DIGITUS DN-65 Industrial Railmount Gigabit Switch Installation Guide
- March 13, 2024
- DIGITUS
Table of Contents
16-port 10/100/1000Base-TX
+2x Gigabit SFP Industrial
Ethernet Switch Quick Installation Guide
DN-651138
Overview
Industrial Ethernet switch with 16-Port 10/100/1000Mbps Base-TX and 2-Port
Gigabit SFP, the Product meet CE, FCC, RoHS standards.
DN-651138 switch has the operating temperature of -40°C ~ 80°C, has the super
firmness can adapt to all kinds of harsh environment, can also be conveniently
placed in the compact space of the control box. The installation
characteristics of the guide rail, wide temperature operation, IP40 protection
class housing and LED indicator light make the DN-651138 a plug and play
industrial grade device, providing a reliable and convenient solution for
users to network their Ethernet devices.
Switch Panel
Side panel: P1 and P2 are the number of connecting terminals, and F is
the interface of alarm. P+1 and P-1 are respectively to the positive and
negative poles to be connected; Earthing screw, used for earthing equipment.
Front panel: The Yellow LED on the port is the LINK light, which is on
when the connection is established and the data transmission is flashing.
The green LED is POE light, which is only on when the switch port is supplying
power to PD device (this model is not to support PoE); Power indicator light
is on when connecting with Power.
Switch size (mm)
Features
- Support long range transmission by fiber optical port.
- Full working temp. -40 ~ 80 °C to ensure reliable data and long working life
- In line with industrial operating standards, the average trouble-free work in more than 300,000 hours dual power input
- Lightning Surge Protection (Power): 5000A (8/20μs)
- DIN Rail and Wall mount support
- Support full duplex or half duplex mode, with automatic negotiation capability
- Network port support automatic cross identification internal storage and forwarding mechanism
Specification
4.1 Standard:
IEEE802.310Base-T; IEEE802.3i 10Base-T; IEEE802.3u 100Base-TX/FX;
IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x
4.2 Interface:
16-Port RJ45; 2- Port SFP Uplink
4.3 Work environment:
Working: -40 ~ 80 °C
Storage: -40 ~ 80 °C
Relative Humidity: 5%~95 %
(No condensation)
4. 4 Switch:
Bandwidth: 56Gbps
Packet Buffer Memory: 4.1Mbit
Packet Forwarding Rate: 42Mpps
MAC Address Table: 8K
4.5 Power supply:
Input voltage: DC12-52V (two-way power redundancy backup)
Access terminal: terminal block;
Support dual power redundancy
Support built-in over current 4.0A protection
Support reverse connection protection
4.6 Mechanical characteristic:
IP40 aluminum housing
DIN rail install
Natural cooling, no fan
Weight: 1.0Kg
Measurement: 175.6 x 135 x 45.5 mm
4.7 Industrial standard:
FCC Part 15 Subpart B, EN55032, Class A
IEC61000-4-2 (ESD): ±8kV (contact), ±12kV (air)
IEC61000-4-3 (RS): 10V/m (80~1000MHz)
IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port: ±2kV
IEC61000-4-5 (Surge): Power Port: ±2kV/DM, ±4kV/CM;
Data Port: ±2kV
IEC61000-4-6 (CS): 3V (10 kHz-150 kHz); 10V (150 kHz-80MHz)
IEC61000-4-16 (Common mode conduction): 30V (cont.), 300V (1s)
Frequency range: 150kHz-80MHz
Impact: IEC60068-2-27
Free Fall: IEC60068-2-32
Vibration: IEC60068-2-6
Interface Definition
5.1 10/100/1000Base-TX Ethernet interface:
This switch provides MDI/MDI-X self-identification with cable support on all
10/100/1000Base-TX ports. In use, the Ethernet port of the switch can be
connected with other Ethernet terminal devices through network cables (direct
or cross). Please use Class 5 shielded twisted pair. The Ethernet port pin
definition is shown in the following figure: RJ45 port supports automatic
MDI/MDI-X operation, you can use a straight line to connect to the PC or
server, connect to other switches or hubs. In the through line (MDI), pins 1,
2, 3, 4, 5, 6, 7, 8 correspond to the connection;
For the MDI-X port of a switch or hub, cross lines are used: 1-3, 2-6, 3-1,
6-2, 4-7, 5-8, 7-4, 8-5.10Base-T/100Base-T (X) pins are defined as follows:
Pin No. | MDI signal | MDI-X signal |
---|---|---|
1 | TX+ | RX+ |
2 | TX- | RX- |
3 | RX+ | TX+ |
6 | RX- | TX- |
4,5,7,8 | – | – |
Note: “Tx ±” refers to send data, “Rx ±” refers to received data ±, and
“-” refers to unused data.
