UBIQUITI USW-Pro-48 Port Gigabit Managed Switch with SFP+ User Guide

June 6, 2024
UBIQUITI

USW-Pro-48 Quick Start Guide

Package Contents

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch

System Requirements

  • Linux, Mac OS X, or Microsoft Windows 7/8/10
  • Java Runtime Environment 1.6 (1.8 or newer recommended)
  • Web Browser: Google Chrome (Other browsers may have limited functionality.)
  • UniFi Controller software v5.12.x (or newer), available at: ui.com/download/unifi

IMPORTANT: We strongly recommend using UPS backup and power regulation to prevent equipment damage due to stability issues with local AC power.

Hardware Overview

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Hardware
OverviewUBIQUITI USW-Pro-48 Port
Gigabit Managed Switch-Hardware Overview 2

1. Touchscreen Display

Bootup Animation| Initializing.
Steady White| Factory defaults, waiting for adoption.
Steady Blue| Successfully adopted by a network and working properly.
Location Animation| This indicates that you clicked Locate in the UniFi
Controller software. The software will also display the location of the device on the map.
2. RJ45 Speed/Link/Activity LED (Ports 1 – 48)
Off| No Link
Amber| Link Established at 10/100 Mbps
Flashing Indicates Activity
Green| Link Established at 1000 Mbps
Flashing Indicates Activity
3. SFP+ Speed/Link/Activity LED (Ports 49 – 52)
Off| No Link
Green| Link Established at 1 Gbps
Flashing Indicates Activity
White| Link Established at 10 Gbps
Flashing Indicates Activity
4. RJ45 (Ports 1 – 48)
RJ45 ports support 10/100/1000 Ethernet connections.
5. SFP+ (Ports 49 – 52)
Hot-swappable SFP+ ports support 1/10 Gbps connections.
6. Reset Button
This button serves two functions for the UniFi Switch:
Restart Press and release the Reset button quickly.
Restore to Factory Default Settings Press and hold the Reset button for more than five seconds.
7. USP LED
The LED lights up blue when there is an active power connection on the USP DC input.
8. USP Connect DC Input
UniFi SmartPower Redundant Power System, model USP-RPS, via the USP Cable (not included). If there is an AC power loss or internal power supply failure, the UniFi Switch will draw power from the USP-RPS instead.
9. Power Port
Connect the included Power Cord to the Power port.

Installation Requirements

  • Phillips screwdriver
  • Standard-sized, 19″ wide rack with a minimum of 1U height available
  • For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections and should be grounded through the AC ground of the power supply.

We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable

Note: Although the cabling can be located outdoors, the UniFi Switch itself should be housed inside a protective enclosure.

Hardware Installation

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Hardware Installation
1UBIQUITI USW-Pro-48 Port
Gigabit Managed Switch-Hardware Installation 2UBIQUITI USW-Pro-48 Port Gigabit
Managed Switch-Hardware Installation 3

Connecting Power

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Hardware Installation
4

Connecting Ethernet

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Connecting
Ethernet

Connecting SFP

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Connecting SFP
1

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Connecting SFP
2

For information about compatible fiber SFP modules, visit ubnt.link/UniFi_SFP_DAC_Compatibility

Software Installation

Note: If you already have UniFi Controller v5.12.x or higher installed, go to the section, Adopting the UniFi Switch.
After you have installed the software and run the UniFi Installation Wizard, a login screen will appear for the UniFi Controller management interface.  enter the username and password that you created and click Sign In.

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Sign
In

You can manage your network and view network statistics using the UniFi Controller management interface.
To adopt the UniFi Switch, proceed to the section, Adopting the UniFi Switch.
For information on configuring and using the UniFi Controller software, refer to the User Guide on the website: ui.com/download/unifi

Adopting the UniFi Switch

  1.  From the UniFi Controller dashboard, click Devices in the left menu bar.UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-UniFi Switch 1
  2. On the Devices screen, locate the UniFi Switch in the list of devices under the Model column. To adopt the UniFi Switch, click Adopt.UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-UniFi Switch 2
  3. The display will turn blue to confirm that the UniFi Switch has been successfully adopted.

Specifications

USW-Pro-48


Dimensions| 442.4 x 285.4 x 43.7 mm (17.42 x 11.24 x 1.72)
Weight

With Rackmount Brackets

| 4.00 kg (8.82 Ib)
4.09 kg (9.02 Ib)
Interfaces
Networking Management| (48) 10/100/1000 RJ45 Ports
(4) 10G SFP+ Ethernet Ports
Ethernet In-Band
Power Method
Universal Input
USP RPS DC Input| 100-240VAC, 50/60 Hz 11.5VDC, 5.22A
Power Supply| AC/DC. Internal, 60W
Supported Voltage Range| 100 to 240VAC
Max. Power Consumption| 60W
LEDs
RJ45 Data Ports
SFP+ Data Ports| Speed/Link/Activity Link/Activity
ESD/EMP Protection| Air: ± 16 kV. Contact: ± 12 kV
Shock and Vibration| ETSI300-019-1.4 Standard
Operating Temperature| -5 to 45′ C (23 to 113′ F)
Operating Humidity| 10 to 90% Noncondensing
Certifications| CE, FCC, IC

Safety Notices

  1. Read, follow and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Failure to provide proper ventilation may cause fire hazards. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.
WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.
WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.

  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.

  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    a. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    b. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    c. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    d. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    e. Protective bonding must be installed in accordance with local national wiring rules and regulations.

  4. The product is used in Service Access Area.

Limited Warranty

ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment, this equipment may cause radio interference.
CE Marking

WEEE Compliance Statement
Declaration of Conformity
Online Resources

UBIQUITI USW-Pro-48 Port Gigabit Managed Switch-Online
Resources

© 2021 Ubiquiti Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals