MEAN WELL NTS-2200 series High Reliable True Sine Wave DC AC Power Inverter User Guide
- June 8, 2024
- MEAN WELL
Table of Contents
- MEAN WELL NTS-2200 series High Reliable True Sine Wave DC AC Power
- Product Usage Instructions
- Frequently Asked Questions
- Features
- Applications
- Description
- Model Encoding
- SPECIFICATION
- AC Output Socket
- DERATING CURVE
- LED STATUS
- MECHANICAL SPECIFICATION
- Accessory List
- TYPICAL APPLICATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL NTS-2200 series High Reliable True Sine Wave DC AC Power
Inverter
Specifications
Model No.| Rated Power (Continuous)| Over Rated Power (3 Min.)| Peak Power (10
Sec.)| Surge Power (30 Cycles)| AC Voltage Output| Frequency| Waveform
---|---|---|---|---|---|---|---
NTS-2200-112 / NTS-2200-124| 2200W| 2530W| 3300W| 4400W| True sine wave| AC
Regulation
NTS-2200-148| 2200W| 2530W| 3300W| 4400W| True sine wave| AC Regulation
NTS-2200-212 / NTS-2200-224| 2200W| 2530W| 3300W| 4400W| True sine wave| AC
Regulation
NTS-2200-248| 2200W| 2530W| 3300W| 4400W| True sine wave| AC Regulation
Product Usage Instructions
Installation
Follow the installation guidelines provided in the user manual to properly set up the power inverter.
Connection to Power Source
Connect the DC input source to the power inverter according to the specified input requirements for your model.
Operating the Inverter
Switch on the power inverter using the designated power button. Monitor the output on the AC side to ensure proper functioning.
Safety Precautions
Always follow safety precautions while operating the power inverter to prevent any accidents or damage to the device.
Frequently Asked Questions
Q: Can I use the power inverter with a car battery?
A: Yes, you can use the power inverter with a car battery as long as the input voltage matches the specifications of the inverter.
Q: What should I do if the inverter overheats?
A: If the inverter overheats, immediately switch it off and allow it to cool down before attempting to use it again.
Q: Is the power inverter suitable for outdoor use?
A: The power inverter can be used outdoors, but ensure it is protected from moisture and extreme weather conditions.
2200W High Reliable True Sine Wave DC-AC Power Inverter
Features
- True sine wave output (THD <3%)
- High surge power up to 4400W
- Temperature controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- No load disspation <1.7W at standby saving mode
- -25°C~+70°C wide operating temperature
- Power ON-OFF remote control
- Front panel indicator for operation status
- Protections :
- Input : Reverse polarity / DC. low alarm / DC low shutdown / Over voltage
- Output : Short circuit / Overload / Over temp.
- Battery over discharge protection (low voltage disconnect)
- Suitable for lead-acid or li-ion batteries
- Remote controller (IRC1, IRC2, IRC3 accessory sold separately, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1 )
- Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold sperately)
- Carry handle accessory available(Order NO.: Carry handle, sold separately)
- Conformal coating
- 3 years warranty
Applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehicle
- Yacht
- Off-grid solar power system
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
NTS-2200 is a 2200W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 4400W peak power, adjustable AC output voltage and frequency, -25~+70°C wide operating temperature range, complete protection features, and etc. Combined with batteries, the NTS-2200 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Model Encoding
SPECIFICATION
MODEL NO.
| NTS-2200-112| NTS-2200-124| NTS-2200-148| NTS-2200-212|
NTS-2200-224| NTS-2200-248
---|---|---|---|---|---|---
= US, UN, TB| = EU, CN, AU, UK, UN, TB
AC OUTPUT
| RATED POWER(Continuous)| 2200W| 2200W
OVER RATED POWER(3 Min.)| 2530W| 2530W
PEAK POWER(10 Sec.)| 3300W| 3300W
SURGE POWER(30 Cycles)| 4400W| 4400W
AC VOLTAGE| Factory setting set at 110VAC| Factory setting set at 230VAC
100 / 110 / 115 / 120Vac selectable by DIP S.W| 200 / 220 / 230 / 240Vac
selectable by DIP S.W
FREQUENCY| Factory setting set at 60±0.1Hz| Factory setting set at
50±0.1Hz
50/60Hz selectable by DIP S.W| 50/60Hz selectable by DIP S.W
WAVEFORM **Note.1| True sine wave (THD<3%)
AC REGULATION| ±3.0% at rated output voltage
FRONT PANEL LED**| Please see page 5
DC INPUT
| DC VOLTAGE| 12Vdc| 24Vdc| 48Vdc| 12Vdc| 24Vdc| 48Vdc
VOLTAGE RANGE (Typ.)| 10 ~ 16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc| 10 ~
16.5Vdc| 20 ~ 33Vdc| 40 ~ 66Vdc
DC CURRENT (Typ.)| 250A| 120A| 60A| 250A| 120A| 60A
NO LOAD DISSIPATION (SAVING MODE)(Typ.) Note.2| Default disable,
auto detect AC output load≦10W will be changed to saving mode
1.7W
OFF MODE CURRENT DRAW| ≦2mA
EFFICIENCY (Typ.) Note.1| 89%| 90%| 91%| 90%| 92%| 93%
BATTERY TYPES| Lead Acid or li-ion
PROTECTION| DC INPUT| FUSE (INTERNAL)| 40A8| 40A4| 25A4|
40A8| 40A4| 25A4
LOW
| ALARM| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc| 11±0.3Vdc| 22±0.5Vdc| 44±1Vdc
SHUTDOWN| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc| 10±0.3Vdc| 20±0.5Vdc| 40±1Vdc
RESTART| 12.5±0.3Vdc| 25±0.5Vdc| 50±1Vdc| 12.5±0.3Vdc| 25±0.5Vdc|
50±1Vdc
HIGH
| ALARM| 15.5±0.3Vdc| 31±0.5Vdc| 62±1Vdc| 15.5±0.3Vdc| 31±0.5Vdc|
62±1Vdc
SHUTDOWN| 16.5±0.3Vdc| 33±0.5Vdc| 66±1Vdc| 16.5±0.3Vdc| 33±0.5Vdc|
66±1Vdc
RESTART| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc| 15±0.3Vdc| 30±0.5Vdc| 60±1Vdc
BAT. POLARITY| By internal fuse open
AC OUTPUT| OVER TEMPERATURE| Protection type : Shut down o/p
voltage, re-power on to recover
OUTPUT SHORT| Protection type : Shut down o/p voltage, re-power on to
recover
OVER LOAD (Typ.)| 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10
sec.
Protection type : Shut down o/p voltage, re-power on to recover
CIRCUIT BREAKER| 25A (Only for “TB” type)| None
TB TYPE| UL458 (Only for “TB” type AC socket)| None
FUNCTION
| REMOTE CONTROL| CONNECTOR| Power ON-OFF remote control by
front panel dry contact connector(by RELAY), Open : Normal work ; Short :
Remote off
ACCESSORY| Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
RS-232 COMMUNICATION| RS-232 ~ RJ11 Type connector (Please refer to page
4 for more details)
ENVIRONMENT
| WORKING TEMP.| -25 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY| 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-
condensing
VIBRATION| 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY
& EMC
(Note.5)
| SAFETY STANDARDS| CB IEC62368-1,Dekra Seal BS EN/EN62368-1,UL458, UL62368-1, E13,EAC TP TC 004,AS/NZS 62368.1 approved
(Please refer to next page“AC output socket” table for more details)
WITHSTAND VOLTAGE| DC I/P – AC O/P:3.0KVAC AC O/P – FG:1.5KVAC
EMC EMISSION
| Parameter| Standard| Test Level / Note
Radiated| FCC for 112,124,148 only(expect for Type-UN)| Class A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)| Class A
Harmonic Current| BS EN/EN61000-3-2| —–
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN55035
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2, 3V/m
Magnetic Field| BS EN/EN61000-4-8| Level 1, 1A/m
OTHERS
| MTBF| 364.7K hrs min. Telcordia TR/SR-332 (Bellcore) ; 34.9K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 42027098mm (LWH)
PACKING| 8.6Kg; 1pcs/ 10.4Kg/ 1.39CUFT
NOTE
|
- Efficiency, AC regulation and THD are tested by 1650W load, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
- No load dispation at non-saving mode(Typ.): 112/124/148 for 25W, 212/224/248 for 55W.
- All parameters not specified above are measured at rated load, 25 C of ambient temperature and set to factory setting.
- Internal pre-start circuit, the setup time is 8s.
- The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI
_statement_en.pdf)
- Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
AC Output Socket
DERATING CURVE
IRC1/2/3 Remote Controller (Accessory sold seperately)
-
IRC1/IRC2/IRC3 is the monitoring and control unit.
-
IRC1/IRC2/IRC3 can decode the RS-232 signals sent by the inverter series and display through digital meters.
Note: Part of the control signals will not function properly due to different compliance of each model. -
Please refer to for more detail: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1
Support RS-232 Communication
The internal data of single NTS-2200 can read through RS-232.
- Please refer to for more detail: http://www.meanwell.com/manual.html
- RJ11-RS232 Communication cable should be ordered seperately, Order No.: RJ11-RS232
Remote ON-OFF Control (Built-in)
Remote ON-OFF | AC Output Status |
---|---|
Open | power inverter ON |
Short | power inverter OFF |
AC Output Voltage. Frequency, Power saving mode selectable by DIP SW
Output voltage and frequency setting factory settings are either
110Vac/60Hz or 230Vac/50Hz, users are able to adjust the voltage and
frequency, through the DIP switch of position 1,2,3,4 on the panel.
AC Output Voltage、 Frequency、Power saving mode selectable by DIP SW
SW1| SW2| SW3| SW4
OFF| OFF :| 100Vac or 200Vac|
ON : 50Hz
|
ON : Saving mode
OFF| ON :| 110Vac or 220Vac
ON| OFF :| 115Vac or 230Vac|
OFF: 60Hz
| OFF: Non-Saving mode
ON| ON :| 120Vac or 240Vac
LED STATUS
Normal work:
Abnormal status :
MECHANICAL SPECIFICATION
Accessory List
Communication cable (Optional accessory, Power inverter and Communication cable should ordered seperately)
Carryl handle (Optional accessory, Power inverter and Pull handle should ordered seperately)
Terminal protector mating along with NTS-2200 (Standard accessory)
TYPICAL APPLICATION
Please refer to : http://www.meanwell.com/manual.html
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>