DIGITUS DN-651114 Gigabit Ethernet PoE+ Injector User Manual

June 6, 2024
DIGITUS

DIGITUS DN-651114 Gigabit Ethernet PoE+ Injector User Manual

DIGITUS DN-651114 Gigabit Ethernet PoE+ Injector

1. Package Content

Thank you for purchasing Our Industrial Power over Ethernet Injector. Terms of “PoE Injector” in following section of this User’s Manual means the IPE30.

Upon open the box of the Industrial Power over Ethernet Injector and carefully unpack it. The box should contain the following items:

  • Industrial Gigabit Power over Ethernet Injector x 1
  • User’s Manual x 1
  • DIN Rail Kit x 1

If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair.

2. Description

The IPE30-DC is a single port Mid-spans offers a compact and cost effective, fully IEEE802.3at-4pair compliant solution for remote powering of wireless LAN (WAN) access points, IP Security cameras, VoIP telephone and other low port density installations.

The IPE30-DC PoE Mid-spans eliminates the need for external power supply and its associated AC/DC power cabling, providing a compact, affordable, safe and reliable power solution over existing Ethernet infrastructure.

3. Product Features

  • Full lEEE802.3af, IEEE802.3at Compliant
  • Up to 30W of Power on 2-pairs
  • Auto-detect of IEEE802.3af, IEEE802.3at PD
  • Supports 10/100/lOOOBase-T applications
  • LED indicators power input and PoE output indication
  • Distance up to 100 meters
  • DC lnput 4s-s6v
  • DIN-Rail installation
  • ESD protection level 6kV
  • DCIN port surge protection level 8/20us DM/CM 3KA
  • RJ45 port Surge protection level 10/700us DM/CM 6KV
  • Wide operating temperature: -40 – +75°C

Note

PD (Powered Device) is a PoE-enabled terminal by PSE and thus consumes energy, such as IP Phones, network cameras and Wireless access points, etc.

PSE (Power Sourcing Equipment) is a device (switch, or hub for instance) that will provide power in a PoE setup. Maximum allowed continuous output power per such device in IEEE 802.3af is 15.4W, 30W in IEEE 802.3at.

4. Product Specification

FIG 1 Product Specification

FIG 2 Product Specification

FIG 3 Product Specification

5. Hardware Description

5.1. Physical Dimension

FIG 4 Physical Dimension

FIG 5 Physical Dimension

FIG 6 Physical Dimension

5.2 Product Outlook

FIG 7 Product Outlook

LED Indicators

FIG 8 LED Indicators

5.3. Wiring the Power Inputs
The 3-contact terminal block connector on the top panel of Industrial PoE Injector is used for DC power input. Please follow the steps below to insert the power wire.

  1. Insert Positive I Negative DC power wires into the contacts 1 and 3 for POWER.

FIG 9 Wiring the Power Inputs

2. Tighten the wire-clamp screws for preventing the wires from loosing.

FIG 10 Pin of Terminal Block

Figure 4: Pin of Terminal Block

FIG 11 Pin of Terminal Block

Note

The wire gauge for the terminal block should be in the range between 12 – 24 AWG.

6. Mounting Installation

This section describes how to install the Industrial Equipment and make connections to it. Please read the following topics and perform the procedures in the order being presented.

Note

In the installation steps below, this Manual use 8 Port Industrial Gigabit Switch as the example. However, the steps for Industrial slim type Switch, Industrial Media I Serial Converter and Industrial PoE equipment are similar.

6.1. DIN-Rail Mounting
The DIN-Rail is already screwed on the Industrial Equipment. Please refer to following figures and know how to hang the Industrial Equipment:

Step 1: Lightly press the button of DIN-Rail into the track.

FIG 11 Install Industrial Equipment in DIN Rail mount

Figure 5: Install Industrial Equipment in DIN Rail mount.

Step 2: Check the DIN-Rail is tightly on the track.

FIG 12 Check the DIN-Rail is tightly on the track

Figure 6: Industrial Equipment installed in DIN-Rail mount.

6.2. Remove DIN Rail Mounting

Step 1: Please refer to following procedures to remove the Industrial Equipment from the track.

FIG 13 Remove DIN Rail Mounting

Figure 7: Remove Industrial Equipment in DIN-Rail mount.

Step 2: Lightly press the button of DIN-Rail for remove it from the track.

7. Hardware Installation

This Industrial IEEE 802.3at Gigabit High Power over Ethernet Injector provides three different running speeds – 10Mbps, 100 Mbps and 1 000 Mbps in the same device and automatically distinguishes the speed of incoming connection. Please refer to following sections for detail information about Industrial IEEE 802.3at Gigabit High Power over Ethernet Injector.

Before Installation
Before your installation, it is recommended to check your network environment. If there has any IEEE 803.3af or IEEE 802.3at devices need to power on, the PoE Injector can provide you a way to supply power for this Ethernet device conveniently and easily.

Installation

  1. Connect the Power (Range from DC 45 – 56V) to 3-pin terminal block of PoE Injector. The HPWR” LED will be steady on.
  2. Connect a standard network cable from Switch I workstation to HDATA” port of PoE Injector.
  3. Connect the long cable that will be used to connect to the remote device to the port HPOE OUT”‘.
  4. Due to the capability of IEEE 802.3at Power over Ethernet, the PoE Injector can directly connect with any IEEE 802.3at / IEEE 802.3af devices.
  5. Once PoE Injector detects the existence of an IEEE 802.3at device, the HPOE” LED indicator will be steady on.

Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is part of the shipping content. If the Declaration of Conformity is missing, you can request it by post under the below mentioned manufacturer address.

Product Compliance

www.assmann.com

Assmann Electronic GmbH Auf dem Schuffel 3 58513 Liidenscheid Germany