Balboa Hot Tub Controls: User Guide for TP500 and TP500S Control Panels
- June 7, 2024
- BALBOA
Table of Contents
- BALBOA Control Panels
- TP500 and TP500S Control Panels
- Display Icons
- Main Menus
- Fill it up!
- Spa Behavior
- Temperature and Temp Range
- Mode – Ready and Rest
- Flip (Invert Display)
- Flip (Invert Display)
- Restricting Operation
- Unlocking
- Hold (Standby)
- Adjusting Filtration
- Light Timer Programming
- Preferences
- Preferences
- Utilities and Information
- Additional Utilities
- Utilities – GFCI Test Feature
- Utilities – Fault Log
- General Messages
- Heater-Related Messages
- Reminder Messages
- Read More About This Manual & Download PDF
- FAQ’S
- VIDEO
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
The BALBOA Control Panels User Guide is a comprehensive manual for users of the TP500 and TP500S Control Panels for Balboa hot tub controls. The guide provides detailed information on the standard menu system model for all BP series systems, panel software versions, and display icons. Users can navigate the menu structure using 2 or 3 buttons on the control panel, with some panels having separate WARM and COOL buttons while others have a single Temperature button. The guide also includes instructions for preparation and filling of the hot tub, priming the pumps, and exiting priming mode. Users can learn about spa behavior, including pump operation, circulation pump modes, filtration and ozone, freeze protection, and clean-up cycles. The guide also covers temperature and temp range adjustments, including dual temperature ranges with independent set temperatures. Overall, the BALBOA Control Panels User Guide is an essential resource for users of Balboa hot tub controls to ensure proper usage and maintenance of their hot tubs.
BALBOA Control Panels
BALBOA Control Panels
TP500 and TP500S Control Panels
User Guide for Standard Menu System Model: All BP series systems Panel Model:
TP500 and TP500S Series
Panel Software Version: All versions.
Display Icons
A – Heat
B – Ready Mode
C – Rest Mode
D – bba™2 On
E – WiFi (Cloud Connection)
F – Light
G – Cleanup Cycle
H – Jets 1
I – Jets 2
J – Blower
K – Auxiliary (Jets 3 or )
L – Temperature Range (High / Low)
M – Set (Programming)
N – Filter Cycle (1 or 2 or Both)
O – AM or PM (Time)
MicroSilk® is a registered trademark of Jason International.
Manufactured under one or more of these patents. U.S. Patents: 5332944,
5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052,
6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent:
2373248 other patents both foreign and domestic applied for and pending. All
material copyright of Balboa Water Group.
Main Menus
Navigation
Navigating the entire menu structure is done with 2 or 3 buttons on the
control panel. Some panels have separate WARM (Up) and COOL (Down) buttons,
while others have a single Temperature button. In the navigation diagrams
Temperature buttons are indicated by a single button icon.
Panels that have two Temperature buttons (Warm and Cool) can use both of them
to simplify navigation and programming where a single Temperature icon is
shown.
The MENU/SELECT Button is used to choose the various menus and navigate each
section.
Typical use of the Temperature button(s) allows changing the Set
Temperature while the numbers are flashing in the LCD. The menus can be exited
with certain button presses. Simply waiting for a few seconds will return the
panel operation to normal.
Power-up Screens
Each time the System powers up, a series of numbers is displayed.
After the startup sequence of numbers, the system will enter Priming Mode (See
Page 3).
Key
A temperature button, used for “Action”
Menu/Select button
Indicates Alternating or Progressive Message – every 1/2 second
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
Manufactured under one or more of these patents. U.S. Patents: 5332944,
5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052,
6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent:
2373248 other patents both foreign and domestic applied for and pending. All
material copyright of Balboa Water Group.
Fill it up!
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing and the control system during the filling process. After turning the power on at the main power panel, the top-side panel display will go through specific sequences. These sequences are normal and display a variety of information regarding the configuration of the hot tub control.
Priming Mode – MO19*
This mode will last for 4-5 minutes or you can manually exit the priming mode after the pump(s) have primed.
Regardless of whether the priming mode ends automatically or you manually exit the priming mode, the system will automatically starts normal heating and filtering at the end of the priming mode. During the priming mode, the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or no-flow conditions. Nothing comes on automatically, but the pump(s) can be energized by pushing the “Jets” or “Aux” buttons. If the spa has a Circ Pump, it can be activated by pressing the “Light” button during Priming Mode.
Priming the Pumps
As soon as the above display appears on the panel, push the “Jets” button once
to start Pump 1 in low-speed and then again to switch to high-speed. Also,
push the “Jets 2” or “Aux” button, if you have a 2nd pump, to turn it on. The
pumps will now be running in high-speed to facilitate priming. If the pumps
have not primed after 2 minutes, and water is not flowing from the jets in the
spa, do not allow the pumps to continue to run. Turn off the pumps and repeat
the process. Note: Turning the power off and back on again will initiate a new
pump priming session. Sometimes momentarily turning the pump off and on will
help it to prime. Do not do this more than 5 times. If the pump(s) will not
prime, shut off the power to the spa and call for service.
Important: A pump should not be allowed to run without priming for more than 2
minutes. Under NO circumstances should a pump be allowed to run without
priming beyond the end of the 4-5 minute priming mode. Doing so may cause
damage to the pump and cause the system to energize the heater and go into an
overheat condition.
Exiting Priming Mode
You can manually exit Priming Mode by pressing the “Warm” or “Cool” button.
Note that if you do not manually exit the priming mode as described above, the
priming mode will be automatically terminated after 4-5 minutes. Be sure that
the pump(s) have been primed by this time.
Once the system has exited Priming Mode, the top-side panel will momentarily
display the set temperature but the display will not show the water
temperature yet, as shown below. This is because the system requires
approximately 1 minute of water flowing through the heater to determine the
water temperature and display it.
*MO19 is a Message Code. See Page 18.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
Spa Behavior
Pumps
Press the “Jets” button once to turn pump 1 on or off, and to shift between
low and high speeds if equipped.
If left running, the pump will turn off after a time-out period.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other
pump is on. If the spa is in Ready Mode (See page 6), Pump 1 low may also
activate once in a while for at least 1 minute to detect the spa temperature
(polling) and then to heat to the set
temperature if needed. When the low-speed turns on automatically, it cannot be
deactivated from the panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in one of three different ways:
- The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
- The circ pump stays on continuously, regardless of water temperature.
- A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when another pump or blower is on. The specific Circulation Mode that is used has been determined by the Manufacturer and cannot be changed in the field.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during
filtration. On circ systems, the ozone will run with the circ pump.
The system is factory-programmed with one filter cycle that will run in the
evening (assuming the time-of-day is properly set) when energy rates are often
lower. The filter time and duration are programmable. (See page 10) A second
filter cycle can be enabled as needed.
At the start of each filter cycle, all water devices (other than the primary
pump) will run briefly to purge the plumbing to maintain good water quality.
The term “water devices” includes the Blower.
Freeze Protection
If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and the blower automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending on conditions.
In colder climates, an optional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch. See your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the system. On some systems, you can change this setting. (See the Preferences section on page 12)
Temperature and Temp Range
Adjusting the Set Temperature
When using a panel with Up and Down buttons (Temperature buttons), pressing Up or Down will cause the temperature to flash. Pressing a temperature button again will adjust the set temperature in the direction indicated on the button. When the LCD stops flashing, the spa will heat to the new set temperature when required.
If the panel has a single temperature button, pressing the button will cause the temperature to flash. Pressing the button again will cause the temperature to change in one direction (e.g. UP). After allowing the display to stop flashing, pressing the Temperature Button will cause the temperature to flash and the next press will change the temperature in the opposite direction (e.g. DOWN).
Press-and-Hold
If a Temperature button is pressed and held when the temperature is flashing, the temperature will continue to change until the button is released. If only one temperature button is available and the limit of the Temperature Range is reached when the button is being held, the progression will reverse direction.
Dual Temperature Ranges
This system incorporates two temperature range settings with independent set temperatures. The High Range designated in the display by a thermometer and an “up” arrow, and the Low Range designated in the display by a thermometer and “down” arrow.
These ranges can be used for various reasons, with a common use being a “ready to use” setting vs. a “vacation” setting. The Ranges are chosen using the menu structure below. Each range maintains its own set temperature as programmed by the user. This way, when a range is chosen, the spa will heat to the set temperature associated with that range.
For example:
More specific Temp Ranges may be determined by the Manufactur High Range
might be set between 80°F and 104°F. Low Range might be set between 50°F and
99°F.
Freeze Protection is active in either range.
See Ready and Rest on Page 6
for additional heating control information
Mode – Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the “primary pump.”
The primary pump can be either a 2-Speed Pump 1 or a circulation pump.
If the primary pump is a 2-Speed Pump 1, Ready Mode (indicated by ) will
circulate water periodically, using Pump 1 Low, in order to maintain a
constant water temperature, heat as needed, and refresh the temperature
display. This is known as “polling.”
Rest Mode (indicated by ) will only allow heating during programmed filter
cycles. Since polling does not occur, the temperature display
may not show a current temperature until the primary pump has been running for
a minute or two. Circulation Mode (See Page 4, under Pumps, for other
circulation modes)
If the spa is configured for 24HR circulation, the primary pump generally runs
continuously. Since the primary pump is always running, the
spa will maintain set temperature and heat as needed in Ready Mode, without
polling.
In Rest Mode, the spa will only heat to set temperature during programmed
filter times, even though the water is being filtered constantly
when in Circulation Mode.
Key
Indicates Flashing or Changing Segment Key A temperature button, used for “Action” Menu/Select button Indicates Alternating or Progressive Message – every 1/2 second Waiting time that keeps the last change to a menu item. Waiting time (depends on menu item) that reverts to original setting and ignores any change to that menu item.
Ready-in-Rest Mode
appears in the display if the spa is in Rest Mode and “Jets” is pressed. It is assumed that the spa is being used and will heat to set temperature. The primary pump will run until set temperature is reached, or 1 hour has passed. After 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and changing the Mode.
Flip (Invert Display)
Be sure to set the Time-of-Day
Setting the time-of-day can be important for determining filtration times and
other background features. When in the TIME menu, SET TIME will flash on the
display if no time-of-day is set in the memory.
24-hour time display can be set under the PREF menu. (See Page 12)
**
**
Note:
This note refers to systems that do not keep track of Time-of-Day when powered
down.
If power is interrupted to such a system, Time-of-Day is not stored. The
system will still operate and all other user settings will be stored. If
filter cycles are required to run at a particular time of day, resetting the
clock will return the filter times to the actual programmed periods.
When such a system starts up, it defaults to 12:00 Noon, so another way to get
filter times back to normal is to start up the spa at noon on any given day.
SET TIME will still flash in the TIME Menu until the time is actually set, but
since the spa started at noon, the filter cycles will run as programmed.
Flip (Invert Display)
Restricting Operation
The control can be restricted to prevent unwanted use or temperature
adjustments.
Locking the panel prevents the controller from being used, but all automatic
functions are still active.
Locking the Temperature allows Jets and other features to be used, but the Set
Temperature and other programmed settings cannot be adjusted.
Temperature Lock allows access to a reduced selection of menu items. These
include Set Temperature, FLIP, LOCK, UTIL, INFO and FALT LOG.
Unlocking
This Unlock sequence may be used from any screen that may be displayed on a restricted panel.
NOTE: If the panel has both an UP and a Down button, the ONLY button that will
work in the Unlock Sequence is the UP button.
The temperature will not Unlock if the Unlock sequence is done while the panel
is displaying “LOCK”.
Hold (Standby)
Hold Mode –MO37*
Hold Mode is used to disable the pumps during service functions like cleaning
or replacing the filter. Hold Mode will last for 1 hour unless the mode is
exited manually.
Drain Mode
Some spas have a special feature that allows a pump to be employed when
draining the water.
When available, this feature is a component of Hold Mode. Drain Mode will time
out with Hold Mode.
Adjusting Filtration
Main Filtration
Filter cycles are set using a start time and a duration. Start time is indicated by an “A” or “P” in the bottom right corner of the display. Dura- tion has no “A” or “P” indication. Each setting can be adjusted in 15-minute increments. The panel calculates the end time and displays it automatically.
Filter Cycle 2 – Optional Filtration
Filter Cycle 2 is OFF by default.
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will
shorten overall filtration by the overlap amount.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle. If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin.
Light Timer Programming
Light Timer Option
If LITE TIMR does not appear in the Main Menu, the Light Timer feature is not
enabled by the manufacturer.
When available, the Light Timer is OFF by default.
