Wohler 22714 Fog Spray Gun with Fluid User Manual
- June 4, 2024
- WOHLER
Table of Contents
Operating manualFog Spray Gun with Fluid
General Information
1.1 Operation ManualInformation
This operation manual allows you to safely work with the Fog Spray Gun. Please
keep this manual for your information. The Fog Spray Gun should be used by
professionals
for its intended use only. Liability is void for any damages caused by not
following this manual.
1.2 Notes
WARNING!
Not following this warning can cause injury.
ATTENTION!
Not following this note can cause permanent damage to the device.
NOTE!
Useful information
1.3 Intended Use
The Fog Spray Gun produces small fog clouds for the visualization of air streams and leakage detection in the building shell.
1.4 Components
Device | Components |
---|---|
Fog Spray Gun | Fog Spray Gun |
Fan Body with Cone, only full set
6 standard batteries 1,5 V, LR6 alkaline (full set: 7 batteries)
Fluid, 85 ml
1.5 Information on disposal
Electronic equipment does not belong to domestic waste, but must be disposed of in accordance with the applicable statutory provisions. You may hand in any defective batteries taken out of the unit to our company as well as to recycling places of public disposal systems or to selling points for new batteries or storage batteries.
1.6 Direction
Wöhler Technik GmbH
Wöhler-Platz 1
33181 Bad Wünnenberg
Tel.: +49 2953 73-100
Fax: +49 2953 73-250
Safety information
2.1 Operation of theFog Spray Gun
WARNING!
This is a battery-powered device. Do not use in volatile combustible
environments.
2.2 Fluid
The fluid contains glycerin and distilled water. The fluid is not inflammable and not dangerous. Nevertheless, the following rules should be observed.
WARNING!
– The fluid can cause eye irritations. In this case, the conjunctiva will
be reddened. In this case, flush eyes with plenty of water.
– In rare cases, the fog can provoke asthmatic reactions.
– Do not eat and drink the fluid.
Component explanation
- Cone (The unit can be used with or without Cone)
- Chimney
- Vapor Lever
- Power Button
- Fluid Level Window
- Fill Tank
- Empty Port
- green LED Power Light
- Air intake
- Battery compartment
Getting started
4.1 Installing the batteries
- Open the battery case with a screwdriver. The battery case is at the bottom side of the Fog Spray Gun.
- Install 6 standard batteries LR6, 1.5 V, alcaline.
ATTENTION!
Do not mix old and new batteries and always charge 6 batteries at the same
time.
- Always put two batteries in one case, one on top of the other.
ATTENTION!
Make sure the polarity is correct. The correct polarity is shown in the
battery lid.
- Close the battery lid and tighten the crosshead screws.
NOTE!
Instead of the cells, rechargeable batteries can be used.
4.2 Filling the tank with fluid
-
Remove the red tap (2) from the fluid bottle and remove the strap from the bottle
-
Remove the sealing ring (1) from the tap (2).
-
Put the sealing ring (1) on the bottle opening put the sprout (3) on the sealing ring and assemble it on the bottle with the tap (2).
-
Remove the cap (4) from the proud.
-
Before filling, lay the Fog Spray Gun on its side.
-
Insert the long sprout far into the tank (opening “Fill”) and fill the tank with fluid.
-
Control the fluid level in the tank at the Fluid Level Window. (under the Filling opening, see fig. 1, part 6). For this purpose, replace the Fog Spray Gun in an upright position. Fill the tank to 3/4 full.
NOTE!
Hold the Fluid Level Window to a light source to easily see the level of the
fluid.
4.3 Suction of the excess fluid from the overflow tank
The fog spray gun has a second tank for excess fluid. The fluid can be sucked from this tank in the following way.
- Squeeze the Fluid bottle.
- Insert the long nozzle into the “Empty” tank and release the pressure on the bottle so that the excess fluid in the tank is sucked back into the bottle.
Operation
5.1 Creating the fog
WARNING!
Operation in an environment with inflammable gas or vapor is not permitted.
ATTENTION!
Do not cover the air intake (fig. 1, part 8) during the operation.
-
Turn the Power –Button to the horizontal unlocked position.
-
Press the Power Button gently until the LED power light glows, indicating that power is on.
NOTE!
Hold for 6 to 9 seconds. This gives the coil in the vapor generator time to heat up. -
Then squeeze the Vapor Lever to deliver Fog Fluid to the Generator.
-
To produce a longer duration vapor stream, squeeze the power button/Vapor Lever just enough to see a thick vapor from the top of the chimney.
