is correctly connected (See “Wiring” above).
- Check the input voltage is sufficient (See “Specifications” above).
Auto Restart|
- Check the input voltage is sufficient (See “Specifications” above).
Cannot read card number correctly|
- Check the format setting on the controller if it is the same as the card format. Use approved card (known format and Facility Code) to test.
- Check if the shield cable is correctly connected to Classis Ground at ONE point only.
Reader beeps but No card data info|
- Check if data 0 & data 1 cable is correctly connected (See “Wiring” above).
- Check the input voltage at the card reader end is correct (See “Specifications” above).
Specifications
-
System: Linux:
gcc-arm-8.3-2019.03-x86_64-arm-linux-gnueabihf -
Operating Mode: Connect Discern Software for online or standalone
-
RFID/Temperature Measurement: Included
-
Power Supply: Not specified
-
Inputs/Outputs: Not specified
-
Ambient Conditions: Not specified
-
Dimensions: Details available in the user manual
FCC Statement
Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
RF warning for Portable device:
The device has been evaluated to meet general RF exposure requirment. The
device can be used in portable exposure condition without restriction.
Note : This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,uses and
can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FAQ
Q: What should I do if the terminal does not recognize my face?
A: If the terminal does not recognize your face, ensure that you are positioned correctly in front of the camera and that there is adequate lighting. You may also need to re-enroll your face in the system.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>