SDC 30-4 Rim Mount Electric Strike Installation Guide

June 6, 2024
SDC

INSTALLATION INSTRUCTIONS
30-4
RIM MOUNT ELECTRIC STRIKE

Specifications:

Voltage:| .51 Amps @ 12 VDC

.25 Amps @ 24 VDC

---|---
Models:| 30 – 4 – 12

30 – 4 – 24

Options:| FS – Fail-Safe

LCBMA-30 – Latch & Locking cam monitoring

Any suggestions or comments on this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

CAUTION!
Before connecting any device at the installation site, verify input voltage using a multimeter. Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding 10% of the solenoid rating may cause severe damage to the unit and will void the warranty.

P reparing the Strike

  1. Attach the faceplate to the strike body using the #12-24 x 3/8″ Body Mounting screws as illustrated on Page 3.

  2. IF using the LCBMA (Latchbolt & Locking Cam Monitor), See the Image below for wiring instructions.
    NOTE: The strike body ships as either a 12 or 24-volt unit and do not field selectable.

  3. VERIFY the available voltage is +/- 10% of the rated voltage of the strike body.

  4. PREPARE frame using the dimensional reference on Page 4.

  5. TEST FIT the electric strike in the door frame.

  6. IF there is not enough clearance between the exit device and the door strike, THEN REMOVE the spacer plate as shown on Page 3.
    Finishing the Installation

  7. CONNECT the Plug Connector to the electric strike and CONNECT wires from the Plugin Connector lead to the power source.

  8. INSTALL the electric strike unit in jamb cutout, using the provided #12-24 x 1/2″ faceplate mounting screws

  9. ADJUST the strike horizontally as shown on Page 3. to accommodate any door silencers or smoke seal

Monitoring Switches

Latchbolt Monitor (LBM)

White:| COM
Orange:| N/O
Green:| N/C

Locking Cam Monitor (LCM)

Brown:| COM
Blue:| N/O
Yellow:| N/C

  • When secured

Attaching the Faceplate

  1. To attach the 30-4 series electric strike body to the faceplate, INSTALL with two #8-32 body mounting screws as shown.
  2. ADJUST the keeper position as needed before tightening screws.
  3. ENSURE body mounting screws are tightened and secured after adjustment is made.

Removing the 1/4″ Spacer Plate

NOTE:
A 1/ 4″ spacer plate is preinstalled on the striking faceplate. Removal of the spacer plate will decrease faceplate thickness from 3/4″ to 1/2″.

  1. REMOVE the four #8-32 screws and two #2-56 screws.
  2. REMOVE the spacer plate.

Adjusting the Horizontal

  1. LOOSEN the two #1/4 – 20 faceplate mounting screws.

  2. ADJUST the strike to the appropriate position.

  3. TIGHTEN the two #1 4 – 20 faceplate mounting screws.
    NOTE:
    A 3/8″ set screw is provided. Proper selection will secure the #1/ 4 – 20 faceplate mounting screws, but not protrude from the strike body.

  4. LOCKDOWN the adjustment by installing the provided set screws.

Strike Dimensions

| |
---|---|---

Dimensional Drawing Only Not Drawn to Scale

Frame Dimensional Cutout

SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: service@sdcsecurity.com ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011

P:\INST INSTRUCTIONS\ELECTRIC STRIKES\INST-30-4 Rev B 03-21

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals