ERMENRICH DS20 Digital Sound Level Meter User Manual

June 13, 2024
ERMENRICH

ERMENRICH DS20 Digital Sound Level Meter

ERMENRICH DS20 Digital Sound Level Meter

Overview

  1. Protection cover
  2. Windscreen
  3. Microphone
  4. LCD
  5. MAX/MIN button
  6. °C/°F button
  7. F/S (Fast/slow) button
  8. Data hold/Backlight button
  9. Power button
    Overview

Ermenrich Seek DS20 Digital Sound Level Meter

Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.

The kit includes : digital sound level meter, pouch, user manual, and warranty card.

Getting Started

  • Unscrew the screw on the back of the sound level meter, remove the battery compartment cover, and insert 3 AAA batteries. Close the cover and screw in the screw.
  • Press the Power button and hold it for two seconds to turn on the device.
  • Press the Power button to turn off the device

Display Information

  1. Automatic shutdown mode
  2. Data hold mode
  3. Maximum value mode
  4. Minimum value mode
  5. Low battery indicator
  6. Relative humidity unit (percentage)
  7. Relative humidity value
  8. Slow time weighting
  9. A-weighted value
  10. C-weighted value
  11. Sound level unit (decibels)
  12. Sound level value
  13. Sound level scale
  14. Fast time weighting
  15. Temperature unit (degrees Celsius)
  16. Temperature value
  17. Temperature unit (degrees Fahrenheit)
    Display information

Operation

During the measurement, keep the microphone faced towards the noise source. Wind blowing across the microphone may distort the measurement results. Cover the microphone with the windscreen (included) when in operation. The value of the noise measurement is shown in the field [12] on the display and on the graphical scale [13].
When the unit is not in use, cover the microphone with a protective cover and pack the unit in a special pouch (cover and pouch included).

Automatic shutdown function

The sound meter automatically turns off after 10 minutes from the last action. The automatic shutdown icon [1] on the display indicates that this mode is currently active.

To turn on the sound level meter without using the automatic shutdown function, press the Data hold/Backlight button and the Power button simultaneously. To restore the automatic shutdown function, turn the meter off and on again.

MAX/MIN Measurement

Pressing the MAX/MIN button once sets the device into the MAX mode [3]. In the MAX mode, the device shows the maximum data value during the current measurement cycle.
Pressing the MAX/MIN button twice sets the device into the MIN mode [4]. In the MIN mode, the device shows the minimum data value during the current measurement cycle.
To exit the MAX/MIN measurement modes, press the MAX/MIN button and hold it for 2 seconds.

 FAST/SLOW time Weighting

Press the F/S button to choose between fast (125ms) and slow (1s) time weighting modes. The display shows either FAST [14] or SLOW [8] icon, depending on which mode is currently selected.
Select fast time weighting mode to capture noise peaks and quick-emerging noises. This mode is suitable for most applications.
Select slow time weighting mode to monitor sound sources with consistent noise levels and average out the quickly changing noises.

Data Hold Mode

Press the Data hold/Backlight button to hold the current measurement values on the display. The Data hold icon [2] will light up on the display. In the Data hold mode, the device will show the last recorded sound, temperature, and humidity measurement values on the display.
To exit the Data hold mode, press the Data hold/Backlight button again.

Display Backlight

Press the Data hold/Backlight button for two seconds to turn the display backlight on or off.

Relative Humidity Measurement

The sound level meter is equipped with a relative humidity sensor. The relative humidity measurement value (percentage) is shown in the field [7] on the display.

Temperature Units

The sound level meter is equipped with a temperature sensor. The temperature measurement value is shown in the field [16] on the display.
Use the °C/°F button to switch the temperature measurement unit between degrees Celsius (°C icon [15]) and degrees Fahrenheit (°F icon [17]).

A- and C-weighted Values

The sound level meter can measure both A- and C-weighted sound values. To switch between the weighting modes, press the °C/°F button for two seconds. Icons A [9] and C [10] on the display represent the currently chosen mode.

In the A-weighting mode, the meter captures the sound level in approximately the same way as the human ear does, cutting off the lower and higher frequencies. This mode is suitable for assessing the noise level of work environments and other public spaces to comply with the occupational health and safety requirements.

In the C-weighting mode, the meter captures the sound level with a much flatter frequency response. This mode is used to analyze the loudness of motors, machines, and other working equipment.

Low Battery Indication

When the battery voltage is low, the device shows the low battery icon [5]. It is recommended to replace the exhausted battery as soon as possible to avoid inaccurate readings.

To avoid damaging the device, do not open the battery compartment cover when the device is turned on.

Specifications

Sound pressure, range 30–130dBA / 30–130dBC
Sound pressure, accuracy 1 ±1.5dB (94dB at 1kHz)
Sound pressure, accuracy 2 ±5dB (94dB at 8kHz)
Sound pressure, frequency response 30Hz… 8kHz
Sound pressure, time weight FAST 125ms, SLOW 1s
Ambient temperature, range –20.0… +60.0°C (–4.0… 140.0°F)
Ambient temperature, accuracy 0.0… +45.0°C (32… 113°F): ±1.0°C/2.0°F

other: ±1.5°C/3.0°F
Ambient humidity, range| 0.0–99.9%
Ambient humidity, accuracy| 20–80%: ±5.0% RH
other: ±6.0% RH
Operating temperature range| 0… +50°C (+32… +122°F)
Storage temperature range| –10… +50°C (+14… +122°F)
Power supply| 3pcs AAA 1.5V alkaline batteries
Safety rating| EN61326-1

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care And Maintenance

Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions. Do not try to disassemble the device on your own for any reason. Do not use the device if it is damaged or does not operate properly. Replace the battery as soon as the low battery indicator lights up. Do not use solvent to clean the device. Store the device in the place with appropriate temperature (see “Specifications”). Protect the device from sudden impact and excessive mechanical force. Never attempt to operate a damaged device or a device with damaged electrical parts! Only use accessories and spare parts for this device that comply with the technical specifications. If a part of the device or battery is swallowed, seek medical attention immediately.

Battery Safety Instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Ermenrich Warranty

Ermenrich products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Ermenrich accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Ermenrich product in any country where a Levenhuk office is located if all the warranty conditions are met.
For further details, please visit: levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

CUSTOMER SUPPORT

Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102,
Czech Republic, +420 737-004-919, [email protected]
Levenhuk USA 928 E 124th Ave. Ste D, Tampa, FL 33612,
USA, +1 813 468-3001, [email protected]
Levenhuk®, Ermenrich® are registered trademarks of Levenhuk Optics s.r.o. (Europe).
© 2006–2024 Levenhuk, Inc. All rights reserved.
ermenrich.com
20240517
Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals