Features

  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit/Overload/ver voltage/
  • Over Temperature
  • Forced air cooling by built-in DC fan
  • Built-in cooling Fan ON-OFF control
  • 1U low profile
  • Withstand the 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • High operating temperature up to 70’C
  • Operating altitude up to 5000 meters (Note.8)
  • High efficiency, long life, and high reliability
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, pieces of equipment, or apparatus

GTIN Code

Description

LRS-350 series is a 350W single-output enclosed type power supply with 30mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 3.3V, 4.2V,5V, 12V, 15V, 24V, 36V, and 48V. In addition to the high efficiency of up to 89%, with the built-in long-life fan LRS-350 can work under -25 +70’C with a full load. Delivering an extremely low no-load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-350 has complete protection functions and 5G anti-vibration capability: it complies with international safety regulations such as IEC/UL 62368-1. LRS-350 series serves as a high-price-to-performance power supply solution for various industrial applications.

Model Encoding

SPECIFICATION

MODEL| LRS-350-3.3| LRS-350-4.2| LRS-350-5| LRS-350-12| LRS-350-15| LRS-350-24| LRS -350-36| LRS-350-48
---|---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 4.2V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 60A| 60A| 60A| 29A| 23.2A| 14.6A| 9.7A| 7.3A
CURRENT RANGE| 0 ~ 60A| 0 ~ 60A| 0 ~ 60A| 0 ~ 29A| 0 ~ 23.2A| 0 ~ 14.6A| 0 ~ 9.7A| 0 ~ 7.3A
RATED POWER| 198W| 252W| 300W| 348W| 348W| 350.4W| 349.2W| 350.4W
RIPPLE & NOISE (max.) Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.97 ~ 3.6V| 3.6 ~ 4.4V| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±4.0%| ±4.0%| ±3.0%| ±1.5%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.5%| ±2.5%| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1300ms, 50ms/230VAC       1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms/230VAC     12ms/115VAC at full load

INPUT

| VOLTAGE RANGE| 90 ~ 132VAC / 180 ~ 264VAC by switch        240 ~ 370VDC  (switch on 230VAC)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 79.5%| 81.5%| 83.5%| 85%| 86%| 88%| 88.5%| 89%
AC CURRENT (Typ.)| 6.8A/115VAC         3.4A/230VAC
INRUSH CURRENT (Typ.)| 60A/115VAC        60A/230VAC
LEAKAGE CURRENT| <2mA / 240VAC

PROTECTION

|

OVER LOAD

| 110 ~ 140% rated output power
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.

OVER VOLTAGE

| 3.8 ~ 4.45V| 4.6 ~ 5.4V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18 ~ 21V| 28.8 ~ 33.6V| 41.4 ~ 46.8V| 55.2 ~ 64.8V
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
OVER TEMPERATURE| 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
FUNCTION| FAN ON/OFF CONTROL

(Typ.)

| RTH3≧50℃ FAN ON, ≦40℃ FAN OFF

ENVIRONMENT

| WORKING TEMP.| -25 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY

| SAFETY STANDARDS| IEC/UL 62368-1, BSMI CNS14336-1,EAC TP TC 004,KC K60950-1(for LRS-350-12/24 only),

BIS IS13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS62368.1 approved; Design refer to BS EN/EN62368-1

WITHSTAND VOLTAGE| I/P-O/P:3KVAC  I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN55035, EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only)

OTHERS

| MTBF| 2099.9K hrs min.     Telcordia SR-332 (Bellcore) ;  328.6Khrs min.     MIL-HDBK-217F (25℃)
DIMENSION| 21511530mm (LWH)
PACKING| 0.76Kg; 15pcs/12.4Kg/0.78CUFT
NOTE

| 1. All parameters NOI specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Hipple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with an O.1uf & 47ut parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation, and load regulation.
4. Line regulation is measured from the low line to the high line at the rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ONOFF the power supply very quickly may lead to increase of the set up time.
7. The 150% peak load capability is built in for up to 1 second for 12-48V.LRS-350 will enter hiccup mode if the peak load is delivered
for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).
8. The ambient temperature derating of 5 C/1000m is needed for operating altitude greater than 2000m(6500ft).
9. This power supply does not meet the harmonic current requirements outined by BS EN/EN61000-3-2. Please do not use this power supply
under the following conditions:
a) the end-devices is used within the European Union, and
b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
)the power supply iS:
installed in end-devices with average or continuous input power greater than 75W, or
belong to part of a lighting system rom Arrow.c
EXception:
Power supplies used within the following end-devices do not need to fufill BS EN/EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W;
b) symmetrically controlled heating elements with a rated power less than or equal to 200w
X Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
 |  |  |

Block Diagram

MEAN-WELL-lrs-350-350W-Single-Outpu-
FIG-1

Derating Curve

MEAN-WELL-lrs-350-350W-Single-Outpu-
FIG-2

Mechanical Specification

MEAN-WELL-lrs-350-350W-Single-Outpu-
FIG-3

Installation Manual

Please refer to:http://www.meanwell.com/manual.html

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals