WARNINGS
Because the product must be connected to a 230 VAC power supply and to a
heating appliance, installation should only be carried out by qualified
personnel to avoid irreparable damage to the product and / or the heaters that
are connected , defects not covered by warranty.
We recommend that you have qualified personnel with experience in this field,
for initial setup of the equipment in order to understand correctly the
technical terms and procedures detailed in this manual.
After installation and connecting, the product is easy to use both mobile unit
and smartphone controll with an intuitive and easy to configure interface.
To access / monitor / control the product remotely from your smartphone, it is
necessary to have an internet source (WiFi router) close to where thermostat
is installed.
GENERAL INFORMATION
The smart thermostat PNI CT35 has been developed to provide customers extra day-to-day comfort in their homes, in the office or other premises, offering the ability to monitor and turn on or off heating systems either automatically scheduled for every day of week, either remotely, anytime and anywhere via the Internet with dedicated app for Android or iOS Smartphone.
Mode of operation and communication:
Dedicated app name is TuyaSmart and can be downloaded either from the
Googel Play / App Store, either by scanning with your smartphone the QR code
below:
Package content:
- Main unit with illuminated screen
- Receiver / relay command unit
- Wall / table mount accessories
- User manual
TECHNICAL DETAILS / SPECIFICATIONS
- Main unit power supply: 2 AAA batteries
- Receiver power supply: 230VAC 50 / 60Hz
- Receiver unit command type: NO Relay (normally open) 10 Amps max
- Set point range temperature: 5 – 35o C
- Measurable ambient temperature: 0 – 50o C
- Temperature measurement unit: only o Celsius degrees
- Acceptable humidity: 85% no condensation
- Screen illumination: white light
- Temperature sensor: NTC 10K, 3950ohms at 25o C
- Sensor accuracy: ± 0.5 °C (adjustable by 0.5 °C step sensor calibration)
- Protection degree: IP30
- Housing: ABS with UL94-5 fire retardant plastic standard
- WiFi connectivity: 802.11 b / g / n (2.4 GHz); WPA2 (TKIP and AES)
- RF frequency connectivity between units: 868 MHz
- Smartphone Compatibility: Minimum iOS 9 / minimum Android 4.2
MAIN UNIT DESCRIPTION
RECEIVER DESCRIPTION
FIRST USE WARNINGS AND INSTRUCTIONS
- The system comes with main unit and receiver paired from factory. Before use, you only need to pair the receiver unit with the nearby Wireless Router.
- At first start, the thermostat / receiver unit signals by LED 1 = “ slow blinks” that means it is necessary to connect unit to the wireless router with Internet access.
- Insert 2 AAA alkaline batteries (not included) into the main unit and turn it on by pressing the ON / OFF button. The settings appear as shown in above description.
- Connect the receiver unit to a 230 VAC power supply (only qualified personnel). Make sure it works properly by testing / checking the LED status and turning unit On/Off by dedicated button.
PAIRING THERMOSTAT WITH MOBILE APP AND WIRELESS INTERNET ROUTER
- Connect your smartphone to wireless Internet router nearby. For a quick setup make sure both phone, thermostat receiver and wireless router are as close as possible (1-3 m).
- Download “TuyaSmart” app from Google Play or App Store, andd install and register a new account.
- Add device by pressing the + button in the top right corner.
- Press “All Devices”.
- Find “Heater” or “Thermostat” from list and select.
- Long press the pairing button on the receiver to enter Wifi pairing mode until LED 1 blinks quickly. (before this, LED 1 blinks slow, sign that thermostat is not paired with wifi internet router)
- Tap the “Confirm indicator flash blink” on your phone.
- Wait a few moments until pairing is complete. The LED 1 on the receiver will stop blinking and turn off. At this point, connection to the Internet via Wirelessrouter is successful, and the Thermostat icon will appear in Smartphone app.
If the LED continues to blink slowly, the connection failed, try again from step 5.
FIRST USAGE OF THERMOSTAT
- With main unit screen ON, change the temperature bigger or smaller then measured temperature from screen.
- In a maximum 90 seconds, the main unit sends a command to receiver unit, which confirms by turning on / off LED 1, and by a “click”, that is heard from inside relay.
- From TuyaSmart app (make sure the device appears online after configuring internet pairing ) tap on the device to access it. Using the “+” and “-” buttons, change the temperature bigger or smaller then measured temperature from screen.
- In 90 seconds or more, the application sends command through internet to thermostat receiver unit, which confirms by turning on / off LED 1, and with a “click” sound from inside relay. The temperature will change on the main unit screen.
If there is no change after 90 – 180 seconds (2 minutes), check again if you have changed the temperature to bigger / smaller than current temperature displayed and check if the device is online.
PAIR MAIN UNIT WITH RECEIVER UNIT
Perform this procedure only if it is absolutely necessary: if you have problems controlling main unit settings from smartphone app, after pairing receiver with wireless router ( the screen does not receive commands for 5 – 10 minutes from mobile app).
- Press and hold the pairing button on receiver until LED 1 flashes quickly.
- With main unit screen closed (press the On / Off button), long press the M button on the main unit until a 4-digit code and three more symbols appear on screen. Press the “up arrow” button immediately for pairing.
- LED 1 blinks slowly; wait for a few moments until LED 1 stops flashing and closes. The pairing is completed.
- Switch off and on the main unit, and test functions by changing temperature higher / lower than the actual temperature from thermostat screen.
DELETE CLEAR ALL PAIRING
On receiver unit press and hold both pairing and On/Off buttons for 5 seconds
until LED1 and LED2 turn on. Release buttons.
Then LED 1 turns off, which means that all pairing have been cleared.
SIGNAL LOST OR WEAK
- In case the RF and WIFI signal lost/disconnected, LED 2 will flicker slowly.
- Move units closer to each other and the WiFi router and check the status of the devices again.
- If within a few minutes the operation does not return to normal, delete all pairing and perform the pairing procedures of receiver, main unit, and the wireless router (with the mobile application) again.
HOUR/DATE SETTING
- With main unit screen On, press and hold the M button for 5-6 seconds until the hour on the screen blinks.
- You will see highlighted 00:00 on the screen. Set the minutes with the up and down buttons.
- Continue pressing the M button.
- Set the time with the up and down buttons.
- Continue pressing the M button.
- Select the day with the up and down buttons.
- Continue pressing the M button.
- Save the settings by pressing the ON / OFF button or wait about 15 seconds.
OPEN WINDOW DETECTION FUNCTION
When the “open window” detection mode is activated in advanced settings, the system will automatically switch off heating if a sudden decrease in temperature (2°C in 15 minutes by default) occurs. This function is useful when opening a door / window (eg ventilation) without stopping the heating. The thermostat will return to previous working mode after 30 minutes, and the “OP” icon will disappear from the screen. Press any button and thermostat will exit OWD function, during the heating off period.
OTHER FEATURES AVAILABLE IN YOUR SMARTPHONE APPLICATION
In TuyaSmart app you have the following features available:
- Measured temperature and programmed / set temperature by user;
- Heating Status: The “Heating” text appears on screen when the heat is on;
- 3 working modes: manual, Eco (economical) and automatic (according to daily schedule)
- Child lock function- Thermostat keyboard lock to stop accidental push of buttons
- Daily schedule (7 days) with 4 hour zones every day;
- Scheduled temperature timing
SET UP DAILY PROGRAMS
This setup n can also be done from smartphone app, wich we recommend.
With the on-screen display, press and hold the P button (6-7 seconds) to enter
the PROGRAM settings. Days of the week are fixed from Monday to Sunday (1 ~
7), each day has 4 time periods (1 ~ 4). Each press of the P button can be
performed in the next setting.
- Press P and hold for 3 seconds, the “hour” display flashes, change the value with the + and – buttons.
- Press the P button, the temperature blinks, change the desired temperature with the + and – buttons.
- Press the P button for the next time.
- Repeat the settings for the other days and periods similarly.
Period
|
1
|
2
|
3
|
4
---|---|---|---|---
–
| Hour| Temp| Hour| Temp| Hour| Temp| Hour|
Temp
12345 (Mon-Fri)| 7:00| 22 o C| 8:30| 19 o
C| 17:00| 22 o C| 22:00| 19 o C
6 (Sat.)| 8:00| 22 o C| 8:30| 22 o C|
17:00| 22 o C| 22:00| 19 o C
7 (Sun.)| 8:00| 22 o C| 8:30| 22 o C|
17:00| 22 o C| 22:00| 19 o C
ADVANCED PARAMETER SETTINGS
urn the thermostat screen Off by pressing the On / Off button. With screen Off, press and hold in the same time and button for parameters settings.
MENU
|
Description
|
Range
|
Defalt value
---|---|---|---
01
|
Temp. calibration for internal sensor
|
-8 o C ~ 8 o C
|
0 o C
02
|
Set Point Max.
|
5 o C ~ 35 o C
|
35 o C
03
|
Set Point Min.
|
5 o C ~ 35 o C
|
35 o C
05
|
Frost Protection Temp.
|
5 o C ~ 15 o C
|
5 o C
09
|
Histerezis ( Deadzone)
|
0 o C ~ 3 o C
|
0 o C
12
|
Open window detect function-OWD
|
1: ON 0: Off
|
0
13
|
OWD – Detect time
|
2 ~ 30 minutes
|
15 minutes
14
|
OWD – Drop temp. select ( within detect time)
|
2,3,4 o C
|
2 o C
15
|
OWD – Delay time select (Return to previous working status)
|
10 ~ 60 minutes
|
30 minutes
17
|
Factory reset
|
0 : No
|
0
1: Yes, and then press On/off button for 5s,wait until thermostat restart.
–
|
Software Version
|
5055-02
| –
RECEIVER WIRING DIAGRAM
The operation of connecting the receiver unit with 230 V power supply and
central heating system must be performed only by qualified personnel and only
after consulting the thermostat and boiler documentation.
The receiver unit has a NO/NC relay (Normal Open and Normal Clos) that support
closing of a circuit with a maximum current of 10 A.
INSTALLATION AND DIMENSIONS
The main and receiver unit can be mounted in 2 ways:
-
Table or flat surface area with the white holder inside package:
-
On the wall with wall holder:
EU Simplified Declaration of Conformity
SC ONLINESHOP SRL declares that Smart thermostat PNI CT35 complies with
the Directive EMC 2014/30/EU and RED 2014/53/UE and LVD
2014/35/EU. The full text of the EU declaration of conformity is available at
the following Internet address:
https://www.mypni.eu/products/6434/download/certifications