Preferences
F / C (Temp Display)
Change the temperature between Fahrenheit and Celsius.
12 / 24 (Time Display)
Change the clock between 12 hr and 24 hr display.
RE-MIN-DERS (Reminders)
Turn the display of reminder messages (like “Clean Filter”) On or Off.
Note: Reminders continue to run in the background even when not displayed. So
turning the display of Reminders On or Off does not reset any Reminder counts.
CLN-UP (Cleanup)
Cleanup Cycle Duration is not always enabled, so it may not appear. When it is
available, set the length of time Pump 1 will run after each use. 0-4 hours
are available.
M8
(This message may not appear on all systems.) On systems that have M8, it is enabled by default. It can be disabled (or re-enabled) here. M8 reduces polling intervals when the water temperature in the spa is steady.
DOL-PHIN-AD-DRES (Dolphin II and Dolphin III) Applies to RF Dolphin only.
(This message may not appear depending on the configuration)
When set to 0, no addressing is used. Use this setting for a Dolphin Remote
which is factory set for no address by default. When set between 1 and 7, the
number is the address. (See the Dolphin manual for details.)
Preferences
Utilities and Information
INFO (System Information sub-menu)
The System Information Menu displays various settings and identification of the particular system.
SSID (Software ID)
Displays the software ID number for the System.
MODL (System Model)
Displays the Model Number of the System.
SETP (Current Setup)
Displays the currently selected Configuration Setup Number.
Heater Voltage (Feature not used on CE rated systems.)
Displays the operating voltage configured for the heater.
Heater Wattage as Configured in Software (CE Systems Only.)
Displays a heater kilowatt rating as programmed into the control system
software (1-3 or 3-6).
_H __ (Heater Type)
Displays a heater type ID number.
_SW __ (Dip Switch Settings)
Displays a number that represents the DIP switch positions of S1 on the main circuit board.
PANL (Panel Version)
Displays a number of the software in the topside control panel.
Additional Utilities
Utilities
In addition to INFO, The Utilities Menu contains the following:
GFCI (GFCI Test)
(Feature not available on CE rated systems.)
GFCI Test is not always enabled, so it may not appear. This screen allows the
GFCI to be tested manually from the panel and can be used to reset the
automatic test feature. If the GFCI Test Feature is reset, the device will
trip within 7 days. (See Page 17)
A / B (A/B Sensor Temperatures)
When this is set to On, the temperature display will alternate to display temperature from Sensor A and Sensor B in the heater.
FALT LOG (Fault Log)
The Fault Log is a record of the last 24 faults that can be reviewed by a service tech.
DEMO (Demo Mode)
Demo Mode is not always enabled, so it may not appear. This is designed to operate several devices in a sequence in order to demon- strate the various features of a particular hot tub.
Utilities
Utilities – GFCI Test Feature
Forcing the GFCI Trip Test
Waiting a few seconds inside the GFCI Menu will allow the screen to return to
normal operation.
The installer can cause the GFCI Trip Test to occur sooner by initiating it
using the above menu.
The GFCI should trip within a few seconds and the spa should shut down. If it
does not, shut down the power and manually verify that a GFCI breaker is
installed and that the circuit and spa are wired correctly. Verify the
function of the GFCI with its own test button. Restore power to the spa and
repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will operate
normally from that point. You can verify a successful test by navigating to
the above menu. PASS should appear after a temp button is pressed from the
GFCI screen.
The end-user must be trained to expect this one-time test to occur and how to
properly reset the GFCI.
Warning:
If freezing conditions exist, a GFCI should be reset immediately or spa damage could result. The end user should always be trained to test and reset the GFCI on a regular basis.
Utilities – Fault Log
A Little History can tell a lot The Fault Log stores up to 24 events in memory and they can be reviewed under the Fault Log Menu. Each event captures a Fault Message Code, how many days have passed since the fault, Time of the fault, Set Temperature during the fault, and Sensor A and B temperatures during the fault.
General Messages
Priming Mode – MO19
Each time the spa is powered up, it will enter Priming Mode. The purpose of
Priming Mode is to allow the user to run each pump and manually verify that
the pumps are primed (air is purged) and water is flowing. This typically
requires observing the output of each pump separately, and is generally not
possible in normal operation. Priming Mode lasts 4 minutes, but you can exit
it earlier by pressing any Temp button. The heater is not allowed to run
during Priming Mode.
NOTE: If your spa has a Circ Pump, it will turn on with “Light” in Priming
Mode. The Circ Pump will run by itself when Priming Mode is exited
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be displayed
Too Cold – Freeze Protection
A potential freeze condition has been detected, or the Aux Freeze Switch has
closed, and all pumps and blower are activated, either one at a time, or all
at once, depending on how your system was built. All pumps and blower are ON
for at least 4 minutes after the potential freeze condition has ended, or when
the aux freeze switch opens.
In some cases, pumps may turn on and off and the heater may operate during
Freeze Protection. This is an operational message, not an error indication.
Water is too Hot (OHS) – MO29
One of the water temp sensors has detected spa water temp 110°F (43.3°C) and spa functions are disabled. System will auto reset when the spa water temp is below 108°F (42.2°C). Check for extended pump operation or high ambient temp
J29 Warning – MO44
J29 is typically used as a Heater Disable input. As such, it should not
typically be shorted at power-up. This message appears if J29 is shorted at
power-up.
Heater-Related Messages
Sensor-Related Messages
Miscellaneous Messages
System-Related Messages
System-Related Messages
Reminder Messages
General maintenance helps.
The display of Reminder Messages can be suppressed by using the PREF Menu. See
Page 12.
Reminder Messages can be chosen individually by the Manufacturer. They may be
disabled entirely, or there may be a limited number of
reminders on a specific model.
The frequency of each reminder (e.g. 7 days) can be specified by the
Manufacturer.
Press a Temperature button to reset a displayed reminder message.
Warning:
If freezing conditions exist, a GFCI or RCD should be reset immediately or spa damage could result. The end user should always trained to test and reset the GFCI or RCD on a regular basis.
Reminder Messages Continued
Warning! Qualified Technician Required for Service and Installation
Basic Installation and Configuration Guidelines
Use minimum 6AWG copper conductors only.
Torque field connections between 21 and 23 in lbs.
Readily accessible disconnecting means to be provided at time of installation.
Permanently connected.
Connect only to a circuit protected by a Class A Ground Fault Circuit
Interrupter (GFCI) or Residual Current Device (RCD) mounted at least 5’
(1.52M) from the inside walls of the spa/hot tub and in line of sight from the
equipment compartment.
CSA enclosure: Type 2
Refer to Wiring Diagram inside the cover of the control enclosure.
Refer to Installation and Safety Instructions provided by the spa
manufacturer.
Warning : People with infectious diseases should not use a spa or hot
tub.
Warning : To avoid injury, exercise care when entering or exiting the spa
or hot tub.
Warning : Do not use a spa or hot tub immediately following strenuous
exercise
Warning : Prolonged immersion in a spa or hot tub may be injurious to
your health
Warning : Maintain water chemistry in accordance with the Manufacturers
instructions.
Warning : The equipment and controls shall be located not less than 1.5
meters horizontally from the spa or hot tub.
Warning! GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD on a regular basis to verify
its function.
Warning! Shock Hazard!
No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service
organization for assistance. Follow all owner’s manual power connection
instructions. Installation must be performed by a licensed electrician and all
grounding connections must be properly installed.
CSA Compliance/Conformité
Caution:
- Test the ground fault circuit interrupter or residual current device before each use of the spa.
- Read the instruction manual.
- Adequate drainage must be provided if the equipment is to be installed in a pit.
- For use only within an enclosure rated CSA Enclosure 3.
- Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device.
- To ensure continued protection against shock hazard, use only identical replacement parts when servicing.
- Install a suitably rated suction guard to match the maximum flow rate marked.
Warning :
- Water temperature in excess of 38°C may be injurious to your
- Disconnect the electrical power before
Read More About This Manual & Download PDF
FAQ’S
I do not see the WiFi icon on my display.
The WiFi icon will appear on the display if the TP500/TP500S is connected to a wireless network.
I do not see the Cleanup Cycle icon on my display.
The Cleanup Cycle icon will appear on the display if a bba™2 device is connected to the TP500/TP500S and if there are no other programming icons running.
What is the difference between a TP300 and a TP400?
The only difference between these two models is that they have different control panel software versions installed in them. A TP400 has software version V1.0 while a TP300 has software version V1.1 installed in it. Both of these models have exactly the same hardware inside of them so they will perform exactly the same way when they are connected to water supply lines and operating in their normal modes of operation (i.e., not in test mode).
How do I reset my Balboa hot tub control panel?
At 107¡F (approximately 41.7¡C), the spa should automatically reset. If spa does not reset, shut off the power to the spa. Standby Mode has been activated by pressing a button combination on the user panel. Press any button to leave Standby Mode and return to normal operation.
How do I know if my hot tub control panel is bad?
Control Panel is Not Working
If only a part is not working, look for error messages or blinking lights. As
a first step, reset your breaker. If the problem persists, turn the breaker
off and disconnect the panel to examine the circuit board. Turn the power on
and check if the hot tub heats up or starts to filter.
Can you turn off a hot tub when it is not in use?
Have you ever wondered if you are able to turn off your hot tub when it is not in use? Well, yes you can.
Do hot tubs use a lot of electricity?
Modern manufacturers advertise the cost to run their hot tubs at about one dollar per day, with $50 per month at the high end. The energy cost of a hot tub varies based mainly on the heater, which usually draws between 1,500 watts or 6,000 watts. The pump is another prime energy user at 1,500 watts.
What happens if you leave a hot tub open overnight?
If you leave your hot tub uncovered for long periods of time then much of the water will be lost to steam. By keeping your hot tub covered with a high quality hot tub cover, when it is not in use, the steam condenses back into water on the underside of your hot tub cover and is returned to the spa to be reheated again.
Can I change my hot tub control panel?
Are you struggling to replace your hot tub’s expensive and hard to find circuit board or topside controller? Instead of hauling your old spa off to the dump, consider installing an entirely new control system! Installation is simple for someone with average mechanical skills.
How do you change modes on a Balboa hot tub?
Depending on system configuration, mode changing may not be available and will be locked in Standard Mode. Mode is changed by pressing “Temp,” then “Light”. Standard Mode maintains set temperature. will be displayed momentarily when you switch into Standard Mode.
What setting should hot tub be on?
According to the US Consumer Product Safety Commission, the water temperature of a hot tub is best between 100°F and 102°F.
How can I lower my electric bill in my hot tub?
Here’s a few ways to curb your spa’s appetite for energy. ADD WIND BLOCKS. CLOSE THE AIR JETS. TURN OFF THE BLOWER.
How do I navigate the menu structure on the Balboa hot tub control panel?
You can navigate the menu structure using 2 or 3 buttons on the control panel, with some panels having separate WARM and COOL buttons while others have a single Temperature button.
What is Priming Mode on the Balboa hot tub control panel?
Priming Mode lasts for 4-5 minutes or until you manually exit it after the pump(s) have primed. During Priming Mode, the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low-flow or no-flow conditions.
How do I prime the pumps on my Balboa hot tub control panel?
As soon as the Priming Mode display appears on the panel, push the “Jets” button once to start Pump 1 in low-speed and then again to switch to high- speed. Also, push the “Jets 2” or “Aux” button, if you have a 2nd pump, to turn it on.
What is Freeze Protection on the Balboa hot tub control panel?
If the temperature sensors within the heater detect a low enough temperature, then the pump(s) and the blower automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending on conditions.
Can I adjust the temperature range on my Balboa hot tub control panel?
Yes, you can adjust the temperature range by pressing and holding the “Temperature Range” button.
What is the Clean-up Cycle on the Balboa hot tub control panel?
When a pump or blower is turned on by a button press, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the system.
How do I adjust the filter cycle on my Balboa hot tub control panel?
The filter time and duration are programmable. See page 10 of the user guide for instructions on how to adjust the filter cycle.
What is the purpose of the Circulation Pump on the Balboa hot tub control panel?
The Circulation Pump helps to maintain good water quality by running continuously or periodically depending on the system.
How do I exit Priming Mode on my Balboa hot tub control panel?
You can manually exit Priming Mode by pressing the “Warm” or “Cool” button. Note that if you do not manually exit the priming mode as described above, the priming mode will be automatically terminated after 4-5 minutes.
FIND THE PUMP RUN TIME SWEET SPOT. TURN DOWN THE SPA HEATER: RUN YOUR SPA DURING OFF-PEAK HOURS: USE A BETTER OR BEST SPA COVER. TIGHTEN UP YOUR SPA COVER.