ADKINS Omega Series 600 Range Pneumatic Transfer User Manual
- June 9, 2024
- ADKINS
Table of Contents
- Omega Series 600 Range Pneumatic Transfer
- Introduction Omega Series 600 Press
- Installation
- How to Operate the Omega Series 600 Press
- Maintenance of the Machine
- Machine Drawings and Diagrams
- Design Change
- Guarantee (Limited Warranty)
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HEAT PRESS TECHNOLOGY
OMEGA SERIES 600
Operators Handbook
Range Pneumatic Transfer
User Manual
Omega Series 600 Range Pneumatic Transfer
All products within the ADKINS range are labelled with CE marking and are
manufactured and tested to comply with EC safety regulations.
©Charterhouse Holdings PLC. All rights reserved.
Preface
Dear User
Welcome to the growing group of Omega Series 600 Press users. The product you
have purchased has been carefully designed and manufactured to ensure that
you, the user, will gain the maximum benefit.
All Charterhouse Holdings PLC products are specifically designed to ensure
ease of use with particular attention to safety requirements.
Should you discover any fault or damage upon receipt of this product, you
should immediately contact your supplier.
Introduction Omega Series 600 Press
The Omega Series 600 Press is a pneumatically operated heat press for transfer
printing and material fusing. It is ideal for high volume production with low
operator fatigue.
The work area of the Omega Series 600 Press is 60 cm x 80 cm (23.6 in x 31.5
in) but machines may have, to special order, optional smaller sized
interchangeable worktables of any size and various shapes within this table
size.
The Omega Series 600 Press has a worktable which pulls out towards the
operating position and away from the heat plate for loading and unloading.
After loading the work piece, and with the correct settings for temperature,
pressure and dwell time, the worktable is pushed back to the operating
position with the handle provided. The cycle is started by pressing the green
buttons on either the side of the head. The controller operates the timer and
the solenoid valve and thus the pneumatic cylinder. When the set time elapses
the heat plate is automatically lifted, enabling the worktable to be pulled
out. The worktable may then be unloaded and reloaded ready for another cycle.
The Omega Series 600 Press is produced in one version, nominally 230 Volts AC
for the European market.
1.1 What did you receive?
The Omega Series 600 Press has been a placed in a shipping crate, and is held
in place with bolts, for safe transportation. The following articles should
have been delivered:
- Omega Series 600 Press
- Omega Series 600 Press Operators Handbook
- Any extra items ordered
If there is any damage or any article is missing, please contact your
supplier immediately.
1.2 Specifications of the Omega Series 600 Press
The Omega Series 600 Press is a pneumatically operated heat press for
transfer printing and material fusing. It is ideal for high volume production
with low operator fatigue.
Specification
Power consumption | 4.5 kW |
---|---|
Power supply | 230 Volts AC (Single Phase) |
Working temperature | 70 – 225° C (32 – 437°F) |
Display timer range | 0 – 999 sec (±0.5%) |
Machine height | 100 cm (39 in) |
Machine width | 80 cm (31.5 in) |
Machine depth, closed | 123 cm (48.5 in) |
Machine depth, open | 152 cm (59.8 in) |
Size export packed | 137(L) x 121(W) x 122(H) cm (60(L) x 47.5(W) x 48(H) in) |
Working area required | 81(W) x 100(H) x 194(D) cm (32(W) x 39(H) x 76(D) in) |
Net weight | 183 kg (403.4 lbs.) |
Gross weight | 304 kg (670 lbs.) |
Press pad dimensions | 60 cm x 80 cm (23.6 in x 31.5 in) |
Maximum compressed air supply | 6 bar (87 Psi) |
Compressed air consumption | 5 – 40 litres/min (0.17 – 1.41 cu. ft./min) |
A-weighted noise level | <70dB(A) |
Amps | 63 Amp trip |
Fuse | 27 A |
1.3 Safety
The Omega Series 600 Press has been equipped with various safety features
to ensure operator safety.
a. The time/temperature controller has a built in facility giving error
messages in the event of faults with the element heating and control system.
b. Emergency stop button.
c. The machine table will only set to pressing position when the heat
plate is aligned with it due to a micro switch safety interlock.
1.4 Safety Tips
If required, our customer service team can arrange maintenance service.
-
The Omega Series 600 Press meets the European Legislation standard. Under normal conditions accidents are rare. However, listed below are some practical points to ensure your safety.
-
Always switch off and isolate the mains supply (i.e. Remove plug) before undertaking any maintenance work or cleaning the machine, or when it is not in use.
-
Keep other people away from the machine during use.
-
Ensure that there is sufficient space around the machine.
Cables and connections must not get jammed. Although the heat radiation of the press is low, there should be enough space for cooling down. -
Avoid contact with the press element.
-
DO NOT REMOVE THE TOP COVER UNLESS QUALIFIED TO DO SO – touching internal parts is dangerous and may cause shock hazard.
-
PROTECT THE MAINS CABLE – damage to the mains cable may cause fire or shock hazard. When unplugging, hold by the plug only and remove carefully. Take care that the mains cable does not come into contact with the heat plate (or moving parts of the mechanism) during operation of the machine.
-
FOR SAFETY REASONS – please ensure that when the machine is not in use the table is fully closed.
-
OPERATING AMBIENT TEMPERATURE RANGE – the operating ambient temperature range is 0ºC – 35ºC, (32 F – 104ºF) and humidity of 20 – 80%.
-
MACHINE FUSES – type: ultra-rapid (FF) fuse 1¼”. (220 Vac Max. 63 Amps)
-
WARNING – THIS APPARATUS MUST BE EARTHED (GROUNDED).
-
CAUTION
This machine gets hot whilst operating. Take care not to touch any surfaces that are labelled “Caution this plate is HOT”. -
MACHINE OPERATION
Only suitably trained personnel should operate this machine.
This machine is designed to be operated by one operator only. -
CAUTION
Please ensure the table is fully engaged before pressing the green cycle start buttons.
For operator safety this machine is fitted with a non-return valve that prevents the table from lowering if the air supply is lost.
Contact your print media suppliers to ascertain whether fumes are given off during the process, and if so what precautions are needed for operator safety. These may include air extraction and/or masks for personnel.
Please refer to section 5.1 for an illustration of the Omega Series 600 Press.
Installation
2.1 Transport instructions
The machine comes to you, in a shipping crate, and is held in place with
bolts, for safe transportation. If you have to transport the machine at any
time it is recommended that you use a similar box and packing method. Please
let the machine cool down fully before attempting to pack.
2.2 Installing the machine
Take the machine out of the crate, due to the weight of the machine we
recommend that a fork lift truck or winch is used. Put the machine on a sturdy
worktable close to a suitable electric socket and compressed air supply
connection point, within easy reach of the operator. There must be sufficient
space for the machine’s table to be pulled out until it hits the built in
stops and back to the pressing position without creating trapping points
against adjacent articles. Ensure that no items vulnerable to heat radiation
are too close to the machine.
2.3 Electrical requirements
The Omega Series 600 Press should be connected to the mains supply
(nominally 230 Volts AC for the European Market) using either a commando plug
and socket or an isolator box.
The press is designed for 230 Volts AC 50/60 hertz and requires exclusive use
of a power outlet rated for at least 32 amps.
Ensure that the supply rating on the machine specification plate corresponds
with your local supply and that the correct plug is fitted.
MAINS LEAD
The wires in this mains lead are coloured in accordance with the following
code:
Wiring the plug for a 230 VAC machine.
As the colours of the wires in the mains lead of this apparatus may not
correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:-
- The wire, which is, coloured green and yellow must be connected to the terminal in the plug, which is marked by the letter E, or by the safety earth symbol coloured green, or green and yellow.
- The wire coloured blue must be connected to the terminal, which is marked with the letter N, (Neutral connector)
- The wire coloured brown must be connected to the terminal, which is marked with the letter L, (Live connector)
NOTE: Replacement of the mains cable must be undertaken by a competent
service engineer.
2.4 Pneumatic requirements
The Omega Series 600 Press should be connected through a filter regulator
to a compressed air supply capable of delivering 40 litres/min at a pressure
of 1 – 5 bar. max. (1.06 cu.ft./min at 14.5 – 72.5 psi).
The press will not operate if the pressure drops below 1 bar. (14.5 psi.)
Double hose clips should be used on the delivery hose.
We would advise that when setting up the machine you check that sufficient
pressure is maintained into the regulator valve. When the desired pressure is
achieved the regulator is locked by pushing the knob back down. We recommend
that this should be set between 3.5 to 5 Bar.
The Pressure Adjustment Gauge on the left hand side of the machine should only
be used to control the settings required for heat transfer and garments.
2.5 Adjusting the pressure
This press is fitted with a manually adjustable pneumatic pressure
regulator on the left hand side of the machine. To adjust the operating air
pressure, and therefore the pressure exerted by the press on the work, the
regulator is unlocked by pulling upwards on the black plastic knob. Turning
the regulator knob clockwise will increase the air pressure; turning
anticlockwise will decrease the pressure. When the desired pressure is
achieved the regulator is locked by pushing the knob back down.
How to Operate the Omega Series 600 Press
3.1 Starting with the Omega Series 600 Press
3.1.1 Turn on the Omega Series 600 Press; the on/off switch is on the
front of the machine head. Set the machine controls as necessary. See
instructions for adjusting the pressure, section 2.5, and the operation of the
time temperature unit, section 5.2. When the set temperature is steady in the
display the machine is ready to use.
3.2 Working with Heat Transfer Materials
3.2.1 Ascertain from the supplier of the transfer paper and/or the suppliers
of the material, that the material to be used is suitable and has been
prepared for transfer printing.
3.2.2 Obtain from the supplier of the transfer paper, or material to be
used, the recommended temperature, time and pressure settings for the material
to be worked on.
Approximate settings are usually within the following:-
180ºC – 200ºC (350ºF – 400ºF) | Heat Setting |
---|---|
10 – 30 sec | Time Dwell Setting |
3.2.3 Wait until the set temperature has been reached, signalled by the
temperature on the controller display becoming steady at the desired figure.
Pull the table assembly from beneath the heat plate using the handle on the
front of the machine. Place the work piece on the pressure pad, removing all
wrinkles. Place the transfer in the desired position. Push the table assembly
back into the pressing position, until it stops. This will ‘trigger’ the micro
switch which will enable the machine to perform a heat transfer cycle.
3.2.4 Start the sequence by pressing the green buttons located on either
side of the machine head. The heat plate will automatically lower to the
table. (The process can be stopped at any time by using the “EMERGENCY STOP”
button on the front of the machine head. This will automatically raise the
heat plate away from the table).
CAUTION
Please ensure the table is fully engaged before pressing the green cycle start
buttons.
3.2.5 At the end of the set time, the heat plate rises, allowing the
table to be pulled out to permit unloading.
3.3 Pressing Pad Assembly
The pressing pad supplied with this machine is made of heat proof
foam/green silicone and has a Nomex® cover and although they are extremely
durable they must be maintained in good condition at all times and replaced
when showing signs of wear. A worn pressing pad will always affect the quality
of printing/fusing.
CAUTION: Do not insert items into the machine, which would tend to cut
the pressing pad, i.e. buttons, pins, press-studs or zips.
IMPORTANT NOTE:
The pressing pad supplied with the machine is of the correct thickness.
Using a thicker pad may invalidate your warranty.
3.4 Shutting Down
To shut down the machine when a cycle is finished, turn off the red
illuminated rocker switch on the front of the machine head.
To temporarily interrupt the pressing cycle, press the red button on the
front of the machine head.
3.5 Fault Diagnosis
This Omega Series 600 Press has built in fault diagnosis. The display may
show the following:
-
Probe Fault
If the probe goes open circuit, the display will show “Probe Fault” immediately. Contact your machine supplier immediately. -
“CAL” Fault
If “CAL” appears in the controller display the controller will need to be recalibrated. Switch off the machine and contact your supplier for an instruction sheet.
CAUTION
In all fault conditions switch off the power to the machine and unplug the machine from the electrical supply before contacting your machine supplier.
3.6 Hints and Tips
Transfer Printing
Extra care should always be taken to ensure that transfer paper is placed
print down onto the article, as mistakes will result in the heat plate
becoming soiled with ink and spoiling following work.
When transfer printing, it may be found advantageous to cover the press
pad with paper or P.T.F.E. to prevent strike-through of surplus ink,
particularly when printing thin material as surplus print on the pressing pad
cover can also strike back on the following work.
Transfer Paper/Motifs Fail to Print Out Correctly
Check:-
- Heat and time dwell settings are correct.
- Article having transfers applied is locked in contact between pressing pad and heat plate.
- Pressing pad is in good condition, is flat and making complete contact over the whole area of the heat plate. See Pressing Pad details.
“Ghosting” (Double Image) of Transfer Prints
Check:-
- Material being used has been correctly heat set for transfer printing.
- Material being used does not shrink during printing process, i.e. measure material before and after printing.
- Transfer paper does not move after printing process upon lift off of the heat plate.
- If possible, use adhesive coated paper, particularly to overcome fabric shrinkage.
- By pre-shrinking of material in press before transfer printing.
Maintenance of the Machine
4.1 Daily Maintenance
For good press results it is important to keep the press surfaces clean.
Wipe the surface of the heat plate with a dry non-abrasive cloth before use
when the plate is cold.
When heat plates are hot and not in use, keep in the open position away from
the foam pad.
4.2 Periodic Maintenance
Periodically clean the Teflon® coated heat plate with a non-abrasive piece
of cloth. Stubborn stains may be cleaned, when heat plate is cool, with
mineral spirits.
4.3 Cleaning
First unplug the machine. Clean the outside of the machine frequently with
a clean, moist cloth. This may conveniently be carried out when the machine is
cold.
To prevent soiling of the substrate, periodic wiping of the entire exterior of
the machine, including heat plate, with a clean rag is recommended.
If necessary, use mineral spirits for cleaning a cold machine. Since mineral
spirits are flammable, use precautions at all times and keep away from sparks,
flames or hot heat plate.
Machine Drawings and Diagrams
On the following pages are the schematic diagrams for the Omega Series 600
Press.
5.1 General Layout
5.2 Operation Of Control Unit, Setting Time and Temperature
(The Heat Plate must always be in the down position before the Controller is
set)
Setting Temperature
- Switch on machine.
- Press the ‘OK’ button to enter the temperature setting mode (the ‘ºC’ light will flash).”
- Using the ‘ ▼ ‘ or ‘ ▲ ‘ buttons select between ‘ºC’ or ‘ºF’.
- Press the ‘OK’ button twice to enter the temperature setting mode (the temperature settings digits and ‘SV’ will flash).
- Use the ‘ ▼ ‘ or ‘ ▲ ‘ buttons to select the temperature required for the transfer material being used.
- Press the ‘OK’ button to turn the ‘SV’ light and temperature settings digits off.
Setting Time
- Press the ‘OK’ button three times to enter the time setting mode (the ‘SV’ and time settings lights will flash).
- Use the ‘ ▼ ‘ or ‘ ▲ ‘ buttons to select the time required for the transfer material being used.
- Press the ‘OK’ button to turn the ‘SV’ and time settings lights off.
- The digital display will now show the rising temperature until the set heat is achieved. At this point a buzzer will sound to indicate that the machine has reached the set operating temperature and is ready to use.
- To reset the timer to zero press and hold ‘Reset’ button for 5 seconds.
5.3 Exploded Diagram and Parts List
No. | Part Description | Qu. | Part No. |
---|---|---|---|
1 | Machine foot | 4 | OMC750/24 |
2 | Magnet | 1 | OMC750/39 |
3 | Micro switch | 1 | OMC750/36 |
4 | Bearing (LM25UU-OP) | 4 | OMC750/38 |
5 | Start-up button | 2 | OMC750/9 |
6 | Linear bearing | 2 | OMC750/11 |
7 | Plug connector | 1 | OMC750/2 |
8 | Power cord | 1 | OMC750/1 |
9 | Fuse 6 amps | 1 | OMC750/40 |
10 | Fuse holder | 1 | OMC750/468 |
11 | Circuit breaker | 1 | OMC750/41 |
12 | 3/4” Coiler joint | 1 | OMC750/42 |
13 | Ø12mm Air pipe (5 m) | 1 | OMC750/43 |
14 | Filter regulator/ Pressure gauge | 1 | OMC750/27 |
15 | Glide rail filler strip | 2 | OMC750/44 |
16 | Glide rail | 2 | OMC750/26 |
17 | Crashproof spacer | 2 | OMC750/45 |
18 | Draw handle | 1 | OMC750/20 |
19 | Straight line handle | 4 | OMC750/46 |
20 | C-tape quick coupling | 1 | OMC750/47 |
21 | Table | 1 | OMC600/22 |
22 | Foam pad (60 x 80 cm) | 1 | OMC600/23 |
23 | Heat plate | 1 | OMC600/19 |
24 | Heat plate cover | 1 | OMC600/18 |
25 | Wire slot | 1 | OMC600/48 |
26 | Heat resistant gasket | 4 | ASCL32 |
27 | Spring | 6 | OMC750/15 |
28 | M16 Bolt | 6 | OMC750/50 |
29 | Cap nut | 6 | OMC750/12 |
30 | Adapter plate | 1 | OMC750/17 |
31 | M16x35 Bolt | 6 | OMC750/31 |
32 | M16 Spring washer | 6 | OMC750/51 |
33 | M16 Gasket | 10 | OMC750/52 |
34 | Cylinder guide rod | 2 | OMC750/53 |
35 | Air cylinder | 1 | OMC750/6 |
36 | Cylinder spacer | 1 | OMC750/54 |
37 | Metal conduit cable | 1 | OMC750/32 |
38 | Emergency stop button | 1 | OMC750/10 |
39 | Digital controller | 1 | OMC750/35 |
40 | Power switch | 1 | OMC750/7 |
41 | Solid state relay | 1 | OMC750/30 |
42 | Transformer | 1 | OMC750/29/06 |
43 | Relay and base 12V | 1 | OMC750/37 |
44 | Electromagnetic valve | 1 | OMC750/25 |
45 | Fan protective cover | 2 | OMC750/55 |
46 | Fan | 2 | OMC750/56 |
47 | Non return valve | 1 | FP3142/U |
48 | Straight connector 12 mm | 2 | FP3042/U |
49 | Ring probe | 1 | FP3057/2M |
5.4 Electrical Diagram
KEY:
K0: Air switch (Main power switch)
FU1-FU2: Fuse
K1: Second power switch
K5: Limit switch
K2 (K3): Start switch
K6: Thermostat switch
R1: Solid-state relay (TSR-100A)
EH1-EH2: Heat platen
