INSTALLATION INSTRUCTIONS

Features

  • Easy operation with four preset buttons and one “OFF” button.
  • Simple press and hold override function for 24-hour override.
  • For Single-Pole wiring only.
  • With Zero Cross turn-ON technology that extends the life of the switching relays (turns ON at the minimum voltage).
  • Color change kits are available in white, light almond, ivory, black, brown, and gray (DTKIT-00x).
  • Available with six countdown timer options (15, 30, 60 minutes, and 2, 4, 12 hours).
  • Available in a 20A larger load, multi-way, or multi-timer (Cat. No. DT2xx).

You Will Need:

  • Slotted/Phillips screwdriver
  • Electrical tape
  • Cutters
  • Pliers

Installation
WARNING: TO AVOID FIRE, SHOCK OR DEATH, turn OFF power at circuit breaker or fuse and test that the power is OFF before wiring!
Identify your wires (most common shown).
NOTE: A Neutral wire (if present) or a Ground wire is required for operation. If the wiring in the wallbox does not resemble this configuration, consult an electrician.

**No Neutral Wire

With Neutral Wire

Wire device (when Neutral is NOT present).
Work on one connection at a time, and connect wires as shown.
NOTE: This device is designed so that the line and load wires can be wired interchangeably.

Wire device (when Neutral is present).**

  • Remove the green sleeve from the white wire.
  • Work on one connection at a time, and connect the wires as shown.

NOTE: This device is designed so that the line and load wires can be wired interchangeably.

Test and mount

  • Restore power. Wait 20 seconds for timer to power up.
    NOTE: The bottom green LED blinks once every 5 seconds during power up.

  • Press any timer button to turn the load ON.
    NOTE: If load does not turn ON, refer to the “What to do if…” section.

  • Turn OFF power at circuit breaker before completing the installation.

  • Gently push wires into wallbox. Use the screws to attach timer to wallbox.

  • Install wallplate.

  • Restore power.

LED Location and Status

  • Four (4) timer buttons and an OFF button.
  • Each timer button has an adjacent green LED to indicate the current countdown time.
  • The green bottom Locator LED is ON when the load is OFF, and it is OFF when the load is ON.
Mode Location Status
Power Up Next to OFF button Blinks once every

5 seconds.
Load OFF| Next to OFF button| ON
Load ON| Next to Button
1, 2, 3, or 4| ON
24-Hour Timer Override| Next to Button 1| Blinks once per second.
Last Minute Load Is ON| Next to Button 4| Blinks once per second.

Operation

  1. To turn the load ON, press one of the timer buttons. Each button has a preset countdown time. The green LED adjacent to the selected button illuminates, and the load stays on for the selected time period.
  2. To select a different countdown time, press the button that corresponds to the desired time. The LED adjacent to the selected button illuminates, and the load stays on for the newly selected timer period.
  3. To turn the load OFF, press the OFF button, or wait until the selected amount of time elapses. The LED adjacent to each button turns OFF as time passes to the next lower preset level.

Timer Override
To override the timer countdown, press and hold the top button for more than 5 seconds. The LED blinks once per second to indicate the timer is in the EXTENDED ON state. The timer automatically turns OFF after 24 hours. To exit the EXTENDED ON state, press any timer button or the OFF button.

Model DT115| | Countdown Timer Options|
---|---|---|---
Button 1| Button 2| Button 3| Button 4| Button 5
15 minutes| 10 minutes| 5 minutes| 2 minutes| Off
DT130| 30 minutes| 15 minutes| 10 minutes| 5 minutes| Off
DT160| 60 minutes| 30 minutes| 20 minutes| 10 minutes| Off
DT102| 2 hours| 1 hour| 30 minutes| 15 minutes| Off
DT104| 4 hours| 2 hours| 1 hour| 30 minutes| Off
DT112| 12 hours| 8 hours| 4 hours| 2 hours| Off

**Changing Your Device Color

**

Color change kits are available in white, light almond, ivory, black, brown, and gray (DTKIT-00x).

What to do if…

  • Intermittent operation
    • Check that the load does not have a bad connection.
    • Check if wires are secured firmly to the leads of timer switch.
  • Load does not turn ON and Locator LED does not turn ON
    • Check if the circuit breaker or fuse has tripped.
    • Check if the load has burned out.
    • Make sure the Neutral or Ground connection is wired properly.
    • Make sure that the green-sleeved wire is connected properly.

FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation of the device. This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Consult the dealer or an experienced radio/TV technician for help.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

FCC CAUTION:
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc., could void the user’s authority to operate the equipment.

IC STATEMENT
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device

Patents covering this product, if any, can be found on www.leviton.com/patents

Leviton and the Leviton logo are the registered trademarks of Leviton Manufacturing. Co., Inc.

FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada ULC the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.

LIMITED 5 YEAR PRODUCT WARRANTY
For Leviton’s limited 5 year product warranty, go to www.leviton.com. For a printed copy of the warranty you may call 1-800-323-8920 or write to Leviton Manufacturing Co., Inc., Att: Customer Service Dept., 201 North Service Road, Melville, New York 11747.

© 2023 Leviton Mfg. Co., Inc

  • For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com.

WARNINGS:

  • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING!
  • TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, or a load in excess of the specified rating.
  • DO NOT use to control lighting if it is the only light source in the area.
  • To be installed and/or used in accordance with electrical codes and regulations.
  • If you are not sure about any part of these instructions, consult an electrician.

CAUTIONS:

  • DO NOT use disinfecting products, including foggers, sprays or other types of atomized cleaning agents.
  • DO NOT spray liquid onto the product.
  • To clean, use a damp cloth with mild soap.
  • No user serviceable components. DO NOT attempt to service or repair.
  • Use this device WITH COPPER OR COPPER-CLAD WIRE ONLY

Documents / Resources

| LEVITON DT102-1LW Single Pole Electronic Countdown Timer [pdf] Instruction Manual
DT102-1LW Single Pole Electronic Countdown Timer, DT102-1LW, Single Pole Electronic Countdown Timer, Pole Electronic Countdown Timer, Electronic Countdown Timer, Countdown Timer
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals