Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in
personal injury or death from the improper use or the chemical solution.
Anyone handling, operating or using the unit must read and understand the
instructions in the manual. The buyer assumes all responsibility for safety
and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment
(PPE) may result in serious injury such as burns, rashes, eye, throat or lung
damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS)
when using or servicing the unit. Protect eyes, skin, and lungs against
drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical
solution and cause serious injury such as burns, rashes, eye damage, throat or
lung damage and death.
Always depressurize and clean the unit after each use. Never leave the unit
unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in
scalding, burns, serious injury or death. DO NOT use a solution with a
temperature above 100°F (37.8°C).
Some components may be hot during and after use. Use caution when servicing or
handling the equipment.
Operating the unit when damaged or leaking may result in exposure to chemical
solutions, serious injury or death. Never use the unit if it is damaged or
leaking.
Use of hydrocarbons and flammable products may result in explosions, fire and
serious injury or death. Never use hydrocarbons or flammable products with the
unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating
of the mixture may cause it to splatter caustic compounds or release hazardous
fumes, gas and vapors. Always flush the unit with fresh water thoroughly when
switching from an alkaline to an acid or an acid to
an alkaline.
Never point the discharge wand at yourself, another person, or any object you
do not want covered in chemical.
Keep battery box lid closed and latched at all times unless accessing battery.
Do not use with lid open or damaged. Do not expose unit to liquids, cleaning
solutions, or rain. The battery pack is not waterproof. Do not submerge in
liquid. If battery pack gets wet, allow to dry before further use.
Using the unit with unapproved devices may result in a risk of fire, shock or
personal injury. Only use with 24V Equip Series compatible equipment.
When not in use, store unit indoors in a cool, dry location. Keep unit away
from unauthorized users. To prevent premature battery failure, do not store
battery in a depleted state for long periods of time
WARNING
First Aid Instructions
- Failure to follow first aid instructions may result in death or serious personal
- If battery liquid comes in contact with skin, wash immediately with soap and water, then neutralize with lemon juice or
- If battery liquid gets in your eyes, flush with clean water for a minimum of 10 minutes, then seek immediate medical
- If battery liquid is swallowed, seek immediate medical
State of California Proposition 65 Warning
- The battery can expose you to chemicals, including cobalt, lithium, manganese, nickel, oxide, and carbon black, which are known to the State of California to cause cancer and reproductive harm. For additional information, go to P65Warnings.ca.gov.
NOTICE
Refer to the separate manuals supplied with the battery and charger for
additional safety precautions and instructions.
Servicing or modifying this unit with parts not listed in this manual may
cause the unit to operate improperly. Do not use unauthorized parts when
servicing the unit.
Protect the Environment
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations
Requirements
Liquid temperature range | 40-100˚F (4.4-37.8˚C) |
---|---|
Electrical requirements | 120-240 VAC at 50-60 Hz, 3A (GFCI protected outlet) |
for battery charger only
Operating voltage| 24 VDC
Chemical compatibility
| Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.
Specifications
Power type | Lithium-ion battery |
---|---|
Battery charge time | 1 hour 10 minutes |
Battery run time | Up to 4 hours of continuous use |
Chemical pickup type | Draws from pre-mixed solution |
Number of products unit can draw from | One product |
Suction line diameter | ⅜ in. (9.5 mm) inside diameter |
Capacity | 5 gallons (18.9 liters) |
Discharge line length/diameter | 12 ft. (3.7 m) hose, with 3/8 in. (9.5 mm) |
inside diameter
Discharge wand/tip type| Polypropylene spray gun with 25° fan tip
Output distance| Up to 8 ft. (2.4 m)
Output volume| 0.7 gal/min (2.7 l/min)
Flow rate*| 0.7 gal/min (2.7 l/min)
Pump seals| Santoprene diaphragm, Viton check seals
Wheel type| Two 4 inch (10.2 cm) non-marking wheels
*Flow rates given are based on chemical with viscosity of water.
Product Components
Get to know the SP-BP-5N components that you will need to use, adjust or assemble.
Back plate assembly • Inside view
- In-line strainer
- Electric fluid pump
- Relay controller
- Pressure switch
- Back plate thumb nuts
Tank Assembly
Front view
- Handle
- Solution tank 14
- Cap
- Discharge wand
- Trigger gun
- Discharge hose
- Power button
- Battery
- Battery box
Operating Instructions
- Remove battery and charger from packaging. Battery must be fully charged before Refer to charge level indicator table in battery user manualfor more information. 5
- Once fully charged, insert battery into the receiveruntil properly secure. Close lid and secure the latch. 3
Note: Keep battery box lid closed and latched unless accessing battery. Do not operate unit with lid open or damaged.
- Fill tank with pre-mixed solution as directed by the chemical manufacturer, then securely tighten the
- Press the power button to turn on the
- Slowly squeeze trigger handle to begin spraying. Release trigger handle to 4
After Use Instructions
2
Note: For proper handling and disposal procedures refer to chemical SDS.
- Solution should be removed from unit after each use. This can be done in two ways:
- Unthread cap from top of tank and drain solution into an approved
- Place discharge wand into approved container. Activate unit until all solution has been flushed from the
- Press power button to turn off unit. Squeeze trigger handle to relieve remaining
- Before using unit with another chemistry, thoroughly flush with
Operating Instructions
-
Remove battery and charger from packaging. Battery must be fully charged before Refer to charge level indicator table in battery user manual for more information.
-
Once fully charged, insert battery into the receiveruntil properly secure. Close lid and secure the latch.
Note: Keep battery box lid closed and latched unless accessing battery. Do not operate unit with lid open or damaged. -
Fill tank with pre-mixed solution as directed by the chemical manufacturer, then securely tighten the
-
Press the power button to turn on the
-
Slowly squeeze trigger handle to begin spraying. Release trigger handle to
After Use Instructions
Note: For proper handling and disposal procedures refer to chemical SDS.
- Solution should be removed from unit after each use. This can be done in two ways:
- Unthread cap from top of tank and drain solution into an approved
- Place discharge wand into approved container. Activate unit until all solution has been flushed from the
- Press power button to turn off unit. Squeeze trigger handle to relieve remaining
- Before using unit with another chemistry, thoroughly flush with