ACURITE 00415 Thermometer Instruction Manual
- June 6, 2024
- Acurite
Table of Contents
- SAVE THIS MANUAL FOR FUTURE REFERENCE.
- Unpacking Instructions
- Package Contents
- Features & Benefits
- SETUP
- Clock Setup
- Important Placement Guidelines
- Setup is Complete
- OPERATION
- Troubleshooting
- Care & Maintenance
- Specifications
- FCC Information
- Customer Support
- Limited One Year Warranty
- Documents / Resources
Thermometer
models 00415/00416/00417/00418/00420
Instruction Manual
Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display unit
- Outdoor sensor
- Instruction Manual
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection
www.AcuRite.com
Features & Benefits
DISPLAY UNIT
-
Sensor Low Battery Indicator
-
Current Outdoor Temperature
-
Clock
Displays time in either 12 hour or 24-hour formats. -
Current Indoor Temperature
-
°F/°C Button
Press to select degrees Fahrenheit or degrees Celsius. -
Set Button
For setup preferences. -
Wireless Sensor Signal Strength
-
Display Low Battery Indicator
-
MAX/MIN Button
Press to view high/low-temperature records. -
+ Button
For setup preferences.
OUTDOOR SENSOR -
Integrated Hanger
For easy placement. -
Wireless Signal Indicator
Flashes when data is being sent to the display unit. -
Battery Compartment Cover
SETUP
Install or Replace Batteries
AcuRite recommends high-quality alkaline batteries for the best product
performance. Heavy duty or rechargeable batteries are not recommended.
The outdoor sensor requires lithium batteries in low-temperature conditions.
Cold temperatures can cause alkaline batteries to function improperly. Use
lithium batteries in the outdoor sensor for temperatures below -4ºF / -20ºC.
Outdoor Sensor
- Slide off the battery compartment cover.
- Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
- Replace the battery cover.
Display Unit
- Slide off the battery compartment cover.
- Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
- Replace the battery cover.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device
prior to battery installation. Remove batteries from equipment that is not to
be used for an extended period of time. Follow the polarity (+/-) diagram in
the battery compartment. Promptly remove dead batteries from the device.
Dispose of used batteries properly. Only batteries of the same or equivalent
type as recommended are to be used. DO NOT incinerate used batteries. DO NOT
dispose of batteries in free, as batteries may explode or leak. DO NOT mix old
and new batteries or types of batteries (alkaline/standard). DO NOT use
rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT
short-circuit the supply terminals.
Clock Setup
Press and hold the “SET” button for 3 seconds to enter the SET MODE. Once
inset mode, the preference you are currently setting will blink on the
display.
To adjust the currently selected (flashing) preference item, press the “+”
button (press and HOLD to fast adjust).
To save your adjustments, press and release the “SET” button again to adjust
the next preference.
The preference set order is as follows:
CLOCK HOUR MODE (12 hours or 24 hours)
CLOCK HOUR
CLOCK MINUTE
You will automatically exit SET MODE if no buttons are pressed for 30 seconds.
Enter basic setup mode at any time by pressing and holding the “SET” button
for 3 seconds.
Select Degrees Fahrenheit or Celsius
To select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units,
press the “ ºF/ºC ” button located on the front of the display unit.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display unit and outdoor sensor are critical to the
accuracy and performance of this product.
Display Unit Placement
Place the display unit in a dry area free of dirt and dust.
The display unit stands upright for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensors must be placed outside to observe outdoor conditions. The sensor is
water-resistant and is designed for general outdoor use, however, to extend
its life place the sensor in an area protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or by using string
(not included) to hang it from a suitable location, like a well-covered tree
branch. The best location is 4 to 8 feet above the ground with permanent shade
and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- The display unit and outdoor sensor must be within 165 ft (50 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
The sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.
OPERATION
Using the Thermometer
High/Low Records
Press the “MAX/MIN” button to view minimum and maximum outdoor and indoor
temperature records. The temperature records are automatically cleared daily
at midnight.
To view the MAXIMUM recorded outdoor and indoor temperature readings, press
and release the “MAX/MIN” button. The “MAX” icon appears on the display.
To manually clear the MAXIMUM recorded values, press and hold the “MAX/ MIN”
button while in the MAX view mode. Dashes display to confirm you have cleared
the MAXIMUM records.
To view, the MINIMUM recorded outdoor and indoor temperature readings, press
and release the “MAX/MIN” button until the “MIN” icon appears on the display.
To manually clear the MAXIMUM recorded values, press and hold the “MAX/ MIN”
button while in the MIN view mode. Dashes display to confirm you have cleared
the MINIMUM records.
Troubleshooting
No outdoor sensor reception Tull| If the wireless signal indicator shows no
bars:
• Relocate the display unit and/or the outdoor sensor.
The units must be within 165 ft (50 m) of each other.
• Make sure both units are placed at least 3 feet (.9 m) away from electronics
that may interfere with the wireless communication (such as TVs, microwaves,
computers, etc).
• Use standard alkaline batteries (or lithium batteries in the sensor when the
temperature is below 4ºF/-20ºC). Do not use heavy-duty or rechargeable
batteries. NOTE: It may take up to 20 minutes for the display unit and sensor
to synchronize after batteries are replaced.
---|---
Outdoor temperature is flashing or showing dashes| Flashing of the outdoor
temperature is generally an indication of wireless interference.
1. Bring both the sensor and display unit indoors and remove at least one
battery from each.
2. Reinstall the battery in the outdoor sensor.
3. Reinstall the battery in the display unit.
4. Let the units sit within a couple of feet of each other for about 20
minutes to gain a strong connection.
Inaccurate temperature| • Make sure both the display unit and sensor are
placed out of direct sunlight and away from any heat sources or vents (see
page 6).
Display screen not working| • Check that the batteries are installed
correctly.
Batteries may need to be replaced.
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt, and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|
Indoor: 32°F to 122°F; 0°C to 50°C
WIRELESS RANGE| 165 ft / 50 m depending on home construction materials
WIRELESS FREQUENCY| 433 MHz
POWER| Display: 2 x AA alkaline batteries
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING| 30-second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
info@chaney-inst.com
24/7 support at www.AcuRite.com
- Installation Videos
- Instruction Manuals
- Replacement Parts
- Register your Product
- Support User Forum
- Submit Feedback & Ideas
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection
www.AcuRite.com
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures be of good material
and workmanship and to be free of defects when properly installed and operated
for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com
for the fastest way to register your product. However, product registration
does not eliminate the need to retain your original proof of purchase in order
to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures be of good
material and workmanship and to be free of defects when properly installed and
operated for a period of one year from the date of purchase. Remedy for
breach of this warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is proven to breach
the warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges. This warranty will not be breached, and
Chaney will give no credit for products it manufactures which have received
normal wear and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired or altered by
others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties,
express or implied, and all other warranties are hereby expressly disclaimed,
including without limitation the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose. Chaney expressly
disclaims all liability for special, consequential, or incidental damages,
whether arising in tort or by contract from any breach of this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. Chaney
further disclaims all liability from personal injury relating to its products
to the extent permitted by law. By acceptance of any of Chaney’s products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm, or corporation is authorized to assume for Chaney any
other liability in connection with the sale of its products. Furthermore, no
person, firm, or corporation is authorized to modify or waive the terms of
this paragraph, and the preceding paragraph, unless done in writing and signed
by a duly authorized agent of Chaney. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark
of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and
copyrights are the property of their respective owners. AcuRite uses patented
technology.
Visit www.AcuRite.com/patents for details.
Printed in China
00420 INST 041114
Documents / Resources
|
ACURITE 00415
Thermometer
[pdf] Instruction Manual
00415, 00416, 00417, 00418, 00420, 00415 Thermometer, Thermometer
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>