PERLESMITH PSDSK2-1 Floating Wall Mounted Shelf Instruction Manual
- June 6, 2024
- Perlesmith
Table of Contents
Floating Wall Mounted Shelf Instruction Manual
V2.0
Model: PSDSK2-1
Thank you for choosing this PERLESMITH product! At PERLESMITH we strive to provide you with the best quality products and services in the industry. Should you have any issues, please don’t hesitate to contact us at
Technical Support:
1-800-556-6806 Mon-Fri 8am – 8pm(CST)
Other Info:
supportus@perlesmith.com(US)
supportca@perlesmith.com(CA)
IMPORTANT SAFETY INFORMATION
-
WARNING! SEVERE PERSONAL INJURY AND PROPERTY DAMAGE CAN RESULT FROM IMPROPER INSTALLATION OR ASSEMBLY. READ THE FOLLOWING WARNINGS BEFORE BEGINNING.
-
If you do not understand the instructions or have any concerns or questions, please contact us at supportus@perlesmith.com (US)/supportca@perlesmith.com (CA).
-
Do not install or assemble if the product or hardware is damaged or missing. Not all parts and hardware included must be used. If you require replacement parts, contact customer service at supportus@perlesmith.com (US)/supportca@perlesmith.com (CA).
-
Do not attempt to install or assemble this product if the product or hardware is damaged or missing. The included hardware is designed for use on vertical walls constructed of wood studs or concrete. A wood stud wall is defined as consisting of a minimum of 2×4 wooden studs (2” width by 4” depth)
with a maximum of 5/8” drywall. The included hardware is not designed for use with metal studs or drywall. If you’re uncertain about the construction of your wall, then please consult a qualified contractor or installer for assistance. -
For a safe installation, the wall you are mounting to must support 4 times the weight of the total load. If not, then the surface must be reinforced to meet this standard. The installer is responsible for verifying that the wall structure and hardware used in any installation method will safely support the total load.
Weight Restrictions
CAUTION!
DO NOT exceed the maximum weight indicated. This mounting system is intended for use only within the maximum weights indicated. Use with products heavier than the maximum weights indicated may result in failure of the mount and its accessories, causing damage and or injury.
Tools Needed (Not lncluded)
Supplied Parts and Hardware
Wall Kits
|
Shelf Kits
| |
1a MOUNT WALL PLATE ON WOOD STUD WALL
WARNING:
-
Avoid potential personal injury or property damage! DO NOT over-tighten the lag screws [W-A-1]. Tighten the lag screws [W-A-1] only until the washers
[W-A-2] are pulled firmly against the wall plate. -
DO NOT USE ANCHOR [W-B] FOR THIS STEP!
-
Ensure the wall plate [A] is securely fastened to the wall before continuing to the next step.
-
Any material covering the wall must not exceed 5/8 in (16 mm).
-
Nominal wood stud size: common 2 x 4 in (51 x 102 mm) minimum 1½ x 3½ in (38 x 89 mm).
-
Stud center must be verified.
1) Use a stud finder to locate wood stud and mark the edge and center
location.| 2) Position the wall plate [A] at your desired height and line
up the holes with your stud centerline. Level the wall plate and mark 2 holes.
---|---
|
3) Drill pilot holes using a 1/8 in (3.2 mm) diameter drill bit.| 4)
Secure the wall plate [A] with the lag screws [W-A-1] and washers [W-A-2].
|
1b. MOUNT WALL PLATE ON CONCRETE BLOCK OR SOLICK BRICK
WARNING:
-
Avoid potential personal injury or property damage! DO NOT over-tighten the lag screws [W-A-1]. Tighten the lag screws [W-A-1] only until the washers
[W-A-2] are pulled firmly against the wall plate [A]. -
Ensure the wall plate is securely fastened to the wall before continuing to the next step.
-
Any material covering the wall must not exceed 5/8 in (16 mm).
-
Mount the wall plate [A] directly onto the concrete surface.
-
Minimum solid concrete thickness: 203 mm (8 in).
-
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in).
-
Never drill into the mortar between blocks.
-
CAUTION: Secure the glass shelf to the lower glass shelf support at first, then secure the topper shelf.
1) Position the wall plate [A] at your desired height, level the wall
plate [A], and mark 2 pilot hole locations.| 2) Drill 2 pilot holes into
a concrete wall.
---|---
|
INSTALL THE TEMPERED GLASS
1) Connect the connector [E] to glass shelf support [G] with bolts [S-A] and Allen key [S-B] as shown in Fig.2.1 and keep about 1/8in(3mm) spacing left between the connector with glass shelf support as shown in Fig. 2.2.
2) Insert the glass shelf support [G] along the wall plate rail at the
desired height respectively.| 3) Firmly tighten the bolts [S-A] with
Allen key [S-B].
---|---
|
4) Paste the pads [F1 and F2] to glass shelf support [G] respectively.|
5) Secure glass shelf [C] to glass shelf support [G].
| CAUTION : Secure the glass shelf to the lower glass shelf
support at first, then secure the topper-shelf one.
ADD END CAPS AND PLUGS
Option A
3A-1 Manage the cables along with the cable manager
3A-2 Add one of the end caps to the bottom of the wall plate, then insert the
cable manager with cables into the wall plate
3A-3 Add end caps and plugs into the wall plate
Option B
3B-1 Insert the cable manager with cables into the wall plate
3B-2 Add end caps and plugs into the wall plate
3B-3 Manage the cables along with the cable manager
Thank you again
for choosing this PERLESMITH product!
All of us at PERLESMITH do appreciate your product purchase. We hope that you are as happy with your product as we designing and manufacturing it for you. We strive to provide you with the best quality products and services in the industry. If you have any questions please don’t hesitate to contact us at
Technical Support:
1-800-556-6806 Mon-Fri 8am –
8pm(CST)
Other Info:
supportus@perlesmith.com(US)
supportca@perlesmith.com(CA)