Overview
Industrial Ethernet switch with 8-Port 10/100Mbps RJ45 + 100Mbps / 1000Mbps base-FX, the Product meet CE, RoHS standards. Switch has the operating temperature of -40°C ~ 80°C, has the super firmness can adapt to all kinds of harsh environment, can also be conveniently placed in the compact space of the control box. The installation characteristics of the guide rail, wide temperature operation, IP40 protection class housing and LED indicator light make the switch a plug and play industrial grade device, providing a reliable and convenient solution for users to network their Ethernet devices.
Features
- The use of high quality photoelectric integration module to provide good optical and electrical characteristics
- Ensure reliable data transmission and long working life
- Support full duplex or half duplex mode, with automatic negotiation capability
- Network port support automatic cross identification
- Internal storage and forwarding mechanism, support a variety of protocols
- In line with industrial operating standards, the average trouble-free work in more than 300,000 hours
- Working power supply:
DN-651132/DN-651146: DC 12-48V
DN-651133/DN-651147 (PoE): DC 48-57V
Specification
Standard:
IEEE802.3i 10Base-T ; IEEE802.3u; 100Base-TX/FX
Interface:
8-Port 10/100Mbps RJ45+1 Port 100Mbps Base-FX Industrial Switch
8-Port 10/100Mbps RJ45+2 Port 1000Mbps Base-FX Industrial Switch
Work environment:
Working: -40 ~ 80 °C,
Storage: -40 ~ 80 °C
Power supply:
Input voltage: DC12-48V (two-way power redundancy backup)
Input voltage: DC48-57V for Poe version
Access terminal: terminal block;
Support dual power redundancy;
Support built-in over current 4.0A protection;
Support reverse connection protection
Mechanical characteristic:
IP40 aluminum housing
DIN rail install
Natural cooling, no fan
Industrial standard:
FCC Part 15 Subpart B, EN55032, Class A
IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air)
IEC61000-4-3 (RS): 10V/m (80~1000MHz)
IEC61000-4-4 (EFT): Power Port: ±2kV; Data Port: ±1kV
IEC61000-4-5 (Surge): Power Port: ±2kV/CM, ±1kV/DC;
Data Port: ±4Kv/ CM, ±42Kv/ DM
IEC61000-4-6 (CS): 3V (10 kHz-150 kHz); 10V (150 kHz-80 MHz)
IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s)
Frequency range: 150kHz-80MHz
Impact: IEC60068-2-27
Free Fall: IEC60068-2-32
Vibration: IEC60068-2-6
Spec table:
Model No | DN-651132 | DN-651133 |
---|---|---|
Network port | 8x 100Mbps | 8x 100Mbps |
SFP slot | 1x 100Mbps | 1x 100Mbps |
PoE Spec. | NA | IEEE802.3af/IEEE802.3at |
Power Pin Assignment | NA | 1/2+;3/6- |
Bandwidth | 1.8G | 1.8G |
Packet Buffer Memory | 1.25Mbit | 1.25Mbit |
Forwarding rate | 1.4Mpps | 1.4Mpps |
Mac address table | 2K | 2K |
Max. Frame Size | 9000bytes | 9000bytes |
Power consumption | < 8 watts | < 8 watts(excluded PoE) |
Surge protection | 4KV | 4KV |
Enclosure | IP40 | IP40 |
Power Supply | DC12-48V | DC48-57V |
MTBF | 300,000 hours | 300,000 hours |
Working Temp. | -40 to 80C | -40 to 80C |
Model No | DN-651146 | DN-651147 |
Network port | 8x 100Mbps | 8x 100Mbps |
SFP slot | 2x 1000Mpbs | 2x 1000Mpbs |
PoE Spec. | NA | IEEE802.3af/IEEE802.3at |
Power Pin Assignment | NA | 1/2+;3/6- |
Bandwidth | 5.6Gbps | 5.6Gbps |
Packet Buffer Memory | 1.2Mbit | 1.2Mbit |
Forwarding rate | 4.2Mpps | 4.2Mpps |
Mac address table | 2K | 2K |
Max. Frame Size | 9000bytes | 9000bytes |
Power consumption | < 8 watts | < 8 watts(excluded PoE) |
Surge protection | 4KV | 4KV |
Enclosure | IP40 | IP40 |
Power Supply | DC12-48V | DC48-57V |
MTBF | 300,000 hours | 300,000 hours |
Working Temp. | -40 to 80C | -40 to 80C |
Packages
- Industrial switch 1pcs
- User manual 1pcs
Switch Panel
Side panel: P1 and P2 are the number of connecting terminals, P+1 and
P-1 are respectively to the positive and negative poles to be connected;
Earthing screw, used for Earthing equipment.
Front panel: The orange light on the port is the LINK light, which is on
when the connection is established and the data transmission is flashing.
The green light is PoE light, which is only on when the switch port is
supplying power to the PD devices (Only DN-651133/DN-651147 support PoE);
Power indicator light is on when connecting with Power
Switch size (mm)
Interface Definition
10/100Base-TX Ethernet interface:
This series of switches provides MDI/MDI-X self-identification with cable
support on all 10/100Basc-TX ports. In use, the Ethernet port of the switch
can be connected with other Ethernet terminal devices through network cables
(direct or cross). Please use Class 5 shielded twisted pair. The Ethernet port
pin definition is shown in the following figure:
RJ45 port supports automatic MDI/MDI-X operation, you can use a straight line
to connect to the PC or server, connect to other switches or hubs. In the
through line (MDI), pins 1, 2, 3, 4, 5, 6, 7, 8 correspond to the connection;
For the MDI-X port of a switch or hub, cross lines are used: 1-3, 2-6, 3-1, 6-2, 4-7, 5-8, 7-4, 8-5.10Base-T/100Base-T (X) pins are defined as follows:
Pin No. | MDI signal | MDI-X signal |
---|---|---|
1 | TX+ | RX+ |
2 | TX- | RX- |
3 | RX+ | TX+ |
6 | RX- | TX- |
4,5,7,8 | – | – |
Note: “Tx ±” refers to send data ±, “Rx ±” refers to received data ±, and “-” refers to unused data.
100base-FX / 1000base-FX Ethernet interface
This device provides 100Base-FX or 1000Base-FX SFP slot.
Patch cord classification
According to the transmission mode of light in the fiber, it can be divided
into multi-mode fiber and single-mode fiber. Multimode fiber has a thick glass
core (50 or 62.5μm), which can transmit light in various modes. However, the
high inter-mode dispersion limits the frequency at which digital signals can
be transmitted, so multimode fibers can be transmitted over relatively close
distances (typically only a few kilometers).
The single mode fiber has a very thin glass core (core diameter, usually 9 or 10μm) and can transmit only one mode of light. Therefore, it’s inter – module dispersion is very small, and it is suitable for remote communication. Under normal circumstances, the skin is orange for multi-mode, yellow for single mode.
Patch cord overview
LC to LC patch cord
LED Indicator
LED indicator | Status | Definition |
---|---|---|
Power | LED on | Power supplying informal |
LED off | Power supply abnormal or no powering | |
RJ45 indicator | Yellow LED on | Network connection informal |
Yellow LED flashing | Link communication informal | |
Green LED on | PoE feeding in normal | |
Yellow/Green LED off | No connection at port | |
LINK | Green flashing | Optical work in normal |
ACT | Green flashing | Switch work in normal |
Installation caution
Installation precautions
In order to avoid damage to equipment and personal injury caused by improper
use, please follow the following precautions:
- In order to avoid damage caused by falling of the equipment, please put the equipment in a stable environment.
- When supplying power to the equipment, pay attention to confirm the range of power supply voltage, as well as the positive and negative poles of the power supply, so as not to damage the equipment by wrong operation.
- In order to reduce the risk of electric shock, ensure that the equipment is well grounded in the working environment.
- No matter when, please do not arbitrarily remove the equipment shell.
- When placing the switch, please avoid the area with dust and strong electromagnetic interference
Din rail installation:
The first step is to check the grounding and stability of the guide rail: the guide rail slot of the switch is clamped into the guide rail; The second step: from the center to both sides of the guide rail positioning screws in order. Step 3: Use screws to fix the mounting rail card slot on the fixed guide groove at both ends of the guide rail to ensure that the guide rail and the switch are fixed on the guide rail vertically and stably.
grounding
Fix the grounding wire to the grounding screw above the switch and ensure good reliable connection of the grounding system.
Power Connection
Insert the power cord into the specified position of the 6-core terminal and
insert the terminal into the standard power supply inlet (P+1 and P-1 input
corresponding to the first power supply P1, and P+2 and P-2 input
corresponding to the second power supply P2). The available voltage standard
of the power supply is supported from 12VDC to 48VDC
This is a Class A product. In home environment, this product may cause radio
interference. In this case, the user may be required to take appropriate
measures.
Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is
part of the shipping content. If the Declaration of Conformity is missing, you
can request it by post under the below mentioned manufacturer address.
www.assmann.com
Gassmann Electronic GmbH Auf dem Scuffle 3, 58513 Ludenscheid Germany.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>