SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual

June 16, 2024
SIEMENS

SIEMENS RDZ100ZB Zigbee Room Thermostat

SIEMENS RDZ100ZB Zigbee Room Thermostat

For heating systems

  • Room temperature control
  • Communicates with Connected Home Hub via ZigBee network
  • 2-position/TPI control with On/Off output for heating
    • RDZ100ZB: With built-in relay
    • RDZ101ZB: With wireless output module
  • Open window detection
  • Frost protection
  • Schedule via mobile application “Connected Home” (downloadable from Google Play™ or Apple App Store®)
  • Adjustable commissioning and control parameters via mobile application
  • Battery-powered (2xAA batteries)

Use

The RDZ100ZB/RDZ101ZB is part of Siemens Connected Home ecosystem. It is used to control the room temperature in heating systems.
Typical application:

  • Apartments
  • Single family homes

To control the following pieces of equipment:

  • Thermal valves or zone valves
  • Gas or oil boilers
  • Heat pumps
  • Circulating pumps
  • Floor heating

Functions

  • Room temperature control via built-in sensor

  • Selection of operating mode “On” or “Off” (frost protection)

  • Setting schedule via the mobile application

  • Display of current room temperature

  • Setpoint override (manual mode) until the next scheduled switching point

  • Limitation of minimum/maximum setpoint adjustments for heating

  • Remote operation and monitoring via mobile application

  • Open window detection

  • Valve exercising

  • Heat demand-based boiler or pump release in combination with e.g. Connected Home
    Receiver RCR110.2ZB

  • Factory reset

  • Wireless communication

  • Firmware upgrade via ZigBee

  • Auto sleep function to save battery

Type summary

Type Stock number Description
RDZ100ZB S55772-T113 Wired, heating, battery powered
RDZ101ZB S55772-T114 Wireless, heating, battery powered
RCR110.2ZB S55772-T110 Wireless output module for RDZ101ZB

Accessories

Type Stock number Description
ARG101 S55772-T112 Italian adapter plate for RDZ100ZB and RDZ101ZB

Delivery

RCR110.2ZB and ARG101 are not included in the delivery and must be ordered separately.

Inbox item

RDZ100ZB

Items Quantity
RDZ100ZB mounting plate 1
RDZ100ZB front panel 1
Battery 2
Mounting instructions 1

RDZ101ZB

Items Quantity
RDZ101ZB mounting plate 1
RDZ101ZB table stand 1
RDZ101ZB front panel 1
Battery 2
Mounting instructions 1

Equipment combinations

Type of unit| Product number| **Data Sheet*| Use with the type of temperature control**
---|---|---|---
Electro motoric actuator|


| SFA21…| 4863| 2-position & TPI slow
Thermal actuator (for radiator valves)

AC 230 V, NO

|


| STP321| A6V12986007| 2-position & All TPI
Thermal actuator AC 230 V (for small valves 2.5 mm), NC|


| STA321| A6V12986007| 2-position & All TPI
Damper actuator|


| GDB…| 4634| 2-position & TPI slow
Damper actuator|


| GSD…| 4603| 2-position & TPI slow
Damper actuator| | GQD…| 4604| 2-position & TPI slow
Rotary damper actuator|
| GXD…| 4622| 2-position & TPI slow

The documents can be downloaded from www.siemens.com/bt/download.

Product documentation

Title Document ID
Mounting instructions A6V13360576
Operation manual A6V13360586
CE declaration A5W00270102A
UKCA declaration A5W00270107A
Product environmental declaration A5W00269582A
Siemens Connected Home system description A6V13661932

Related documents such as environmental declarations, CE declarations, and so on, can be downloaded at: http://siemens.com/bt/download.

Notes

Safety

  CAUTION



| National safety regulations
Failure to comply with national safety regulations may result in personal injury and property damage.

  • Observe national provisions and comply with the appropriate safety regulations.

  WARNING


**| Explosion due to fire or short-circuit, even with discharged batteries
** Risk of injury due to flying parts

  • Prevent the batteries from coming in contact with water.
  • Do not recharge batteries.
  • Do not damage or disassemble batteries.
  • Do not heat batteries over 60 °C.

  WARNING



| Electrolyte leakage
Chemical burns

  • Only grasp damaged batteries using suitable protective gloves.
  • If electrolyte comes into contact with eyes, immediately rinse eyes with plenty of water. Consult a doctor.

Mounting

Mounting

Mounting

  • RDZ100ZB is suitable for wall mounting.
  • RDZ101ZB is suitable for wall mounting and table standing.
  • Recommended height for wall mounting: 1.50 m above the floor.
  • Mount the thermostat close to Connected Home Hub if possible. Note that the communication range can vary because walls, floors, wireless interference and other factors may reduce the signal strength.
  • Do not mount or place the thermostat in recesses, behind curtains or doors, or above or near heat sources.
  • Do not mount or place the thermostat near large metal structures or other construction elements with fine metal meshes like special glass or special concrete.
  • Do not mount or place the thermostat in a location where it is exposed to dripping water, moisture or excessive heat.
  • Do not mount or place the thermostat on metal surfaces.
  • Avoid placing RDZ101ZB inside or near metal or sources of radio or electromagnetic energy or interference, for example, do not place under or on top of a WLAN router.
  • Avoid direct sunlight.
  • Seal the conduit box or the installation tube if any, as air currents can affect sensor readings.
  • Observe allowed ambient conditions.
  • Keep the thermostat out of the reach of people (including children) whose physical, sensory or mental capabilities, knowledge, or experience prevents them from using the thermostat safely without supervision or instructions.
  • If the adapter plate ARG101 is used, assemble its mounting frame and mounting plate in such a way that the bigger round spot embossed on the mounting frame is atop.

Wiring (for RDZ100ZB only)

  • Make sure wiring, protection, and earthing comply with local regulations.
  • Switch off power to the heating system before mounting/dismantling and wiring.
  • Correctly size the cables to the thermostat and the valve actuators.
  • Use only valve actuators rated for AC 24…230 V.
  • External preliminary protection with maximum C 10 A circuit breaker in the supply lines is required under all circumstances.

Installation

  WARNING


**| No internal line protection for supply lines to external consumers
** Risk of fire and injury due to short-circuits

  • Adapt the line diameters as per local regulations to the rated value of the installed fuse.

  CAUTION


| Risk of explosion
Personal injury and property damage

  • Insert the battery at the correct polarity (+/-) using the illustration in the battery compartment.
  • Insert only the correct battery types according to the indication in the battery compartment.
  • Store, transport and dispose of the batteries in compliance with local requirements, regulations and laws, and observe the instructions of the battery manufacturer.

Observe the following:

  • The batteries must be undamaged.
  • Do not mix new and used batteries.

Commissioning

  • The thermostat is ready for commissioning after batteries are inserted.
  • After joining is initiated from the mobile application, tap and hold for more than five seconds on the thermostat to join the ZigBee network.
  • After joining the network, set schedules and change parameters in the mobile application to ensure optimum performance of the entire system. See the operation manual (http://www.siemens.com/download?A6V13360586) for more information about parameters.

Wireless output module

The wireless room thermostat RDZ101ZB requires a wireless output module, e.g.
RCR110.2ZB, to control HVAC equipment. Binding the thermostat to the output module is automatic, if located in the same room. Max. 5 wireless output modules can be bound to one wireless room thermostat RDZ101ZB.

Operation

*See the operation manual (http://www.siemens.com/download?A6V13360586) for detailed information.

Maintenance

Apart from replacing batteries upon low battery notification on the local screen or in the mobile application, the thermostat is maintenance-free. See the operation manual (http://www.siemens.com/download?A6V13360586) for information about battery replacement.

Open Source Software (OSS)

Software license overview
These devices use Open Source Software (OSS). All Open Source Software components used in the product (including copyrights and licensing agreement) are available at http://siemens.com/bt/download.

Firmware version OSS document ID Device
v10000 A6V13562630 RDZ100ZB, RDZ101ZB

Disposal

This symbol or any other national label indicate that the product, its packaging, and, where applicable, any batteries may not be disposed of as domestic waste. Delete all personal data and dispose of the item(s) at separate collection and recycling facilities in accordance with local and national legislation.
For additional details, refer to Siemens information on disposal.

Warranty

Technical data on specific applications are valid only together with Siemens products listed under Equipment combinations [▶ 3]. Siemens rejects any and all warranties in the event that third-party products are used.

General technical data

Power supply

Operating voltage| DC 3 V (2 x 1.5 V AA alkaline batteries)
Battery life| 1 year
Radio parameters

Frequency band| 2.4…2.4835 GHz
Maximum radio-frequency power| 6 dBm
Communication standard| Based on ZigBee 3.0
MAC protocol| IEEE 802.15.4
ZigBee channels| 11…26
Pairing method with GTW100ZB| Global Link Key
Functional data

Protection mode| 8 °C
Built-in room temperature sensor
Setpoint setting range| 5…35 °C
Accuracy at 25 °C| < ±0.5 K
Temperature calibration range| ±2.5 K
Resolution of settings and displays
Setpoints| 0.5 °C
Temperature value displays| 0.5 °C
Ambient conditions and protection classification

Degree of protection of housing as per EN 60529| IP30
Protection against electrical shock
RDZ100ZB| Protection class II
RDZ101ZB| Protection class III
Classification as per EN 60730
Function of automatic control devices| Type 1
Degree of pollution| 2
Ambient conditions and protection classification

Overvoltage category
RDZ100ZB| III
RDZ101ZB| I
Rated impulse voltage
RDZ100ZB| 4000 V
RDZ101ZB| 330 V
Climatic ambient conditions
Transport and storage (in packaging)|

  • Temperature: -25…+70 °C (-13…+158 °F)
  • Ambient humidity: < 95 % r.h. (non-condensing)

Operation (in dry locations having no temperature or humidity control)|

  • Temperature: 0…50 °C (32…122 °F)
  • Ambient humidity: < 95 % r.h. (non-condensing)

Mechanical ambient conditions
Transport (in transport packaging) as per IEC/EN 60721-3-2| Class 2M4
Operation as per IEC/EN 60721-3-3| Class 3M11
Standards, directives and approvals

EU conformity (CE)| See EU declaration of conformity A5W00270102A)
UK conformity (UKCA)| See UK-declaration of conformity A5W00270107A
)
Environmental compatibility| The product environmental declaration (A5W00269582A) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal).

*The documents can be downloaded from www.siemens.com/bt/download.

General

Housing color| RAL9003
Thermostat with box, user document and accessory
RDZ100ZB| 210 g
RDZ101ZB| 226 g
General

Thermostat
RDZ100ZB| 157 g
RDZ101ZB| 173 g

Technical data (RDZ100ZB only)

Switching capacity of relay

Voltage| AC 24…230 V
Current| Lx – L1 Maximum 5 (2) A Lx – L2 Maximum 5 (2) A

  WARNING


**| No internal fuse.**

External preliminary protection with maximum C 10 A circuit breaker in the supply lines is required under all circumstances.

External protection for incoming cable

Circuit breaker| Maximum 10 A
Circuit breaker tripping characteristic| Type B, C or D as per EN 60898 and EN 60947
Contact life at AC 230 V At 5 A res.| Guided value: 1 x 105 cycles
Electrical connections

Connection terminals| Screw terminals
For solid wires or prepared stranded wires| 2 x 1.5 mm2 or 1 x 2.5 mm2 (min. 0.5 mm2)

Connection diagrams

RDZ100ZB

Connection diagrams

Lx Live, AC 24…230 V
Lx, L2 NC contact (for NO valves)
Lx , L1 NO contact (for NC valves)
Nx Neutral conductor, AC 24…230 V
N1 Wired room thermostat RDZ100ZB
Y1 Actuating device

  WARNING


| Current higher than 5(2) A is not allowed to go through RDZ100ZB controller. For high current device, an additional relay or contactor must be installed.

RDZ101ZB

Connection diagrams

L Live, AC 230 V
Lx Live, AC 24…230 V
Q11 , Q12 NC contact (for NO valves)
Q11 , Q14 NO contact (for NC valves)
N Neutral conductor, AC 230 V
Nx Neutral conductor, AC 24…230 V
N1 Wireless room thermostat RDZ101ZB
N2 Wireless output module RCR110.2ZB
Y1 Actuating device

Application examples

RDZ100ZB RDZ101ZB (with RCR110.2ZB)

Gas boiler

| Gas boiler

Floor heating with valve

Application examples

| Floor heating with valve

Application examples

Radiator with pump

Application examples

| Floor heating with pump

Application examples

Electric boiler

Application examples

| Electric boiler

Application examples

Electric radiator

Application examples

N1 RDZ100ZB/RDZ101ZB
N2 RCR110.2ZB
M1 Circulating pump
K1 Heat generator (for example, boiler)
Y1 Magnetic valve

Dimensions

Dimensions

Regulatory compliance information

Radio equipment directive
The equipment uses harmonized frequency in Europe and complies with Radio Equipment Directive 2014/53/EU (formerly 1999/5/EC).

CUSTOMER SUPPORT

Issued by
Siemens Switzerland Ltd
Smart Infrastructure
Global Headquarters
Theiler Strasse 1a
CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies
© Siemens 2023
Technical specifications and availability subject to change without notice.
Document ID A6V13360592_en–_c
Edition 2023-10-09Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals