saxby 81011 Icarus Pir 2LT Wall Instruction Manual
- June 6, 2024
- saxby
Table of Contents
Instruction manual
ICARUS PIR 2LT WALL
81011
Fitting/replacing bulbs: Max. 5W LED GU10
• This fitting has been designed to use energy-efficient LED bulbs. Ensure
that the minimum
distance to the illuminated surface is not less than 0.5m .
• When changing a bulb, always switch off at the mains and allow the bulb to
cool before handling. Dispose of used bulbs carefully. Do not exceed the
wattage stated or use a different shape bulb from that indicated on the
fitting. Use of the incorrect bulb will damage the product and invalidate the
guarantee.
PIR Adjustment
To access the adjustment screws flip down the black cover over the PIR sensor.
Take great care when adjusting the sensor screws, not to over tighten as they
can be easily broken.
• The unit must be installed in a vertical position and fitted 1.8-2.5m above
the ground.
• The PIR sensor can be adjusted, allowing the detection distance to be altered to suit the location. The detection angle is set at 110º. The duration that the lamp stays on can also be altered from 5 seconds – 5 minutes. The LUX range is 10-2000 lux. Use a small screwdriver to adjust the “TIME” and “SENS” screws. When adjusting the sensitivity detection distance) in daylight, it will be necessary to cover the sensor to simulate nighttime.
The PIR sensor has a manual override function which can be operated by
taking the following steps:
• When first switched on, the PIR sensor “warms up” for approx 1 minute and
then goes into AUTO mode.
• In AUTO mode, switch the power OFF and ON twice within 3 seconds, the PIR
sensor will switch to MANUAL mode. In MANUAL mode, the light will remain ON
permanently, without the PIR function. • To return to AUTO mode, switch the
power OFF and ON twice within 3 seconds.
• In either mode, if the power is switched OFF for more than 6 seconds, the
PIR sensor will go through the ‘warm up’ process again when you turn it on
next time.
Technical data
240 V~, 50 Hz
Supply Voltage: Bulb
Type: 2 x Max. 5W LED GU10
Conformity with all relevant EC Directive requirements.
The power supply is double insulated and does not require a connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or local store for recycling advice.
This product is rated at IP44.
This product is rated at IK05.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure the safe and satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require a connection to an
Earth circuit.
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting.
Ensure other persons cannot restore the electrical supply without your
knowledge.
If you are in any doubt, please consult a qualified electrician.
If replacing an existing fitting, make a careful note of the connections.
This light should be connected to a circuit with a 30mA RCD fitted.
This product is suitable for location in or near a marine environment.
The entire unit gets hot whilst on for a period of time, ensure the fitting is
mounted out of arms reach.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the junction box and each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and outdoor rated junction boxes (not supplied) away from areas where
they may be at risk of being cut, trapped, or damaged.
We recommend that you use the H05RN-F specification cable (not supplied) which
is an outdoor grade, rubber sheathed cable.
The mains supply cable must have a minimum cross-section area of 1.0mm2
.Cables must be protected using a suitable conduit or plastic trunking.
Installation
Existing fittings must be completely removed before the installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
Note that the switch is turned off before installation.
Ensure that the screws and cable entry points are sealed to maintain the IP
rating of the product.
After deciding the layout of the light fittings ensure that the cables are
long enough to connect to desired positions.
• Determine the position of your light fitting taking into account the entry
position of the cable and the ARROW indicating which WAY UP the base is to be
fitted. Make sure there is sufficient cable coming out of the wall to connect
to the terminal block. Ensure that the mounting surface is solid, preferably a
brick or block wall, and ensure that there are no other cables or pipes
beneath the surface.
• Diagram A. Fit the 2 threaded posts in the backplate and bring the main
cable through the rubber grommet then use the backplate as a template and mark
the 2 fixings holes, making sure the backplate is correctly aligned so that
the threaded bolts are horizontal. Use appropriate fixings to secure the
backplate to the wall. Ensuring the drain hole is at the base of the mounting
box.
• Diagram B. Connect the house wiring to the internal terminal block. The cable entry grommet must be securely in place to ensure that the water ingress protection is maintained. NOTE: This is a Class II fitting and must not be earthed. If you have any earth cables make sure that they are connected to each other – to maintain earth continuity throughout your property – and wrap the earth terminal and connections in 2 layers of good quality insulation tape and keep them away from the terminal connections of the fitting. Connect the incoming mains as per the diagram.
|
---|---
Wiring
Having correctly identified the wiring from your light fitting, connect to the
approved outdoor rated external terminal block in the following way: Check
that…
You have correctly identified the wires The connections are tight
No loose strands have been left out of the connection block Reseal the approved outdoor rated external terminal block
Commissioning
- Diagram C. Fit the terminal block onto the post in the backplate and then fit the front frame over the 2 threaded bolts in the backplate and secure with the 2 threaded nuts. Take care not to trap or strain the internal cables.
- Fit the appropriate bulbs into the lamp holders NOTE: Never fit bulbs of a higher wattage than specified on the label (as this may cause overheating and damage the fitting).
- Replace the bulb covers (1).
- Replace fuse or circuit breaker and switch on. Your light is now ready for use.