TP500 and TP500S Control Panels
User Guide for Simplified Menu
System Model: All BP series systems that support Simplified Menus
Panel Model: TP500 and TP500S Series
Panel Software Version: All versions
Display Icons
A – Heat
B – Ready Mode
C – Rest Mode
D – bba™2 On
E – WiFi (Cloud Connection)| FLight
G – Cleanup Cycle
H – Jets 1
I – Jets 2
J – Blower| K – Auxiliary (Jets 3 or)
L – Temperature Range (High / Low)
M – Set (Programming)
N – Filter Cycle (1 or 2 or Both)
---|---|---
MicroSilk® is a registered trademark of Jason International.
Main Menus
Navigation
Navigating the entire menu structure is done with 2 or 3 buttons on the
control panel.
Some panels have separate WARM (Up) and COOL (Down) buttons, while others have a single Temperature button. In the navigation diagrams, Temperature buttons are indicated by a single button icon. Panels that have two Temperature buttons (Warm and Cool) can use both of them to simplify navigation and programming where a single Temperature icon is shown.
The MENU/SELECT Button is used to choose the various menus and navigate each
section.
Typical use of the Temperature button(s) allows changing the Set Temperature
while the numbers are flashing in the LCD. The menus can be exited with
certain button presses. Simply waiting for a few seconds will return the panel
operation to normal.
Power-up Screens
Each time the System powers up, a series of numbers is displayed. After the
startup sequence of numbers, the system will enter Priming Mode (See Page 3).
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting for time (depends on menu item) that reverts to the original setting
and ignores any change to that menu item.
Main Screen
Waiting a few seconds in the Main Menu will allow the display to revert to the Main Screen. Most changes are not saved unless Menu/Select is pressed. Refer to key above.
Fill it up!
Preparation and Filling
Fill the spa to its correct operating level. Be sure to open all valves and
jets in the plumbing system before filling to allow as much air as possible to
escape from the plumbing and the control system during the filling process.
After turning the power on at the main power panel, the top-side panel display
will go through specific sequences. These sequences are normal and display a
variety of information regarding the configuration of the hot tub control.
Priming Mode
This mode will last for 4-5 minutes or you can manually exit the priming mode
after the pump(s) have primed.
Regardless
of whether the priming mode ends automatically or you manually exit the
priming mode, the system will automatically starts normal heating and
filtering at the end of the priming mode. During the priming mode, the heater
is disabled to allow the priming process to be completed without the
possibility of energizing the heater under low-flow or no-flow conditions.
Nothing comes on automatically, but the pump(s) can be energized by pushing
the “Jets” or “Aux” buttons.
If the spa has a Circ Pump, it can be activated by pressing the “Light” button during Priming Mode.
Priming the Pumps
As soon as the above display appears on the panel, push the “Jets” button once
to start Pump 1 in low-speed and then again to switch to high-speed. Also,
push the “Jets 2” or “Aux” button, if you have a 2nd pump, to turn it on. The
pumps will now be running in high-speed to facilitate priming. If the pumps
have not primed after 2 minutes, and water is not flowing from the jets in the
spa, do not allow the pumps to continue to run. Turn off the pumps and repeat
the process. Note: Turning the power off and back on again will initiate a new
pump-priming session. Sometimes momentarily turning the pump off and on will
help it to prime. Do not do this more than 5 times. If the pump(s) will not
prime, shut off the power to the spa and call for service. Important: A pump
should not be allowed to run without priming for more than 2 minutes. Under NO
circumstances should a pump be allowed to run without priming beyond the end
of the 4-5 minute priming mode. Doing so may cause damage to the pump and
cause the system to energize the heater and go into an overheat condition.
Exiting Priming Mode
You can manually exit Priming Mode by pressing the “Warm” or “Cool” button.
Note that if you do not manually exit the priming mode as described above, the
priming mode will be automatically terminated after 4-5 minutes. Be sure that
the pump(s) have been primed by this time. Once the system has exited Priming
Mode, the top-side panel will momentarily display the set temperature but the
display will not show the water temperature yet, as shown below. This is
because the system requires approximately 1 minute of water flowing through
the heater to determine the water temperature and display it.
Spa Behavior
Pumps
Press the “Jets” button once to turn pump 1 on or off, and to shift between
low and high speeds if equipped. If left running, the pump will turn off after
a time-out period.
On non-circ systems, the low-speed of pump 1 runs when the blower or any other pump is on. If the spa is in Ready Mode (See page 6), Pump 1 low may also activate once in a while for at least 1 minute to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low- speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in
one of three different ways:
- The circ pump operates continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).
- The circ pump stays on continuously, regardless of water temperature.
- A programmable circ pump will come on when the system is checking temperature (polling), during filter cycles, during freeze conditions, or when another pump or blower is on. The specific Circulation Mode that is used has been determined by the manufacturer and cannot be changed in the field.
Filtration and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during
filtration. On circ systems, the ozone will run with the circ pump. Most spas
have one filter cycle per day, but some spas have two filter cycles per day.
The first filter cycle occurs 6 minutes after power-up and then every 24
hours. The second filter cycle, if there is one, occurs 12 hours after the
first one. The filter duration is programmable. (See page 7.) At the start of
each filter cycle, all water devices (other than the primary pump) will run
briefly to purge the plumbing to maintain good water quality. The term “water
devices” includes the Blower.
Freeze Protection
If the temperature sensors within the heater detect a low enough temperature,
then the pump(s) and the blower automatically activate to provide freeze
protection. The pump(s) and blower will run either continuously or
periodically depending on conditions. In colder climates, an optional freeze
sensor may be added to protect against freeze conditions that may not be
sensed by the standard sensors. Auxiliary freeze sensor protection acts
similarly except with the temperature thresholds determined by the switch. See
your dealer for details.
Clean-up Cycle (optional)
When a pump or blower is turned on by a button press, a clean-up cycle begins
30 minutes after the pump or blower is turned off or times out. The pump and
the ozone generator will run for 30 minutes or more, depending on the system.
Temperature
Adjusting the Set Temperature
When using a panel with Up and Down buttons (Temperature buttons), pressing Up
or Down will cause the temperature to flash. Pressing a temperature button
again will adjust the set temperature in the direction indicated on the
button. When the LCD stops flashing, the spa will heat to the new set
temperature when required. If the panel has a single temperature button,
pressing the button will cause the temperature to flash. Pressing the button
again will cause the temperature to change in one direction (e.g. UP). After
allowing the display to stop flashing, pressing the Temperature Button will
cause the temperature to flash and the next press will change the temperature
in the opposite direction (e.g. DOWN).
Press-and-Hold
If a Temperature button is pressed and held when the temperature is flashing,
the temperature will continue to change until the button is released. If only
one temperature button is available and the limit of the Temperature Range is
reached when the button is being held, the progression will reverse direction.
Mode Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the “primary pump.”
The primary pump can be either a 2-Speed Pump 1 or a circulation pump.
If the primary pump is a 2-Speed Pump 1, Ready Mode (indicated by R ) will
circulate water periodically, using Pump 1 Low, in order to maintain a
constant water temperature, heat as needed, and refresh the temperature
display. This is known as “polling.”
Rest Mode (indicated by ) will only allow heating during programmed filter cycles. Since polling does not occur, the temperature display may not show a current temperature until the primary pump has been running for a minute or two.
Circulation Mode (See Page 4, under Pumps, for other circulation modes)
If the spa is configured for 24HR circulation, the primary pump generally runs
continuously. Since the primary pump is always running, the spa will maintain
set temperature and heat as needed in Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed
filter times, even though the water is being filtered constantly when in
Circulation Mode.
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
Ready-in-Rest Mode
R appears in the display if the spa is in Rest Mode and “Jets” is
pressed. It is assumed that the spa is being used and will heat to set
temperature. The primary pump will run until set temperature is reached, or 1
hour has passed. After 1 hour, the System will revert to Rest Mode. This mode
can also be reset by entering the Mode Menu and changing the Mode.
Flip (Invert Display)
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting for time (depends on menu item) that reverts to the original setting
and ignores any change to that menu item.
Adjusting Filtration
Main Filtration
Filter cycles are set using a duration. The filter duration setting can be
adjusted in 1-hour increments. Filter Cycle 1 and Filter Cycle 2 (if enabled)
are set to the same duration.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle.
General Messages
Priming Mode
Each time the spa is powered up, it will enter Priming Mode. The purpose of
Priming Mode is to allow the user to run each pump and manually verify that
the pumps are primed (air is purged) and water is flowing. This typically
requires observing the output of each pump separately and is generally not
possible in normal operation. Priming Mode lasts 4 minutes, but you can exit
it earlier by pressing any Temp button. The heater is not allowed to run
during Priming Mode.
NOTE: If your spa has a Circ Pump, it will turn on with “Light” in
Priming Mode. The Circ Pump will run by itself when Priming Mode is exited.
Water
Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be
displayed.
Too Cold – Freeze Protection
A potential freeze condition has been detected, or the Aux Freeze Switch has
closed, and all pumps and blower are activated, either one at a time, or all
at once, depending on how your system was built. All pumps and blower are ON
for at least 4 minutes after the potential freeze condition has ended, or when
the aux freeze switch opens. In some cases, pumps may turn on and off and the
heater may operate during Freeze Protection.
This is an operational message, not an error indication.
Water is too Hot (OHS)
One of the water temp sensors has detected spa water temp 110°F (43.3°C) and
spa functions are disabled. The system will auto-reset when the spa water temp
is below 108°F (42.2°C). Check for extended pump operation or high ambient
temp.
J29 Warning
J29 is typically used as a Heater Disable input. As such, it should not
typically be shorted at power-up. This message appears if J29 is shorted at
power-up.
- This message can be reset from the topside panel with any button press.
Heater-Related Messages
Heater Flow is Reduced (HFL)
There may not be enough water flow through the heater to carry the heat away
from the heating element. Heater startup will begin again after about 1 min.
See “Flow Related Checks” below.
**Heater Flow is Reduced (LF)***
There is not enough water flow through the heater to carry the heat away from
the heating element and the heater has been disabled. See “Flow Related
Checks” below. After the problem has been resolved, you must press any button
to reset and begin heater start up.
**Heater may be Dry (dr)***
Possible dry heater, or not enough water in the heater to start it. The spa is
shut down for 15 min. Press any button to reset the heater start-up. See “Flow
Related Checks” below.
**Heater is Dry***
There is not enough water in the heater to start it. The spa is shut down.
After the problem has been resolved, you must press any button to reset and
restart the heater startup. See “Flow Related Checks” below.
**The
heater is too Hot (OHH)***
One of the water temp sensors has detected 118°f (47.8°C) in the heater and
the spa is shut down. You must press any button to reset when water is below
108°f (42.2°C). See “Flow Related Checks” below.
A
Reset Message may Appear with other Messages.
Some errors may require power to be removed and restored.
Flow-Related Checks
Check for low water level, suction flow restrictions, closed valves, trapped
air, too many closed jets and pump prime.
On some systems even when spa is shut down, some equipment may occasionally turn on to continue monitoring temperature or if freeze protection is needed.
- This message can be reset from the topside panel with any button press.
Sensor-Related Messages
Sensor Balance is Poor
The temperature sensors MAY be out of sync by or 3°F. Call for Service.
**Sensor Balance is Poor***
The temperature sensors ARE out of sync. The Sensor Balance is Poor fault has
been established for at least 1 hour. Call for Service.
Sensor Failure Sensor A, Sensor B
A temperature sensor or sensor circuit has failed. Call for Service.
Miscellaneous Messages
No Communications
The control panel is not receiving communication from the System. Call for
Service.
– Pre-
Production Software
The Control System is operating with test software. Call for Service.
The Control System is in Test Mode. Call for Service.
- This message can be reset from the topside panel with any button press.
System-Related Messages
**Memory Failure –
Checksum Error***
At Power-Up, the system has failed the Program Checksum Test. This indicates a
problem with the firmware (operation program) and requires a service call.
Memory Warning – Persistent
Memory Reset
Appears after any system setup change. Contact your dealer or service
organization if this message appears on more than one power-up, or if it
appears after the system has been running normally for a period of time.
Memory Failure – Clock
Error
Contact your dealer or service organization.
Configuration Error Spa will not
Start Up
Contact your dealer or service organization.
GFCI Failure – System Could Not Test/Trip the GFCI
NORTH AMERICA ONLY. May indicate an unsafe installation. Contact your dealer
or service organization.
- This message can be reset from the topside panel with any button press.
A Pump Appears to be Stuck ON
Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact
your dealer or service organization.
A Pump Appears to have been Stuck ON when spa was last powered
POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service
organization.
The water level is too low
Some systems have a water level detect, and this message appears if it detects
that the water level is too low.
Reminder Messages
General maintenance helps.
The display of Reminder Messages can be suppressed by using the PREF Menu. See
Page 12. Reminder Messages can be chosen individually by the Manufacturer.
They may be disabled entirely, or there may be a limited number of reminders
on a specific model. The frequency of each reminder (e.g. 7 days) can be
specified by the Manufacturer.
Press a Temperature button to reset a displayed reminder message.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 7 days.
Check pH with a test kit and adjust pH with the appropriate chemicals.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 7 days.
Check sanitizer level and other water chemistry with a test kit and adjust
with the appropriate chemicals.
- This message can be reset from the topside panel with any button press.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 30 days.
Clean the filter media as instructed by the manufacturer. See HOLD on page 9.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 30 days.
The Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD)
is an important safety device and must be tested on a regular basis to verify
its reliability. Every user should be trained to safely test the GFCI or RCD
associated with the hot tub installation.
A GFCI or RCD will have a TEST and RESET button on it that allows a user to
verify the proper function.
Warning:
If freezing conditions exist, a GFCI or RCD should be reset immediately or spa
damage could result. The end-user should always trained to test and reset the
GFCI or RCD on a regular basis.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 90 days.
Change the water in the spa on regular basis to maintain proper chemical
balance and sanitary conditions.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 180 days.
Vinyl covers should be cleaned and conditioned for maximum life.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 180 days.
Wood skirting and furniture should be cleaned and conditioned per the
manufacturer’s instructions for maximum life.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 365 days.
Filters should be replaced occasionally to maintain proper spa function and
sanitary conditions.
Alternates with temperature or normal display.
As needed.
Install new mineral cartridge.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 365 days.
Check your ozone and/or UV generator per your spa manufacturer’s instructions.
Alternates with temperature or normal display.
Appears on a regular schedule, e.g. every 365 days.
Have a service technician do a check-up on your spa per your spa
manufacturer’s instructions.
Warning! Qualified Technician Required for Service and Installation
Basic Installation and Configuration Guidelines
Use minimum 6AWG copper conductors only. Torque field connections between 21
and 23 in-lbs. Readily accessible disconnecting means to be provided at time
of installation. Permanently connected. Connect only to a circuit protected by
a Class A Ground Fault Circuit Interrupter (GFCI) or Residual Current Device
(RCD) mounted at least 5′ (1.52M) from the inside walls of the spa/hot tub and
in line of sight from the equipment compartment. CSA enclosure: Type 2 Refer
to Wiring Diagram inside the cover of the control enclosure. Refer to
Installation and Safety Instructions provided by the spa manufacturer.
Warning: People with infectious diseases should not use a spa or hot tub.
Warning: To avoid injury, exercise care when entering or exiting the spa
or hot tub.
Warning: Do not use a spa or hot tub immediately following strenuous
exercise
Warning: Prolonged immersion in a spa or hot tub may be injurious to your
health
Warning: Maintain water chemistry in accordance with the manufacturer’s
instructions.
Warning: The equipment and controls shall be located not less than 1.5
meters horizontally from the spa or hot tub.
Warning! GFCI or RCD Protection.
The Owner should test and reset the GFCI or RCD on a regular basis to verify
its function.
Warning! Shock Hazard! No User Serviceable Parts.
Do not attempt service of this control system. Contact your dealer or service
organization for assistance. Follow all owner’s manual power connection
instructions. Installation must be performed by a licensed electrician and all
grounding connections must be properly installed.
CSA Compliance
Caution:
- Test the ground fault circuit interrupter or residual current device before each use of the spa.
- Read the instruction manual.
- Adequate drainage must be provided if the equipment is to be installed in a pit.
- For use only within an enclosure rated CSA Enclosure 3.
- Connect only to a circuit protected by a Class A ground fault circuit interrupter or residual current device.
- To ensure continued protection against shock hazards, use only identical replacement parts when servicing.
- Install a suitably rated suction guard to match the maximum flow rate marked.
Warning :
- Water temperature in excess of 38°C may be injurious to your health.
- Disconnect the electrical power before servicing.
Warning
- Disconnect the electric power before servicing. Keep access door closed.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
42355 rev B