5.2 1000base-FX Ehernet interface
This device provides 1000Base single-mode dualfiber SC module, and multi-mode
like LC, ST as optional.
5.2.1 Patch cord classification
According to the transmission mode of light in the fiber, it can be divided
into multi-mode fiber and single-mode fiber. Multimode fiber has a thick glass
core (50 or 62.5μm), which can transmit light in various modes. However, the
high inter-mode dispersion limits the frequency at which digital signals can
be transmitted, so multimode fibers can be transmitted over relatively close
distances (typically only a few kilometers).
The single-mode fiber has a very thin glass core (core diameter, usually 9 or
10μm) and can transmit only one mode of light. Therefore, it ’s inter – module
dispersion is very small, and it is suitable for remote communication. Under
normal circumstances, the skin is orange for multi-mode, yellow for single
mode.
5.2.2 SFP module (Optional, not included)
LC connector, Gigabit, 20km Single mode, dual fiber (DN-81011) LC connector,
Gigabit, 20km Single mode, Single fiber (DN-81020 and DN-81021)
LED Indicator
LED indicator | Status | Definition |
---|---|---|
P1/P2 | Red LED on | Power supplying in normal |
Red LED off | Power supply abnormal or no powering | |
RJ45 indicator | Yellow LED on | Network connection in normal |
Yellow LED flashing | Link communication in normal | |
Yellow/Green LED off | No connection at port |
Note: this model is not available with PoE
Installation caution
7.1 Installation precautions
In order to avoid damage to equipment and personal injury caused by improper
use, please follow the following precautions:
- In order to avoid damage caused by falling of the equipment, please put the equipment in a stable environment.
- When supplying power to the equipment, pay attention to confirm the range of power supply voltage, as well as the positive and negative poles of the power supply, so as not to damage the equipment by wrong operation.
- In order to reduce the risk of electric shock, ensure that the equipment is well grounded in the working environment.
- No matter when, please do not arbitrarily remove the equipment shell.
- When placing the switch, please avoid the area with dust and strong electromagnetic interference
7.2 Din rail installation:
The first step is to check the grounding and stability of the guide rail: the
guide rail slot of the switch is clamped into the guide rail; The second step:
from the center to both sides of the guide rail positioning screws in order.
Step 3: Use screws to fix the mounting rail card slot on the fixed guide
groove at both ends of the guide rail to ensure that the guide rail and the
switch are fixed on the guide rail vertically and stably.
7.3 grounding Fix the grounding wire to the grounding screw above the
switch, and ensure good reliable connection of the grounding system.
7.4 Power Connection
Insert the power cord into the specified position of the 6-core terminal, and
insert the terminal into the standard power supply inlet (P+1 and P-1 input
corresponding to the first power supply P1, and P+2 and P-2 input
corresponding to the second power supply P2). The available voltage standard
of the power supply is supported from 12VDC to 52VDC
Packages
Content | QTY |
---|---|
Industrial switch | 1 PCS |
Quick installation guide | 1 PCS |
Rackmount kit | 1 SET |
Terminal block | 1 PCS |
This is a Class A product. In home environment, this product may cause radio
interference. In this case, the user may be required to take appropriate
measures.
Hereby Assmann Electronic GmbH, declares that the Declaration of Conformity is
part of the shipping content. If the Declaration of Conformity is missing, you
can request it by post under the below mentioned manufacturer address.
www.assmann.com
Assmann Electronic GmbH
Auf dem Schüffel 3
58513 Lüdenscheid,
Germany
Documents / Resources
|
DIGITUS DN-65 Industrial Railmount Gigabit
Switch
[pdf] Installation Guide
DN-65 Industrial Railmount Gigabit Switch, DN-65, Industrial Railmount Gigabit
Switch, Railmount Gigabit Switch, Gigabit Switch
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>