Commercial Electric Led Direct Wire Under Cabinet Light User Guide

June 7, 2024
Commercial Electric

Commercial Electric Led Direct Wire Under Cabinet Light -
logo
SKU# 1001 217466 (9 in.)/1001 192 583 (12 in.)
1001 217 444(18 in.)/1001 217 457(24 in.)
UPC# 847658001603 (9 in.)/847658001610 (12 in.)
847658001627 (18 in.)/847658001634 (24 in.)
USE AND CARE GUIDE
LED DIRECT WIRE UNDER-CABINET LIGHT (WHITE FINISH)

Commercial Electric Led Direct Wire Under Cabinet Light - cabinet
light

Questions, problems, missing parts?
Before returning to the store, call Commercial Electric Customer Service
8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m. Saturday
1-877-527-0313
HOMEDEPOT.COM
THANK YOU
We appreciate the bust and confidence you have placed in Commercial Electric through the purchase of this under cabinet light. We shire to continually create quality products designed to enhance your home* visit us Wine to see our full line of products available for yew home improvement needs. Thank you for choosing Commercial Electric!

Safety Information

Carefully read and understand the information in this manual before you begin installation. Failure to do so could lead to electric shock or a fatal hazard.
WARNING : Changes or modifications not expressly Aapproved by the party responsible for compliance could void the user’s authority to operate the equipment.
WARNING : This product must be installed in accordance A1with the applicable installation code by a person familiar : with the construction and operation of the product and the hazards involved.
WARNING : This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules and ICES-005 of the IC Rules. These limits are designed to provide reasonable installation protection. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does Acause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
❑ Reorient or relocate the receiving area.
❑ Increase the separation between the equipment and the receiver.
❑ Connect the equipment into a different outlet and circuit from the receiver outlet and circuit. o Consult the dealer or an experienced radio/TV techni- cian for help.

Supplier’s Declaration of Conformity
47 CFR § 2.1077 Compliance
Information Unique Identifier: 57001A-WH , 57002A-WH 57003A-WH , 57004A-WH Responsible Party: Buckingham 7390 McGinnis Ferry Road Suite 200 Suwanee, GA 30024 Tel: 678-765-2995

SPECIFICATIONS

❑ The 9 in. fixture with SKU# 1001 217466 is rated at 120V/60HZ 6W 55mA.
❑ The 12 in. fixture with SKU# 1001 192 583 is rated at 120V/60HZ 9W 85mA.
❑ The 18 in. fixture with SKU# 1001 217 444 is rated at 120V/60HZ 15W 150mA.
❑ The 24 in. fixture with SKU# 1001 217 457 is rated at 120V/60HZ 17W 175mA.

CAUTION : This is a non-replaceable LED light source. ADo not dismantle this fixture. There are no user serviceable parts inside.
CAUTION : For indoor and dry location use only.
CAUTION : Do not touch the fixture when the light source is ON.
CAUTION : Ensure the electricity is shut off before you Ainstall or work on this light. Either remove the fuse or turn off the circuit breaker.
CAUTION : Deviation from the assembly instruction may result in a risk of fire and electric shock.
CAUTION : Do not operate this fixture with a missing or damaged cover or housing.
CAUTION : Do not mount this fixture near a heat source as it may damage this fixture.
CAUTION : Do not stare directly into the LED light.

Limited Warranty

The manufacturer warrants this product to be free from defects in materials and workmanship for a period of five (5) years from date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal use and service. If this product is found to be defective, the manufacturer’s only obligation, and your exclusive remedy, is the repair or replacement of the product at the manufacturer’s discretion, provided that the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect or mishandling. This warranty shall not apply to any product that is found to have been improperly installed, set-up, or used in any way not in accordance with the instructions supplied with the product. This warranty shall not apply to a failure of the product as a result of an accident, misuse, abuse, negligence, alteration, or faulty installation, or any other failure not relating to faulty material workmanship. The manufacturer specifically disclaims any liability and shall not be liable for any consequential or incidental loss or damage, including labor/expense costs involved in the replacement or repair of said product. Contact the Customer Service Team at 1-877-527-0313 or visit www.HomeDepot.com.

Pre-Installation

PLANNING INSTALLATION
Compare all parts with the parts listed in the Hardware Included and Package Contents sections. If any part appears missing or damaged, do not install and use this light. Contact customer service.
TOOLS REQUIRED

Commercial Electric Led Direct Wire Under Cabinet Light -
tools

HARDWARE INCLUDED
Note : Hardware not shown to actual size.

Commercial Electric Led Direct Wire Under Cabinet Light - tools
2

Part Description Quantity
AA Screw (Die-cast connector) 2
BB Clamp (Die-cast connector) 1
CC Mounting sleeve (Die-cast connector) 1
DD Hex nut (Die-cast connector) 1
EE Fixture mounting screw 3
FF Wire connector 3
GG Screw (preassembled on fixture) 2

PACKAGE CONTENTS

Commercial Electric Led Direct Wire Under Cabinet Light -
packing

Part

| Description|

Quantity

---|---|---
A| Light fixture| 1

Installation

1 Preparing the light for installation
❑ Remove two screws (GG) on the back of the fixture for access to the wiring compartment.
IMPORTANT : Keep the screws (GG). You need them to install the back plate to the fixture. There are no additional screws (GG) in the package.
Commercial Electric Led Direct Wire Under Cabinet Light -
instalation
❑ Determine the electrical feed location.
❑  Remove a knockout from either the back plate or side of the fixture housing. The fixture has 2 to 6 knockouts depending on length of your fixture. This drawing shows the 18 in. model and is for reference only.

Commercial Electric Led Direct Wire Under Cabinet Light - instalation
2

3 Connecting the wires
❑  Install the Die-cast connector and lock it in the knockout (see Figure 1).
❑ Connect the ground wire from the fixture to the ground wire from the supply circuit- Canned the white wire from the Futon to the white wire (Neutral wire) from The supply circuit. Connect the black wire from the fixture to the black wire give wire) from the supply wait Cover the three connections using the three wire connectors (FP). Position the wires back Inside the outlet box. Make sure the wire connections are secured.
NOTE: Betore you connect tans make sure to ONOFF smith on the palace Is OFF or It may cause potential risk if the switch is ON.
Commercial Electric Led Direct Wire Under Cabinet Light - fig
1
4 Re-attaching the back cover
❑  Re-attach the back cover of the wiring compartment with the two previously- removed screws (GG).
NOTE: Ensure the wires are covered properly inside the fixture.

Commercial Electric Led Direct Wire Under Cabinet Light - back
cover
5 Mounting the light fixture
NOTE: The fixture mounting screws are suitable for cabinet bottoms 3/8 in. or thicker. Use shorter screws for thinner cabinet bottoms.
❑ Attach the light to the desired surface,mark the screw location.
❑ Pre-drill holes in the mounting surface with a 1/16 in (1.5mm) drill bit to make installing screws easier.
❑ Use the fixture mounting screws (EE) to attach the light to the marked location.
❑ Restore power to the electrical circuit at the service panel.
❑ Turn on the switch to light the fixture.

Commercial Electric Led Direct Wire Under Cabinet Light -
mounting

NOTE : These fixtures are dimmable and compatible with these dimmers sold at The Home Depot.
❑ Make sure the lights are in a single loop and a single pole with the dimmers, and that the total wattage of the lights does not exceed the dimmer wattage capacity. Please refer to wattage capacity on the dimmer packaging.
❑ Please contact customer service if you have any further questions on the lights or dimmers. (Model#/SKU#): Lutron brand: DVWCL-153PH-WH / 530826; CTCL- 153PDH-WH / 267858; TGCL-153PH-WH / 527401; S-600PR-WH / 396682; TG-600PR-WH / 400017; P-PKG1W-WH-R / 1000027680; DVCL-153PR-WH /396508; MACL-153MH-WH / 739664 Leviton brand: R62-06683-0IW / 534006; R12-06672-1 LW / 1000024040; R62-06674-POW/125569; R50-1PL06-10M/976708

Luminous Intensity Distribution

Commercial Electric Led Direct Wire Under Cabinet Light -
distribution

Commercial Electric Led Direct Wire Under Cabinet Light -
logo

Questions, problems, missing parts?
Before returning to the store, call Commercial Electric Customer Service
8 a.m. – 7 p.m., EST, Monday – Friday, 9 a.m. – 6 p.m. Saturday
1-877-527-0313 H OM ED EPOT.00 M Retain this manual for future use.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Commercial Electric User Manuals

Related Manuals