AcuRite 00829 Weather Forecast Station Instruction Manual
- June 1, 2024
- Acurite
Table of Contents
- AcuRite 00829 Weather Forecast Station
- Package Contents
- Features & Benefits
- SETUP
- Placement for Maximum Accuracy
- OPERATION
- Troubleshooting
- Care & Maintenance
- Specifications
- FCC Information
- Customer Support
- Limited One Year Warranty
- FREQUENTLY ASKED QUESTIONS
- VIDEO – PRODUCT OVERVIEW
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AcuRite 00829 Weather Forecast Station
Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
- Display unit with tabletop stand
- Outdoor sensor
- Instruction Manual
Features & Benefits
OUTDOOR SENSOR
- Integrated Hanger For easy placement.
- Wireless Signal Indicator Flashes when data is being sent to the display unit.
- Battery Compartment
- A-B-C Switch ID code that must match the display’s – B-C switch to ensure units synchronize.
- Battery Compartment Cover
DISPLAY UNIT
- Current Outdoor Temperature
- Heat index, Dew Point or Frost Point
- Display Unit Low Battery Indicator
- Current Indoor Temperature
- Auto or Manual Pressure Mode Indicates pressure mode preference; the arrow indicates direction the pressure is trending.
- Auto Pressure Mode Pressure will self-calibrate over a 14-day Learning Mode.
- Manual Pressure Mode Indicates raw pressure value, no adjustment for sea level (can be calibrated).
- Moon Phase
- DOWN Button for setup preferences.
- UP Button for setup preferences.
- SET Button for setup preferences.
- 12 to 24-Hour Weather Forecast Self-Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast.
- Learning Mode Icon Disappears after the weather forecast self-calibration is complete.
- Current Indoor Humidity
- Current Outdoor Humidity
- Outdoor Sensor Signal Strength
- Sensor Low Battery Indicator
- Date
- Intelli-Time® Clock Automatically updates itself for Daylight Saving Time.
SETUP
Sensor Setup
Set the A-B-C Switch
- The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.
Install or Replace Batteries
- AcuRite recommends high-quality alkaline or lithium batteries for the best product performance. Heavy-duty or rechargeable batteries are not recommended.
- The sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4ºF / -20ºC.
- Slide off the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment for part 2.
- Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
- Replace the battery cover.
Display Unit Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize. -
Install or Replace Batteries
1. Remove the battery compartment cover.
2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY:
- Clean the battery contacts and also those of the device prior to battery installation.
- Remove batteries from equipment which is not to be used for an extended period of time.
- Follow the polarity (+/-) diagram in the battery compartment.
- Promptly remove dead batteries from the device.
- Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used.
- DO NOT incinerate used batteries.
- DO NOT dispose of batteries in a fire, as batteries may explode or leak.
- DO NOT mix old and new batteries or types of batteries (alkaline/standard).
- DO NOT use rechargeable batteries.
- DO NOT recharge non-rechargeable batteries.
- DO NOT short-circuit the supply terminals.
Intelli-Time® Clock
- Intelli-Time products are pre-programmed with the correct time and date. Intelli-Time technology instructs the time and date to set themselves. All you need to do is select your Time Zone and Daylight Saving Time preferences. The clock will then automatically set itself and change for Daylight Saving Time.
Set the Time, Date & Units
- Press the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.
- To adjust the currently selected (flashing) item, press and release the “ ” or “ “ buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “ ” button again to adjust the next preference. The preference set order is as follows:
- TIME ZONE ( PST MST CST EST AST HAST AKST)
- DST (Daylight Saving Time ON or OFF)*
- CLOCK HOUR
- CLOCK MINUTE
- CALENDAR MONTH
- CALENDAR DATE
- CALENDAR YEAR
- TEMPERATURE UNITS (ºF or ºC)
- PRESSURE UNITS (inHg or hPa)
If you live in an area that observes Daylight Saving Time, DST should be set to ON. You will automatically exit SET MODE if no buttons are pressed for 30 seconds. Enter setup mode at any time by pressing the “ ” button.
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and outdoor sensor are critical to the accuracy and performance of this product.
Display Unit Placement
- Place the display unit in a dry area free of dirt and dust. The display unit stands upright for tabletop use or is wall-mountable.
Outdoor Sensor Placement
- Sensors must be placed outside to observe outdoor conditions. The sensor is water resistant and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements.
- Hang the sensor using the integrated hang holes or hanger, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- The display unit and outdoor sensor must be within 330 ft (100 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
- The sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.
OPERATION
Using the Weather Forecast Station
-
Learning Mode
Self-Calibrating Forecasting uses a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction. -
Weather Forecast
AcuRite’s patented Self-Calibrating Forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy – per-sonalized for your exact location.
View the complete list of icons at www.AcuRite.com/acurite- icons
-
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This weath-er station displays the current pressure with an arrow icon to indicate the direc-tion the pressure is trending (FALLING, STEADY, or RISING). -
Moon Phase
Track the phases of the moon, conveyed through simple lunar phase icons:
High & Low Records
- Today’s high and low records are recorded for indoor and outdoor temperature and humidity. To view the high records, press the “ ” button. To view low records, press the “ “ button. Records automatically clear at 12:00am midnight every day.
- To manually clear all of today’s LOW recorded values, press and hold the “ “ button for 2 seconds. Dashes display to confirm you have cleared the LOW records.
- To manually clear all of today’s HIGH recorded values, press and hold the “ ” button for 2 seconds. Dashes display to confirm you have cleared the HIGH records.
Troubleshooting
No outdoor sensor reception
no bars
| If the wireless signal indicator shows no bars:
• Relocate the display unit and/or the outdoor sensor. The units must be within 330 ft (100 m) of each other.
• Make sure both units are placed at least 3 feet (.9
m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
• Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4ºF/-20ºC). Do not use heavy duty or rechargeable batteries. NOTE: It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced.
---|---
Outdoor temperature is flashing or
showing dashes
| Flashing of the outdoor temperature is generally an indication of wireless interference.
1. Bring both the sensor and display unit indoors and remove at least one battery from each.
2. Make sure the A-B-C switch on both units match.
3. Reinstall the battery in the outdoor sensor.
4. Reinstall the battery in the display unit.
5. Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection.
Inaccurate forecast
| • Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.
• Has Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate.
• Allow unit to run continuously for 33 days. Battery removal or resetting the display unit will restart Learning Mode. After 14 days, forecast should be fairly accurate, however Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity
| • Make sure both the display unit and sensor are placed out of direct sunlight and away from any heat sources or vents (see page 7).
• Make sure both units are positioned away from moisture sources (see page 7).
Display screen not working
- Check that the batteries are installed correctly. Batteries may need to be replaced.
- Reset the display by pressing the reset button, located on the back of the display unit. Date and time will need to be entered after a reset.
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
-
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. -
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Calibration
Calibrate Temperature & Humidity
The indoor / outdoor temperature and humidity readings can be calibrated on the display unit to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact your data accuracy.
- To access calibration mode, press AND HOLD the “ ”, “ “, and “ ” buttons for at least 5 seconds.
- Once in calibration mode, the preference you are currently setting will blink on the display.
- Press the “ ” or “ “ buttons to calibrate the data value higher or lower from the actual reading.
- Press the “ ” button to confirm the calibration adjustment. The “ ” icon will remain illuminated next to calibrated values.
- The next adjustable data will begin flashing, indicating it is ready to be calibrated. Repeat Steps 1 – 4 to calibrate additional data.
After 20 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibrations will be erased if the display is reset or if batteries are removed.
Calibrate Barometric Pressure
The weather station default pressure mode is “AUTO”. In auto mode, the pressure will calibrate itself over a 14 day Learning Mode. Barometric pressure can be manually calibrated:
- Press AND HOLD the “ ” button for at least 10 seconds to enter manual pressure mode.
- The un-calibrated pressure will be displayed. Press AND HOLD the “ ”, “ “, and “ ” buttons for at least 5 seconds.
- Press the “ ” or “ “ buttons to calibrate the pressure higher or lower.
- Press the “ ” button to confirm the calibration adjustment. Note: The “ ” icon will remain illuminated next to the calibrated value.
After 20 seconds of inactivity, the display will save your adjustments and exit calibration mode. Note: Calibration will be erased if the display is reset or if batteries are removed. To exit manual pressure mode and return to auto mode press and hold the “ ” button for at least 10 seconds.
Replace Intelli-Time Battery
- This device comes with a factory installed “CR2032” coin-cell battery that powers the Intelli-Time memory.
- If the display unit sits without power for a long period of time, the coin-cell battery may need to be replaced to ensure the Intelli-Time feature functions properly.
- To replace the battery, remove small screw to gain access to the Intelli-Time battery compartment. Install battery with “+” positive terminal facing OUT.
WARNING: THIS PRODUCT CONTAINS A BUTTON-CELL BATTERY. IF SWALLOWED, IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2 HOURS. SEEK MEDICAL ATTENTION IMMEDIATELY IF INGESTED.
Specifications
TEMPERATURE RANGE | Outdoor: -40ºF to 158ºF; -40ºC to 70ºC |
---|
Indoor: 32ºF to 122ºF; 0ºC to 50ºC
HUMIDITY RANGE| 1% to 99% RH
WIRELESS RANGE| 330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY| 433 MHz
POWER| Display: 3 x AA alkaline batteries Sensor: 2 AA alkaline or
lithium batteries
DATA REPORTING| Outdoor: 16 second updates Indoor: 30 second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip-ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device..
Customer Support
AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: 877-221-1252 info@chaney- inst.com 24/7 support at www.AcuRite.com
- Installation Videos
- Instruction Manuals
- Replacement Parts
- Register your Product
- Support User Forum
- Submit Feedback & Ideas
Limited One Year Warranty
- At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures tobe of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.
- We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.
- Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.
- The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co. 965 Wells St., Lake Geneva, WI 53147
It’s more than accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copy-rights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.
FREQUENTLY ASKED QUESTIONS
What special feature does the AcuRite 00829 Weather Forecast Station offer?
The AcuRite 00829 Weather Forecast Station allows you to plan your day with confidence by generating a weather report right from your own backyard. It uses patented Self-Calibrating Technology to provide a personal forecast of 12 to 24-hour weather conditions.
What is the power source for the AcuRite 00829 Weather Forecast Station?
The AcuRite 00829 Weather Forecast Station is battery-powered, requiring 5 AA batteries for operation.
How many batteries does the AcuRite 00829 Weather Forecast Station require?
The AcuRite 00829 Weather Forecast Station requires 5 AA batteries for operation.
What are the dimensions of the AcuRite 00829 Weather Forecast Station?
The AcuRite 00829 Weather Forecast Station measures 2.13 inches in depth, 3.75 inches in width, and 6.25 inches in height.
What shape is the AcuRite 00829 Weather Forecast Station?
The AcuRite 00829 Weather Forecast Station is rectangular in shape.
What type of display does the AcuRite 00829 Weather Forecast Station have?
The AcuRite 00829 Weather Forecast Station features an LCD display for easy viewing.
How much does the AcuRite 00829 Weather Forecast Station weigh?
The AcuRite 00829 Weather Forecast Station weighs 8.8 ounces.
Who is the manufacturer of the AcuRite 00829 Weather Forecast Station?
The AcuRite 00829 Weather Forecast Station is manufactured by AcuRite.
What is the item model number of the AcuRite 00829 Weather Forecast Station?
The item model number of the AcuRite 00829 Weather Forecast Station is 00829.
What is the price of the AcuRite 00829 Weather Forecast Station?
The price of the AcuRite 00829 Weather Forecast Station is $42.00.
What is the warranty period for the AcuRite 00829 Weather Forecast Station?
The AcuRite 00829 Weather Forecast Station comes with a one-year warranty.
Why is my AcuRite 00829 Weather Forecast Station not displaying any weather information?
Check if the batteries are inserted correctly and if they have enough power. Also, ensure that the outdoor sensor is properly positioned and within the transmission range of the main unit.
The weather forecast on my AcuRite 00829 Weather Forecast Station seems inaccurate. How can I fix this?
Make sure the outdoor sensor is placed in an open area away from obstructions that may interfere with its readings, such as walls or trees. Additionally, try resetting the unit and allowing it to recalibrate.
Why is the LCD display on my AcuRite 00829 Weather Forecast Station not functioning properly?
Check if the batteries are low or if there is any damage to the display screen. If the issue persists, try replacing the batteries and resetting the unit.
My AcuRite 00829 Weather Forecast Station is not receiving data from the outdoor sensor. What should I do?
Ensure that the outdoor sensor is properly paired with the main unit and that they are on the same channel or frequency. You may need to reposition the sensor or main unit to improve signal reception.