Installation:

  1. Follow steps 6-8 from the Installation and Operation Manual:
    IW25-5 Dehumidifier IN Wall (page 9).

  2. Once step 8 is complete, there will be a cut out opening to
    partially recess the IW25-5 into the cavity wall. Fit the exterior
    sleeve against the cut-out opening. Make sure the pop-out for
    drain/power are at the bottom of the sleeve.

  3. Ensure the Exterior Sleeve is level and bottom of the IW25-5
    will be supported. Attach Exterior Sleeve with 4 screws (not
    provided) directly through the wall into studs.

  4. Continue to Step 9 of the In Wall installation
    instructions.

  5. In Step 11 of the In Wall installation instructions, use the
    four screws (included with the Exterior Sleeve) to attach the
    mounting tabs to the Exterior Sleeve.

  6. Continue installation instructions in the manual from step 12
    to finish installation.

Frequently Asked Questions (FAQ)

Q: Is the Exterior Sleeve covered under the IW25-5 Dehumidifier

Warranty?

A: No, the Exterior Sleeve is not covered under the IW25-5
Dehumidifier Warranty.

Q: Is the Exterior Sleeve compatible with the IW25-5 ON Wall

Dehumidifier?

A: No, the Exterior Sleeve is not compatible with the IW25-5 ON
Wall Dehumidifier.

“`

Installation Manual
IW25-5 IN Wall Dehumidifier Exterior Sleeve

Please Read and Save These Instructions

Contact Us:
IXL Home Pty Ltd 1K Marine Parade, Abbotsford, VIC 3067

AUS: 1300 727 421 NZ: 0800 727 421

www.ixlappliances.com.au www.ixlappliances.co.nz

IW25-5 IN Wall Dehumidifier Exterior Sleeve Installation

The IW25-5 In Wall Dehumidifier can be semi-recessed with an Exterior Sleeve for a clean bump out finish, where unit cannot be fully installed into a 90mm stud wall, ideal for retrofit applications.

The Exterior sleeve is not covered under the IW25-5 Dehumidifier Warranty and is not compatible with the IW25-5 ON Wall Dehumidifier.
Exterior Sleeve Dimensions: 445mm W x 775mm H x 56mm D

Exterior sleeve mounted against wall and firmly secured into a solid surface. (ie timber stud)

IW25-5 In Wall unit with mounting brackets attached to Exterior Sleeve

IW25-5 In Wall Dehumidifier installed with Exterior Sleeve and cover.

368mm
19mm
Figure 1

711mm 19mm

Installation
1. Follow steps 6-8 from the Installation and Operation Manual: IW25-5 Dehumidifier IN Wall (page 9).
2. Once step 8 is complete, there will be a cut out opening to partially recess the IW25-5 into cavity wall. Fit the exterior sleeve against the cut- out opening. Make sure the pop-out for drain/power are at the bottom of sleeve.(Figure 1)
3. Ensure the Exterior Sleeve is level and bottom of the IW25-5 will be supported. Attach Exterior Sleeve with 4 screws (not provided) directly through wall into studs.
4. Continue to Step 9 of the In Wall installation instructions.
5. In Step 11 of the In Wall installation instructions, use the four screws (included with the Exterior Sleeve) to attach the mounting tabs to the Exterior Sleeve.
6. Continue installation instructions in manual from step 12 to finish installation.