Basic safety precautions should always be followed, including the following:
Failure to follow instructions can cause severe injury and/or death.
** This is the safety alert symbol. When you see this symbol on your
equipment or in this manual, look for one of the following signal words and be
alert to the potential for personal injury.
WARNING warns about hazards that could cause serious personal injury,
death or major property damage and if ignored presents a potential hazard.
CAUTION warns about hazards that will or can cause minor or moderate
personal injury and/or property damage and if ignored presents a potential
hazard. It can also make consumers aware of actions that are unpredictable and
unsafe.
The NOTICE label indicates special instructions that are important but not
related to hazards.
SAVE THIS INSTRUCTION MANUAL**
SAFETY INFORMATION
- The filters are designed to work with water at temperatures>than 0°C (32°F) and <than 45°C. (113° F) The filter should never be operated outside of these temperatures or damage may occur.
- The installation should be carried out in accordance to the safety instructions of swimming pools and the specific instructions for each facility
- The user should make sure that the installation is carried out by qualified authorized persons and that these persons have first carefully read the following instructions. Incorrectly installed equipment may fail, causing severe injury or property damage
- The operating safety of the filter is only guaranteed if the installation and operation instructions are correctly followed.
- To reduce the risk of injury, do not permit children to use this product
- Chemical spills and fumes can weaken the Swimming Pools/Spas. Corrosion can cause filters and other equipment to fail, resulting in severe injury or property damage. Do not store pool chemicals near your equipment.
- Any modification of the filter requires the prior consent from the supplier’s original replacement parts and accessories authorized by the manufacturer ensure a high level of safety. The supplier assumes no liability for the damage and injuries caused by unauthorized replacement parts and accessories.
- In the event of defective operation or fault, contact the supplier or its nearest authorized service agent
THE FILTRATION SYSTEM WORKING PRINCIPLE
Incoming water from the piping system is automatically directed by the Multiport Valve to the top of the fitter bed. As the water is pumped through the filter, dirt and debris are trapped by the filter, and filtered out. The filtered water is returned from the bottom of the filter tank, through the Multiport Valve and back through the piping system.
PREPARATION BEFORE INSTALLATION
- Position the fitter as close to the Swimming Pool/ Spa as possible.
- The filter should be placed on a level concrete slab, very firm ground, or equivalent. Ensure that the ground will not subside, preventing any strain from the attached plumbing.
- Position the filter under consideration of the piping connections, so that it is convenient for operating and servicing.
- Ensure that the compliance label is facing the front to allow easy identification in the case of service difficulties.
**WARNING – Read and follow all instructions in this owner’s manual and
on the equipment. Failure to follow instructions can cause severe injury
and/or death.
** WARNING – Suction Entrapment Hazard. Suction in suction outlets
and/or suction outlet covers that are, damaged, broken, cracked, missing, or
unsecured can cause severe injury and/or death due to the following entrapment
hazards:
Hair Entrapment- Hair can become entangled in suction outlet cover.
Limb Entrapment- A limb inserted into an opening of a suction outlet sump
or suction outlet cover that is damaged, broken, cracked, missing, or not
securely attached can result in a mechanical bind or swelling of the limb.
Body Suction Entrapment- A negative pressure applied to a large portion
of the body or limbs can result in entrapment. Evisceration/
Disembowelment – A negative pressure applied directly to the intestines
through an unprotected suction outlet sump or suction outlet cover which is,
damaged, broken, cracked, missing, or unsecured can result in evisceration/
disembowelment.
Mechanical Entrapment- There is potential for jewelry, swimsuit, hair
decorations, finger, toe or knuckle to be caught in an opening of a suction
outlet cover resulting in mechanical entrapment.
** WARNING** – To Reduce the risk of Entrapment Hazards:
- When outlets are small enough to be blocked by a person, a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane (i.e. floor or wall), must be installed a minimum of three feet (3′) [1 meter] apart, as measured from near point to near point.
- Dual suction fillings shall be placed in such locations and distances to avoid “dual blockage” by a user.
- Dual suction fillings shall not be located on seating areas or on the backrest for such seating areas.
- The maximum system flow rate shall not exceed the flow rating of as listed on Table 2.
- Never use Pool or Spa if any suction outlet component is damaged, broken, cracked, missing, or not securely attached.
- Replace damaged, broken, cracked, missing, or not securely attached suction outlet components immediately.
- In addition two or more suction outlets per pump installed in accordance with latest NSPI, IAF Standards and CPSC guidelines, follow all National, State, and Local codes applicable.
- Installation of a vacuum release or vent system, which relieves entrapping suction, is recommended.
** WARNING – Failure to remove pressure test plugs and/or plugs used
in winterization of the pool/spa from the suction outlets can result in an
increase potential for suction entrapment as described above.
** WARNING – Failure to keep suction outlet components clear of
debris, such as leaves, dirt, hair, paper and other material can result in an
increase potential for suction entrapment as described above.
** WARNING – Suction outlet components have a finite life, the
cover/grate should be inspected frequently and replaced at least every ten
years or if found to be damaged, broken, cracked, missing, or not securely
attached.
** CAUTION- Components such as the filtration system, pumps and heater
must be positioned so as to prevent their being used as means of access to the
pool by young children.
**WARNING – Never operate or test the circulation system at more than
40 PSI.
** CAUTION – All electrical wiring MUST be performed by a qualified
professional, and MUST conform to local codes and regulations.
** WARNING – Never change the filter control valve position while the
pump is running.
** WARNING – Hazardous Pressure. Pool and spa water circulation
systems operate under hazardous pressure during start up, normal operation,
and after pump shut off. Stand clear of circulation system equipment during
pump start up. Failure to follow safety and operation instructions could
result in violent separation of the pump housing and cover, and/or filter
housing and clamp due to pressure in the system, which could cause property
damage, severe personal injury, or death. Before servicing pool and spa water
circulation system, all system and pump controls must be in off position and
filter manual air relief valve must be in open position. Before starting
system pump, all system valves must be set in a position to allow system water
to return back to the pool. Do not change filter control valve position while
system pump is running. Before starting system pump, fully open filter manual
air relief valve. Do not close filter manual air relief valve until a steady
stream of water (not air or air and water) is discharged.
** WARNING** – Separation Hazard. Failure to follow safety and operation
instructions could result in violent separation of pump and/or filter
components. Strainer cover must be properly secured to pump housing with
strainer cover lock ring. Before servicing pool and spa circulation system,
filters manual air relief valve must be in open position. Do not operate pool
and spa circulation system if a system component is not assembled properly,
damaged, or missing. Do not operate pool and spa circulation system unless
filter manual air relief valve body is in locked position in filter upper
body.
** WARNING – Electrical Ground motor before connecting to electrical
power supply. Failure to ground pump motor can cause serious or fatal
electrical shock hazard
** ** WARNING – Do NOT ground to a gas supply line.
** WARNING – To avoid dangerous or fatal electrical shock, turn OFF
power to motor before working on electrical connections.
** WARNING** – Failure to bond pump to pool structure will increase risk
for electrocution and could result in injury or death. To reduce the risk of
electric shock, see installation instructions and consult a professional
electrician on how to bond pump. Also, contact a licensed electrician for
information on local electrical codes for bonding requirements.
INSTALL THE FILTER TANK
Remove the pump and filter, as shown below for installation
INSTALLATION NOTES:
- Make sure the filter is working under the proper pressure and using a pressure control valve when the system requires a booster pump.
- If the pump position is higher than the water level, it requires the installation of a backwater control valve.
- If the pump position is lower than the water level, it requires the installation of an isolation valve. It could stop the water return back when people do the general inspection.
- When connecting hoses to the fittings and the pool, reduce bending the hoses to a minimum so as to not decrease the flow of water, and provide maximum efficiency.
- Ensure solvents are not excessively applied to fittings as this may destroy the 0-rings, and potentially create seal/leak issues.
- Do not overtighten fittings or adapters
HOW TO USE
-
Inspect and make sure that all connections have been made are correct and secure. Loosen the top of the filter bleed plug to exhaust the system of air inside filter vessel.
-
Prime and start pump according to pump instructions.
NOTE: ALL SUCTION AND DISCHARGE VALVES MUST BE OPEN WHEN STARTING THE SYSTEM. FAILURE TO DO SO MAY CAUSE SEVERE PERSONAL INJURY. MAKE SURE THE WATER LEVEL IN FILTER VESSEL IS FULL. IF NOT, FILL WITH WATER BEFORE STARTING UP THE PUMP, OR IT WILL DAMAGE THE PUMP. -
Once water flow is steady out the filter bleed plug, run the pump for 1-2 minutes. Then turn off the pump and tighten the bleed plug.
-
Again, prime and start the pump according to pump instructions. Your filter is now operating in the normal filter mode.
NOTES:
- Clarity of pool water depends on regular inspection of system, and replacement of cartridge filter element
- IMPORTANT: To prevent unnecessary strain on the piping system and valves, always shut off pump before switching the control valve position.
- To prevent damage to the pump and filter and for proper operation of the system, clean pump strainer and skimmer baskets regularly.
THIS UNIT HAS A ONE-YEAR LIMITED WARRANTY FROM MANUFACTURER DEFECTS. To extend the life of your filter pump:
- Actual filter run time depends on pool size/ gallons & HP of the pump. See online calculators.
- The average run time is approx. 8 hours a day to circulate & clean pool water
- Adjust run time to 10-12 hours as needed for larger pools, multiple bathers & algae growth,etc.
- Never run your pump 24 hours consecutively. This will void the warranty.
- We recommend running in Non-Consecutive Hour cycles; no more than 6-8 hours at a time.
- Run off peak hours, using an after-market timer to maximize utility savings.
REF # | ILP # | DESCRIPTION | OTY |
---|---|---|---|
1 & 2 | 70004 | DRAIN PLUG WITH GASKET | 2 |
3 | 70001 | LID & 0-RING FOR 70026 | 1 |
4 | 70001 | LOCKNUT | 1 |
5 | 71005 | 20 INCH PRECISION FILTER | 1 |
6 | 70012 | 0-RING ONLY FOR 70026 LID | 1 |
7 | 70026 | CARTRIDGE FILTER BODY | 1 |
8 | 70006SP | HOSE ADAPTER | 2 |
9 | 70006SP | 0-RING | 1 |
10 | 70006SP | ADAPTOR | 1 |
11 | 70006SP | 0-RING | 2 |
12 | 71206 | HYDRO-FLO AG .3 THP PUMP (VERTICAL DISCHARGE) | 1 |