BALBOA TP500 Control Panels User Guide
- June 1, 2024
- BALBOA
Table of Contents
TP500 Control Panels
User Guide for Standard Menu TP500
TP500 Control Panels
System Model: | All BP series systems |
---|---|
Panel Model: | TP500 |
Panel Software Version: | All versions |
Display Icons
A – Heat
B – Ready Mode
C – Rest Mode
D – bba™2 On
E – WiFi (Cloud Connection)| F – Light
G – Cleanup Cycle
H – Jets 1
I – Jets 2
J – Blower| K – Auxiliary (Jets 3 or )
L – Temperature Range (High / Low)
M – Set (Programming)
N – Filter Cycle (1 or 2 or Both)
O – AM or PM (Time)
---|---|---
MicroSilk® is a registered trademark of Jason International.
Main Menus
Navigation
Navigating the entire menu structure is done with 2 or 3 buttons on the
control panel.
Some panels
have separate WARM (Up) and COOL (Down) buttons, while others have a single
Temperature button. In the navigation diagrams Temperature buttons are
indicated by a single button icon.
Panels that have two Temperature buttons (Warm and Cool) can use both of them
to simplify navigation and programming where a single Temperature icon is
shown.
The MENU/SELECT Button is used to choose the various menus and navigate each
section.
Typical use of the Temperature button(s) allows changing the Set Temperature
while the numbers are flashing in the LCD. the menus can be exited with certain
button presses. Simply waiting for a few seconds will return the panel
operation to normal.
Power-up Screens
Each time the System powers up, a series of numbers is displayed.
After the startup sequence of numbers, the system will enter Priming Mode (See
Page 3).
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
Waiting a few seconds in the Main Menu will allow the display to
revert to the Main Screen.
Most changes are not saved unless Menu/Select is pressed.
Refer to key above.
Spa Behavior
Pumps
Press the “Jets” button once to turn pump 1 on or off, and to shift between
low and high speeds if equipped. If left running, the pump will turn off after
a time-out period. On non-circ systems, the low-speed of pump 1 runs when the
blower or any other pump is on. If the spa is in Ready Mode (See page 6), Pump
1 low may also activate once in a while for at least 1 minute to detect the
spa temperature (polling) and then to heat to the set temperature if needed.
When the low-speed turns on automatically, it cannot be deactivated from the
panel, however the high speed may be started.
Circulation Pump Modes
If the system is equipped with a circ pump, it will be configured to work in
one of three different ways: 1, The circ pump operates continuously (24 hours)
with the exception of turning off for 30 minutes at a time when the water
temperature reaches 3°F (1.5°C) above the set temperature (most likely to
happen in very hot climates). 2, The circ pump stays on continuously,
regardless of water temperature. 3, A programmable circ pump will come on when
the system is checking temperature (polling), during filter cycles, during
freeze conditions, or when another pump or blower is on. The specific
Circulation Mode that is used has been determined by the Manufacturer and
cannot be changed in the field.
Temperature and Temp Range
Adjusting the Set Temperature
When using a panel with Up and Down buttons (Temperature buttons), pressing Up
or Down will cause the temperature to flash. Pressing a temperature button
again will adjust the set temperature in the direction indicated on the
button. When the LCD stops flashing, the spa will heat to the new set
temperature when required.
If the panel has a single temperature button, pressing the button will cause
the temperature to flash. Pressing the button again will cause the temperature
to change in one direction (e.g. UP). After allowing the display to stop
flashing, pressing the Temperature Button will cause the temperature to flash
and the next press will change the temperature in the opposite direction (e.g.
DOWN).
Press-and-Hold
If a Temperature button is pressed and held when the temperature is
flashing, the temperature will continue to change until the button is released.
If only one temperature button is available and the limit of the Temperature
Range is reached when the button is being held, the progression will reverse
direction.
Dual Temperature Ranges
This system incorporates two temperature range settings with independent set
temperatures. The High Range designated in the display by a thermometer and an
“up” arrow, and the Low Range designated in the display by a thermometer and
“down” arrow.
These ranges can be used for various reasons, with a common use being a “ready
to use” setting vs. a “vacation” setting.
The Ranges are chosen using the menu structure below. Each range maintains its
own set temperature as programmed by the user. This way, when a range is
chosen, the spa will heat to the set temperature associated with that range.
For example:
High Range might be set between 80°F and 104°F.
Low Range might be set between 50°F and 99°F.
More specific Temp Ranges may be determined by the Manufacturer.
Freeze Protection is active in either range.
See Ready and Rest on Page 6 for additional heating control information.
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
Mode – Ready and Rest
In order for the spa to heat, a pump needs to circulate water through the
heater. The pump that performs this function is known as the “primary pump.”
The primary pump can be either a 2-Speed Pump 1 or a circulation pump.
If the primary pump is a 2-Speed Pump 1, Ready Mode (indicated by R ) will
circulate water periodically, using Pump 1 Low, in order to maintain a
constant water temperature, heat as needed, and refresh the temperature
display. This is known as “polling.”
Rest Mode (indicated by ) will only allow heating during programmed filter
cycles. Since polling does not occur, the temperature display may not show a
current temperature until the primary pump has been running for a minute or
two.
Circulation Mode (See Page 4, under Pumps, for other circulation modes)
If the spa is configured for 24HR circulation, the primary pump generally runs
continuously. Since the primary pump is always running, the spa will maintain
set temperature and heat as needed in Ready Mode, without polling.
In Rest Mode, the spa will only heat to set temperature during programmed
filter times, even though the water is being filtered constantly when in
Circulation Mode.
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.Ready Mode will allow the spa to Poll
and determine a need for heat. The panel will maintain a “current” temperature
display.
Toggle between Ready (indicated by ) and Rest (indicated by ).
Pressing Menu/Select when the display is toggled will go to Main
Screen.The Main Screen
will display RUN PUMP FOR TEMP if the primary pump has not run for over 1
hour.
The Main Screen will display normally during Filter Cycles or when the spa is
in use.
If the primary pump has been off for an hour or more, when any function
button, EXCEPT Light, is pressed on the panel, the pump used in conjuncton
with the heater will run so that temperature can be sensed and displayed.
Ready-in-Rest Mode
R appears in the display if the spa is in Rest Mode and “Jets” is pressed. It is assumed that the spa is being used and will heat to set temperature. The primary pump will run until set temperature is reached, or 1 hour has passed. After 1 hour, the System will revert to Rest Mode. This mode can also be reset by entering the Mode Menu and changing the Mode.
Show and Set Time-of-Day
Be sure to set the Time-of-Day
Setting the time-of-day can be important for determining filtration times and
other background features.
When in the TIME menu, SET TIME will flash on the display if no time-of-day is
set in the memory.
24-hour time display can be set under the PREF menu. (See Page 12)
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item. Note:
This note refers to systems that do not keep track of Time-of-Day when powered
down.
If power is interrupted to such a system, Time-of-Day is not stored. The
system will still operate and all other user settings will be stored. If filter
cycles are required to run at a particular time of day, resetting the clock
will return the filter times to the actual programmed periods.
When such a system starts up, it defaults to 12:00 Noon, so another way to get
filter times back to normal is to start up the spa at noon on any given day.
SET TIME will still flash in the TIME Menu until the time is actually set, but
since the spa started at noon, the filter cycles will run as programmed.
Flip (Invert Display)
Toggle the inversion of the segmented characters Pressing Menu/Select when the display is toggled will go to Main Screen.
Adjusting Filtration
Main Filtration
Filter cycles are set using a start time and a duration. Start time is
indicated by an “A” or “P” in the bottom right corner of the display. Duration
has no “A” or “P” indication. Each setting can be adjusted in 15-minute
increments. The panel calculates the end time and displays it automatically.
Key
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message – every 1/2 second
A temperature button, used for “Action”
Menu/Select button
Waiting time that keeps the last change to a menu item.
Waiting time (depends on menu item) that reverts to original setting and
ignores any change to that menu item.
Filter Cycle 2 – Optional Filtration
Filter Cycle 2 is OFF by default.
It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will
shorten overall filtration by the overlap amount.
Purge Cycles
In order to maintain sanitary conditions, secondary Pumps and/ or a Blower
will purge water from their respective plumbing by running briefly at the
beginning of each filter cycle.
If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a
purge when Filter Cycle 2 is programmed to begin.
General Messages
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be
displayed.
Too Cold –
Freeze Protection
A potential freeze condition has been detected, or the Aux Freeze Switch
has closed, and all pumps and blower are activated, either one at a time, or
all at once, depending on how your system was built. All pumps and blower are
ON for at least 4 minutes after the potential freeze condition has ended, or
when the aux freeze switch opens.
In some cases, pumps may turn on and off and the heater may operate during
Freeze Protection.
This is an operational message, not an error indication.
Water is too
Hot (OHS) – MO29
One of the water temp sensors has detected spa water temp 110°F (43.3°C) and
spa functions are disabled. System will auto reset when the spa water temp is
below 108°F (42.2°C). Check for extended pump operation or high ambient temp.
Manufactured under one or more of these patents.
U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227,
62823706590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both
foreign andomestic applied for and pending.
All material copyright of Balboa Water Group.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>