A-B: Thermocouple
SJ: Digital controller
MD: Transformer
P1 (K4): Emergency stop button
J: Intermediate relay coil
D: Pneumatic solenoid valve
L1/L2: Start switch indicator light
FAN1: 2 PCS Fan
5.5 Pneumatic Schematic![ADKINS Omega Series 600 Range Pneumatic Transfer
- Pneumatic Schematic](https://manuals.plus/wp-content/uploads/2023/03/ADKINS- Omega-Series-600-Range-Pneumatic-Transfer-Pneumatic-Schematic.jpg)
Design Change
With the policy of constant improvement and/or modification to meet changing conditions, the right is reserved to change the design and/or specifications at any time without prior notification, and therefore specifications may vary and not be in accordance with this manual.
Guarantee (Limited Warranty)
Charterhouse Holdings PLC warrants that the press is free from defects in
material and workmanship for a period of 12 months from the date of supply.
The machine comes with a 12 month warranty on the heating element, 12 month
warranty on parts and 90 days labour.
This guarantee will only be effective when Charterhouse Holdings PLC
authorizes the original purchaser to return the machine to the factory, and
only when the product upon examination has proven to be defective.
Should in our opinion any part of this press be defective in materials or
workmanship, it will be replaced or repaired free of charge, provided that the
press has been installed and operated in the correct manner and not subjected
to misuse. (This is excluding any travelling and/or carriage costs which will
be charged at our discretion.)
This guarantee does not apply to any machine that has been subjected to
misuse, negligence, alteration or accident.
A charge will be made for any costs incurred if a reported fault on the
press is found to be due to incorrect installation, operation and/or incorrect
materials being used. It is the responsibility of the press user to ensure the
suitability of the materials operating through the press.
In order for this guarantee to be effective, no return of machine or
parts may be made without prior factory authorization.
No claim of any kind shall be greater in amount than the sale price of
the product or part to which the claim is made.
This is the sole guarantee given by the company, it is in lieu of any
other guarantees, expressed or implied, in law or in fact, including the
guarantees of merchantability and fitness for particular use, and is accepted
as such by the purchaser in taking delivery of this product.
Charterhouse Holdings PLC shall not be liable for any injury, loss or
damage, direct or consequential, arising out of the use or the inability to
use the product.
A. ADKINS & SONS LIMITED
DECLARATION OF CONFORMITY
Application of Council Directives:
Standards to which Conformity is Declared:
Manufacturer’s Name:
Manufacturer’s Address:
Type of Equipment:
Standards Compliance:
Model Number:
Serial Number:
Year of Manufacture:
Machinery, Low Voltage. E.M.C.
BS EN ISO 12100:2010 – Safety of machinery: Basic Technology, Principles
of Design.
BS EN 60204-1:2006+A1:2009 – Safety of machinery: Electrical Equipment of
Machines.
BS EN 60529:1992-A2:2013 – Degree of protection provided by enclosures.
BS EN ISO 13850:2015 – Safety of Machinery: Emergency Stops.
BS EN ISO 141211:2007 – Safety of Machinery: Principles for Risk
Assessment.
BS EN 55011:2016+A1:2017 – Class A Group 2 Equipment – EMC Emissions.
BS EN ISO 61000-6-4:2007+A1:2011 – EMC Conducted Emissions.
BS EN ISO 61000-6-2:2005 – EMC Immunity.
Low Voltage Directive 2014/35/EC – Including DIN EN 61557-1, -4 and -5.
Electro Magnetic Interference Directive 2014/30/EC – Including DIN EN
61000-6 series of standards.
A. Adkins & Sons Limited
High Cross, 18 Lancaster Road,
Hinckley, Leicester, LE10 0AW, United Kingdom.
Omega Series 600 Heat Press
I, the undersigned, hereby declare that the equipment specified above conforms
to the above directives and standards.
Place: Hinckley, United Kingdom
Date: …………..
Signature:
Full Name: Marie McMahon
Position: General Manager
Read User Manual Online (PDF format)