Measuring blood pressure

Positioning the Cuff:

BM67 - Measuring blood pressure 1

• Place the cuff round your bare left upper arm 0.8 in to 1.2 in (2 to 3 cm) above the bend of the elbow and above the artery, with the tube in line with the center of the palm. Ensure blood circulation is not be restricted by tight clothing or other objects.

BM67 - Measuring blood pressure 2

• Fasten the cuff, making sure it is not too tight around your arm.

BM67 - Measuring blood pressure 3

• You should be able to fit two fingers under the cuff after it is in place.

BM67 - Measuring blood pressure 4

• Insert the Air Tube Connector into the Air Tube Port.

Performing the blood pressure measurement

BM67 - Performing the blood pressure measurement1) Insert four AAA alkaline batteries into the battery compartment as indicated. Set the date and time as instructed in the user manual.
2) To select a user memory, press the SET button and select a user from 1 to 4 using the +/- buttons. Confirm your selection by pressing the button or wait for three seconds.
3) Attach the cuff to your arm as described on the left and connect the air tube to the main unit. Sit up straight and rest your arm on a table or countertop.
4) Press the button to begin. Press the button again at any time to cancel.
5) The measurement data will be stored automatically into the selected user memory. Press the button to shut off the blood pressure monitor.

Transfer via Bluetooth®

Measured values can also be transferred to your smartphone via Bluetooth®. You will need the ‘beurer HealthCoach‘ app for this, which is available free of charge from the app store of your smartphone.
To use the Bluetooth® function proceed as follows:

  1. Activate Bluetooth® on your smartphone.
  2. Activate Bluetooth® on your Blood Pressure Monitor using SET and +/-.
  3. Download the ‘beurer HealthCoach‘ app from Apple App Store or Google Play.
  4. Start the app and follow the instructions. Select BM67 in the app.
  5. Carry out the blood pressure measurement; the data transfer takes place automatically following the user selection.

works with

HEALTH COACH logo x1

APP Store Icon     google play icon

QR Code - beurer HealthCoach app

List of supported devices

System requirements
– iOS ≥ 8.0 / Android™ ≥ 4.4
– Bluetooth® 4.0

Read all instructions for use before use

How to use your new blood pressure monitor correctly to ensure accuracy:

Before taking your blood pressure measurement:

  Rest at least 5 min before taking the measurement.  BM67 - Use
1

  Avoid eating, smoking or any form of exertion before a measurement.  ![BM67

  Remove any garment that fits closely or tightly to wrist.  BM67 - Use
3

  Do not flex muscles in the measurement arm during measurement.  BM67 - Use
4

  To obtain comparable values, always measure your blood pressure at the same time of day.  BM67 - Use 5

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Beurer North America is under license. Other trademarks and trade names are those of their respective owners.

Did you know?
A properly fitting cuff, correctly positioned on the arm, is essential to ensure accurate blood pressure measurements

Frequently asked questions:

Q: How do you know if your blood pressure monitor is accurate?
A: The technology used in your new blood pressure monitor meets the highest clinical standards. When used correctly, this monitor will provide readings comparable to those taken in your doctor’s office. Always wait at least 5 minutes between measurements.
Note: Due to normal physiologic changes and many external factors influencing blood pressure, it is unusual to obtain identical measurements even when taken a few minutes apart.

Q: Why might your blood pressure results be different than at your doctor’s office?
A: Many people experience what is called “White Coat Hypertension” when having blood pressure measured in a doctor’s office or clinic. The blood pressure readings are somewhat higher than the readings you obtain when you measure it yourself in a relaxed atmosphere at home.
People who have raised blood pressure under the stress of everyday conditions can have normal readings under quiet conditions at the doctors. Then, we speak of “doctor’s surgery normotension”. Discuss the possibility of White Coat Hypertension with your doctor.

Q: Your blood pressure varies throughout the day. How do you know which is your true blood pressure?
A: The average of several results obtained over several days, under comparable conditions represents your individual blood pressure.
In order to ensure comparable values, always measure your blood pressure at the same time of the day.

Risk Category Indicator:

The Risk Category Indicator uses a bar on the display to show your blood pressure as Optimal, Normal, High normal, Setting 1 (mild hypertension), Setting 2 (moderate hypertension) or Setting 3 (severe hypertension).

Stages of blood pressure levels| Systolic (mmHg)| Diastole (mmHg)| Color
---|---|---|---
Setting 3:
severe hypertension| ≥ 180| ≥ 110| seek medical attention
Setting 2:
moderate hypertension| 160 – 179| 100 – 109| seek medical attention
Setting 1:
mild hypertension| 140 – 159| 90 – 99| regular monitoring by doctor
High normal| 130 – 139| 85 – 89| regular monitoring by doctor
Normal| 120 – 129| 80 – 84| self-monitoring
Optimal| < 120| < 80| self-monitoring
Source: World Health Organization (WHO)

Setting 3
severe hypertension

Setting 2
moderate hypertension

Setting 1
mild hypertension

High normal

Normal

Optimal

BM67 Blood Pressure Monitor

beurer logo x1

No. 1 health care brand in Europe

beurer BM67 Blood Pressure Monitor 2a

Manufactured for:

Beurer North America LP,
900 N Federal Hwy Ste 300                     Model: BM67
Hallandale Beach, FL 33009                    Type: MD3600
Made in China                                         711.962-0317

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals