DIGITUS DN-953 Desktop Gigabit Switch Installation Guide
- October 30, 2023
- DIGITUS
Table of Contents
8 Port Gigabit PoE Switch,
19 Inch, Unmanaged,
2 SFP Uplink
Quick
Installation Guide
DN-95341-1
Introduction
The DIGITUS 8-Port Gigabit Rack mount Switch with eight Power over Ethernet
ports and two additional SFP Fiber Port, offers your network significant
improvement in terms of performance and efficiency. Thanks to PoE support, you
only need a single
(network) cable for power and data transfer. This switch makes it much easier
to connect devices such as access points, network cameras, and IP telephones,
and requires far less cabling than alternatives. It also allows you to extend
your network in places where there are no power supply cables or sockets
available. The switch does not require any configuration and therefore
guarantees quick and seamless integration into the network. Moreover, the
switch has a rack mountable design and can be easily installed with many
standard racks, which makes this device the perfect solution for data center
and local server rooms.
Features
- 8-Port 10/100/1000 Mbps PoE Gigabit rack mountable Switch + 2x SFP Uplink
- Ethernet IEEE802.3 / 802.3u / 802.3x/802.3ab/802.3z / IEEE802.3 af/at
- Power over Ethernet (PoE) – You only need one cable for power and data transfer
- PoE power budget: 140 Watts
- Supports PoE: Provides 8 PoE Port, each port output 30W maximum power
- No configuration necessary
- Status LEDs on each port
- Pin Feet: V+ (RJ45 Pin 3, 6) V- (RJ45 Pin 1, 2)
- Backplane: 20Gbps
- MAC address table: 4K
- Rack mountable in system rack (1U)
- Internal power supply: 150W
- Dimensions (L x W x H): 275 mm x 200 mm x 44 mm
- Weight: 4500g
- Ethernet speed: Gigabit
- Number of ports (uplink): 2
- Connection of uplink port: SFP
- VLAN: no
- PoE standard: IEEE802.3at (PoE+
Package Contents
- 8P POE switch 2 SFP Uplink Ports
- User Manual
- Power Cable
- Rubber feet 4pcs
- Mounting brackets 2pcs
- Screws 6pcs
Specifications
Fixed port | 8 x 10/100/1000Mbps PoE ports and 2 Gigabit SFP Ports |
---|---|
Standards and protocols | IEEE802.3 10Base-T Ethernet standard IEEE802.3u |
100Base-TX Fast Ethernet standard IEEE802.3ab 1000Base-T Ethernet standard
IEEE802.3z Gigabit Ethernet (fiber) IEEE802.3x Full duplex flow control and
Backpressure Half duplex flow control IEEE802.3ab Link aggregation
Forwarding Rate| 10/100/1000Mbps
LED Indicators| Power, Link/Act, PoE
AC Input Voltage Range| 100V-240V AC, 50/60Hz
Operating temperature| 0°C – 40°C
Storage temperature| -10°C – 70°C
Operating humidity| 5%-95% (non-condensing)
Exchange capacity| 20G
MAC Addresses| 4K
Power Supply| 150W
Power Consumption| 10W
PoE Technology
PoE Compliance| 100% IEEE 802.3af, 802.3at compliant
PoE Classification| PSE (Power Sourcing Equipment)
PoE Voltage| +52 VDC
PoE Power Budget| 140W
PoE Power| Up to 30 W per port
PoE Operation| Automatic detection and power management
PoE Pin Assignments| V+ (RJ45 Pin 3, 6), V- (RJ45 Pin 1, 2)
PoE Disconnect Mode| DC disconnect
Mechanical
Casing| Metal
Dimensions (W x L x H)| 275mm x 200mm x 44 mm
Installation| Rack mounting or Desktop
External Component Description
Front Panel
The front panel consists of LED indications and network ports.
PWR LED: The Power LED lights up when the Switch is connected to a power
source.
Link/Act LED: The Link/Act LED flashes which indicates a network link through
the corresponding port. Blinking indicates that the Switch is either sending
or receiving data to the port.
PoE indicator: constant brightness indicates that the PD device is connected
to the corresponding port, and extinguished indicates that the port is not
powered or no PD device is found.
Real Panel
The rear panel view of the Switch consists of an AC power connector.
Power outlet: Supports input voltages 100-240VAC, 50/60Hz.
Switch: Used to connect the power supply.
Fuse: Prevent affect the power grid from equipment short circuit.
(Tank containing a spare fuse)
Grounding: use specialized ground lead connect.
Hardware installation
6.1 switch installation
For safe switch installation and operation, it is recommended that you:
- Visually inspect the power cord to see that it is secured fully to the AC power connector
- Make sure that there is proper heat dissipation and adequate ventilation around the switch.
- Do not place heavy objects on the switch.
Desktop or Shelf Installation
When installing the switch on a desktop or shelf, the rubber feet included
with the device must be attached on the bottom at each corner of the device’s
base. Allow enough ventilation space between the device and the objects around
it.
Rack Installation
The switch can be mounted in an EIA standard size 19-inch rack, which can be
placed in a wiring closet with other equipment. To install, attach the
mounting brackets to the switch’s side panels (one on each side) and secure
them with the screws provided (please note that these brackets are not
designed for palm size switches).
Then, use the screws provided with the equipment rack to mount the switch in the rack.
6.2 Plugging in the AC Power Cord
You can connect AC power supply cord to switch back and the other side connect
the power outlet. (Power outlet might as well grounding and support over
voltage protection)
Warning: Do not turn on the power switch before power cables are
connected.
Power surge may cause damage to the Switch.
Power failure
As a precaution, the switch should be unplugged in case of power failure. When
power is resumed, plug the switch back in.
Network connection
CE Mark Warning : This is a Class A product. In home environment, this product may cause radio interference. In this case, the user may be required to take appropriate measures.