-
Then simply pulse the Vapor Lever by easing up on the lever, so the power light stays on, then increasing pressure on the lever to produce a controlled volume of vapor.
Repeat this pulsing action as long as vapor is needed.
5.2 Fan Body and one (only full set)
Use the Cone to create a narrow fog stream that makes the air stream clearly
visible (see fig. 1, part 2).
NOTE!
Cut the Cone Tube with a utility knife for a larger opening (0.5 to 1 cm).
ATTENTION!
Make sure the polarity is correct. The correct polarity is shown in the
battery case. To see the polarity symbols better, open the battery case and
put the Fan Body on a dark background.
-
Place the Fan Body on the Vapor Chimney of the Fog Spray Gun..
-
Turn on the Fan with the ON/OFF key of the Fan Body (part 1).
-
Turn the wheel (part 2), until the fog has the desired intensity.
NOTE!
If the wheel position is “LOW”, the fan will not start, when it is switched on. In this case turn the wheel to the position “High”, until the fan works. After that you can reduce it again. -
Create the fog as described in chapter 5.1.
Storage and transport
ATTENTION!
Improper transport or storage can harm the Fog Spray Gun. Other objects may
become soiled by the fog or fluid.
- To lock the Power Button, when storing or not in use, simply turn the Power Button so the key is vertical.
- Empty the fluid tank by sucking the fluid back into the bottle (see chapter4.3).
Failures
Failure | Possible reason | Solution |
---|
There is no power indicator
light or vapor| Disposable or rechargeable batteries are empty.| Replace the
batteries or, if using rechargeables, recharge
the batteries.
The batteries are not installed correctly.| Make sure that all batteries are
in the correct polarity position.
The power light shines but
very little or no vapor is
being produced.| The fluid tank is empty.| Fill the tank to 3/4 full.
The tank plug is not tight, so that there is no pressure in
the tank.| Make sure that the plug is
making a good seal.
The fluid tank is overfilled so that excess fluid is cooling
the Vapor Generator.| Suck out excess fluid with the Fluid Bottle (see chapter
4.3).
The Power/Vapor Lever is being depressed without allowing for the Vapor
Generator to heat up.| Hold the Power/Vapor Lever gently depressed for 6 – 9
seconds, then press more firmly.
Fluid is getting out of the
Fog Spray Gun| The tank is overfilled. Excess fluid is running out of
the Air Intake vents of the chimney.| Suck out excess fluid with the Fluid
Bottle (see chapter 4.3).
The tank plug is not tight| Press the plug down firmly to seal.
The unit is not transported or stored in an upright position.| Suck out the
fluid with the Fluid Bottle (see chapter 4.3).
Due to the oily nature of the Fog Fluid, when vaporized,
the fog easily condenses on the plastic surfaces of the
Fog Spray Gun and there will be some unavoidable residue of fluid.| Clean the
Fog Spray Gun with a paper tissue.
Warranty and Service
8.1 Warranty
Each Fog Spray Gun will be tested in all functions and will leave our factory only after extensive quality control testing. If used properly, the warranty period for the Fog Spray Gun will be twelve months from the date of sale. The Fluid is not covered by this warranty. This warranty does not cover the freight and packing costs when the device is sent to the factory for repair. Service by nonauthorized personnel or making modifications to the analyzer voids any warranty.
8.2 Service
Wöhler has built our reputation on excellence in customer service. Therefore, of course, we are readily available to assist you after the warranty period ends.
- Send us the device and we will repair it and return it to you with our package service.
- Immediate help is provided by our technical staff over the telephone.
Declaration of conformity
The product
name: Fog Spray Gun
complies with the key safety requirements set down in the guidelines of the
Council for the Harmonization of the Legal Requirements of the Member States
in relation to the
electromagnetic compatibility (2014/30/EU). The following standards were
availed of to evaluate the product in respect of electromagnetic
compatibility:
EN 55014-1:2006+A1:2009
EN 55014-2:1997 + A1:2001 + A2:2008
Certificate n° 2023213/EE
Bad Wünnenberg, 09.08.2022
Dr. Stephan Ester, Geschäftsführer/Managing Director
Points of sale and service
Your contact:
Germany
Wöhler Technik GmbH
Wöhler-Platz 1
33181 Bad Wünnenberg
Tel.: +49 2953 73-100
Fax: +49 2953 73-96100
info@woehler.de
www.woehler.de| USA
Wohler USA Inc.
208 S Main Street
Middleton, MA 01949
Tel.: +1 978 750 9876
www.wohlerusa.com
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>