LEVITON DOS05-1LZ Decora Motion Sensor In-Wall Instruction Manual

June 6, 2024
Leviton

Single Pole and 3 Way with 3-Way Switch Application
Wide View Motion Activated Light Control
Cat. Nos. DOS05, DVS05 – INDOOR USE ONLY
Ratings: 120VAC, 60Hz 600 W Incandescent, 5 A Resistive, 300W LED and CFL, 400 VA ELV/MLV, 1/4 HP Motor

WARNINGS
• TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
• TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle or a load in excess of the specified rating.
• To be installed and/or used in accordance with electrical codes and regulations.
• If you are not sure about any part of these instructions, consult an electrician.

CAUTIONS
• To clean use a damp cloth with mild soap. DO NOT use disinfecting products, including foggers, sprays, or other types of atomized cleaning agents.
• no user-serviceable components. DO NOT attempt to service or repair.
• Use this device WITH COPPER CLAD WIRE ONLY.

INSTALLATION

Features

  • Cat. Nos. DOS05 and DVS05 have a sensing angle of 180° and a sensing area of coverage of 30 x 30 ft. See coverage diagram for details.
  • Adjustable ambient light (DOS05 only), time delay, and area of coverage controls. See the adjustment setting section for details.
  • Indicator light alerts the user of device status.
  • Adjustable time delay setting for 1, 5, 10, and 20 minutes plus a test mode with 5 seconds on. A Temporary Bypass mode that disables the Auto-on feature is available only for DOS05.

Mounting Location

  • The device responds to temperature changes and care should be taken when mounting the device.
  • DO NOT mount directly above a heat source, in a location where hot or cold drafts will blow directly on the sensor, or where unintended motion (e.g., hallway traffic) will be within the sensor’s field of view.

You Will Need:

  • Slotted/Phillips screwdriver
  • Cutters
  • Electrical tape
  • Pliers

Installation

WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn off power at circuit breaker or fuse, and test that the power is off before wiring.
1. Identify your wires (most common): 
NOTE: Neutral wire (if present), or a ground wire is required for operation. If the wiring in the wall box does not resemble this configuration, consult an electrician.
Single PoleLEVITON DOS05-1LZ Decora Motion Sensor In-
Wall

3-Way (Neutral NOT present)LEVITON DOS05-1LZ Decora Motion Sensor In-
Wall -fig

3-Way (Neutral present)LEVITON DOS05-1LZ Decora Motion Sensor In-Wall
-fig 1

NOTE: Sensor must be installed in the location where the load wire is.
2a. Wire (when Neutral is NOT present).
Working on one connection at a time, connect wires as shown.
NOTE: This device is designed so the line and load wires can be wired interchangeably.
Single PoleLEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
2

3-Way
NOTE: To control the load from the 3-way switch, toggle once to turn the load ON and twice to turn the load OFF.LEVITON DOS05-1LZ Decora Motion
Sensor In-Wall -fig 3

2b. Wire (when Neutral is present).
Remove the GREEN sleeve from the white wire. Working on one connection at a time, connect wires as shown.
NOTE: This device is designed so the line and load wires can be wired interchangeably.
Single PoleLEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
4

3-Way
NOTE: To control the load from the 3-way switch, toggle once to turn the load ON and twice to turn the load OFF.LEVITON DOS05-1LZ Decora Motion
Sensor In-Wall -fig m

3. Test and mount.

  • Restore power. Wait 10-20 seconds for the sensor to power up.
  • DOS05: lights will automatically turn ON with the first motion seen after warm-up period, or press push pad.
  • DVS05: press the push pad. Lights should turn ON.

NOTE: If lights do not turn ON, refer to the “What to do if…” section.
Turn off power at the circuit breaker before completing the installation.

  • Gently push wires into the wall box. Screw light control to the box.
  • Install wallplate.
  • Restore power.

Operation

LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig 5

NOTE: Press either TOP or BOTTOM of a button to turn ON/OFF.

Programming

1. How to change the settings.

How to choose a setting and option


In order to…

| Do this…|

Indicator light will..

Enter programming mode| Hold TOP and BOTTOM button for 5 seconds|

The GREEN light will be solid ON for 5 seconds.
NOTE: If nothing happens, the device is already in programming mode

Change settings (Timer,
Sensitivity, Ambient Light)| Single press TOP button = advance to the next setting (see table below)| RED light will blink to indicate column selected (Timer ->Sensitivity -Ambient Light ->Timer) (Example: Column 1 = 1 blink/sec)
Change options within a
setting| Single press BOTTOM button = advance to the next option (see table below)| The GREEN light will blink to indicate the option selected
Examples: Option 1 = 1 blink/sec Option 2 = 2 blinks/sec
Save and exit settings| Hold either TOP or BOTTOM button
for 5 seconds|

The GREEN light will be solid ON for 5 seconds

NOTE: If there is no activity for 30 seconds, the device will automatically exit programming mode, and setting changes will not be saved. Multiple settings can be saved by entering the programming settings once, selecting desired settings, and then saving and exiting.

Setting Types and Options (defaults are in bold)


Option Number| Column 1| Column 2| Column 3
TIMER
(Duration of time for which load is ON since last detected motion)| SENSITIVITY
(Sensitivity to motion – adjusting the major and minor detection range.)| DOS05 ONLY – AMBIENT LIGHT
(If the room is brighter than the setting selected, the load will not turn ON.)
Option 1| 1 minute| Low (50% Range)| Low Light level
Option 2| 5 minutes| Medium| Medium Light level
Option 3| 10 minutes| High| High/Brightest light level
Option 4| 20 minutes| All settings to default| Disabled – turns ON for all light levels

2. When to use occupancy or vacancy.

Modes| When to use this setting| Time| Amount of Ambient Light Present| Turns light ON when…| The light turns OFF when…
---|---|---|---|---|---
Occupancy (DOS05 only)| When automatic ON/OFF lighting control is desired.| Any| 1.  Low – Light will turn ON automatically if the room is darkest.
2.  Medium – Light will turn ON automatically if the room has more light.
3.  High – Light will turn
ON automatically if the room has the mostlight.
4.  Disabled – Light will turn ON always.| The user walks into the view of the sensor when the light is OFF and it is darker than the ambient light level set. OR TOP or BOTTOM of a button is pushed.| No motion is detected for the duration of the programmed time period. OR TOP or BOTTOM of a button is pushed.
Vacancy| 15 FT When Manual ON, Automatic OFF lighting control is desired.| Any| N/A| TOP or BOTTOM of a button is pushed. OR User moves around within 30 secs of the light turning OFF.| TOP or BOTTOM of a button is pushed. OR  No motion is detected for the duration of the programmed time period.

Occupancy/Vacancy Switch (DOS05 only)
Remove color kit and wallplate to access.LEVITON DOS05-1LZ Decora Motion
Sensor In-Wall -fig 8

Changing your device color

Remove Replace

LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig 6| LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
7

3. Using advanced modes.

Model name

| To enable this mode…|

The device will…

---|---|---
Test Mode| Press and hold TOP of a button for 5 seconds. To exit, press the TOP or BOTTOM button or it will automatically exit after 2 minutes.| Turn on the load for 5 seconds every time motion is detected. A RED light will blink lx/2 sec when in Test Mode. The locator LED function is disabled while the motion detection function is active.
Temporary Bypass
Mode
(Available for
occupancy sensors only)| Press and hold BOTTOM of a button for 5
seconds. To exit, press TOP or BOTTOM
of button.| Ignore motion keeping the light/load off.
The GREEN light will double flash every 2 seconds.
Programming Mode
(See Programming
directions below)| Hold TOP and BOTTOM of a button for 5 seconds.| The GREEN light will be solid ON for 5 seconds. NOTE: If nothing happens, the device is already in programming mode.

Sensing Area Coverage

  1. Horizontal field of view:
    LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig 9 Major motion coverage 900ft 2
    Minor motion coverage 400ft2

  2. Vertical field of view:

What to do if…


Issue|

Make this adjustment

Lights do not operate with the push pad and the RED indicator does not blink when motion is present|

  • Verity wiring connections to sensor.

Lights do not switch ON when motion is detected – DOS05|

  • Motion is beyond sensing range – move closer to switch.
  • Adjust the light level lower (Option 3, 2, 1 or disable).
  • The RED light will blink to indicate motion. If it is blinking and the load is not turning ON, it could be due to ambient light OR it checks to make sure that the Occ-Vac switch is in OCC position.

Lights always stay ON|

  • Check time delay settings and compare to how long the lights stay ON.
  • Make sure no motion occurs in the coverage area for the time selected by covering the lens.
  • Check that switch is not installed near a heat source (like stove, lights, heat vents) or detect motion from an adjacent area (like hallway traffic) and if it is, relocate it.

Lights do not turn ON – DVS05   |

  • Make sure that control is installed correctly.
  • Make sure the power is ON.
  • Check to make sure the light bulb is functional.

FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving Antenna.
  •  Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/tv technician for help.

FCC CAUTION: Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1-800-405-5320.
LIMITED 5 YEAR WARRANTY For Leviton’s limited product warranty, go to www.leviton.com. For a printed copy of the warranty, call 1-800-824-3005.

Patents covering this product, if any, can be found on www.leviton.com/patents.
Leviton and Block and Design logo is a registered trademark and Decora is a trademark of Leviton Mfg. Co., Inc.
For Technical Assistance Call: 1-800-824-3005 (USA Only)
or 1-800-405-5320 (Canada Only) www.leviton.com
© 2020 Leviton Mfg. Co., Inc.
PK-A3346-10-00-2A-X4

ARTWORK PRINT SPECIFICATIONS

PART NUMBER—— PK-A3346-10-00-2A-X4 ———REV———–DESCRIPTION————- -Instruction Sheet
Artwork must be printed at 100% (1:1 scale)
Material Specifications: North America Suppliers
*Thickness:* 0.0040/ 0.0038
Material: 20lb Bond / 50lb Offset Paper
Recycled Content: N/A
Exterior** Brightness:  95/ 89-92
*Finish: N/A/ Smooth or Vellum

Material Specifications: Asia Suppliers

*Thickness:* 0.003/ 0.0027
Material:** 55G / 60G Offset Paper

  • Recycled Content: N/A
    *Exterior Brightness* : 90
    Finish:** N/A
    *For manuals – designates cover specifications
    Color:
    No. of Color(s):
    -1—— over 1—–
    1: Black——–
    2: ————– Spot
    3: ————–
    4:———— -CMYK

Fonts:
1: ——– -Helvetica
2: ————–
3: ————–
4:———–
Die Line Key:LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
14p

MANUAL INTERIORS / BINDERY / FOLD SCHEME :

LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
hhhh

Fonts:
1:————–
2:————–
3:————–
4:————–
DIMENSIONS / FOLD SCHEME / BINDERY DIAGRAM
LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig
15

PROCESS :

LEVITON DOS05-1LZ Decora Motion Sensor In-Wall -fig tt

COMMENTS :
————————————————————
——————

The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed with the understanding that acceptance or review by the recipient constitutes an undertaking by the recipient. (1) to hold this information in strict confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any purpose other than that for which disclosed.

FOR LEVITON USE ONLY

LEVITON DOS05-1LZ Decora Motion Sensor In-sdss

LEVITON DOS05-1LZ Decora Motion Sensor In-Waooll

Artwork Print Specification Sheet Rev A13.ep

Documents / Resources

| LEVITON DOS05-1LZ Decora Motion Sensor In- Wall [pdf] Instruction Manual
DOS05-1LZ, Decora Motion Sensor In-Wall
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals