saxby lighting 103022 Batten Plug-In Pir Sensor Instruction Manual
- October 30, 2023
- saxby lighting
Table of Contents
BATTEN PLUG-IN PIR SENSOR
Instruction manual
103022
103023
103022 Batten Plug-In Pir Sensor
Thank you for purchasing this light fitting. Please read the instruction carefully before use to ensure safe and satisfactory operation of this product. Please retain these instruction for future reference.
INTRODUCTION
The miniature PIR (passive infrared) presence detector provides automatic
control of lighting loads. It is specifically designed for mounting onto a
batten style luminaire.
The detector will switch incandescent, fluorescent, compact fluorescent and
LED lighting.
The unit detects movement using a PIR sensor and turns the load on. When an
area is no longer occupied the load will switch off after a 10 minute time out
period.
A selection of fixing washers are supplied to aid fixing to a variety of
luminaires.
SPECIFICATIONS
Dimensions Supply Voltage Frequency Maximum Switching Load| See diagrams
opposite. 220-240VAC 50/60Hz 2 Amps fluorescent and incandescent lighting. 2
Amps compact fluorescent lighting. 2 Amps low energy lighting. 2 Amps low
voltage lighting (switch primary of transformer). Switch SON lighting loads
via a contactor.| Power consumption Cable specification
Temperature Humidity Material Type IP rating| On 799mW, Off 807mW 1m 1/1.13
solid core cable 105°C -10°C to 35°C 5 to 95% non-condensing Flame retardant
ABS/PC Class 2 IP65
---|---|---|---
DETECTION DIAGRAM
Note: illustration shows an average
of the walk across and walk towards figures below.
Walk across
Height | Range Diameter |
---|---|
7m | 16m |
2.8m | 9m |
Walk towards
Height | Range Diameter |
---|---|
7m | 10m |
2.8m | 5m |
INSTALLATION
Do not grip unit at the lens end. Hold the square body near the threaded end
when installing and tightening the nut. Care must be taken to prevent damage
to the lens and surrounding IP seal.
Components
| Part| Quantity Supplied
---|---|---
| Silicone washer| 2
| 5° washer| 1
| 5° spacer| 1
| M20 nut| 1
Mounting hole without key Mounting hole with key Note. Key to be at top of sensor.
IP LUMINAIRE FITTING
Note. Use the 5° spacers where the luminaire housing has a draft angle.
Important
Ensure that the Silicone washer and/or the IP spacer are used to ensure IP
rating.
SETTING BY REMOTE CONTROL
| | ON=Menual onsfter 6 hours turns to -AtfrOlnode
OFF=manual off, after 6 hours turns to “AUTO”mode| | The sensor starts to work
automatically,and all
paraments back the latest setting before TEST mode, onloff mode,and reset
mode.
---|---|---|---|---
| Time setting| | Reset
-Resetting of all functions
| Range setting| | In lest mode.hold time is only 2s. and stand-by time and
daylight sensor are disable.
Quit Test Mode,Press Auto button
| Preselected light values
-10 to 2000 Lux: Recommendation: rooms with daylight 500 Lux, without daylight 2000 Lux| | Permanent tamper protection
– Permanent inhibition or the detec -tor; only ON- and OFF function on the
remote control possible.
on=permanent on of apermanent off
Unlock permanent tamper prate:ion
| The latest surrounding lux value leamed,and Is set as the daylight
threshold.| |
Operation tips:
A:Set 10SEC,6M,100LUX as a exmple
- We push you set TIME, LUX, RANGE,it must enter in Auto mode first.
- Push ,the sensor off,sensor led will flash 3 times as confirmation.
- Push , the sensor off,sensor led will flash 3 times as confirmation.
- Push , the sensor off,sensor led will flash 3 times as confirmation.
B:ON MODE
If you push ON,the sensor on,and will enter in auto mode after 6 hours when
there are no motions.
C:OFF MODE
If you push off,the sensor on,and will enter in auto mode after 6 hours when
there are no motions.
NOTE: QUIT ON/OFF Mode,Please Auto Button.
D: LOCK(UNLOCK)
If you push , the remote control is lock,only ON and OFF function on the
remote control possible. In this time,sensor has no motion function,only
permanent on or permanent off. Push the ,unlock the remote control.
There is interval 4 seconds after the sensor stop work,during the 4 seconds,the sensor can’t work. After 4seconds, thEs ensor start work.
WIRING DIAGRAMS
INSTALLATION
The product is designed to be mounted directly to the outside of a
luminaire. The detector should be sited so that the occupants of the room fall
inside the detection pattern (shown opposite), at a recommended ceiling height
of 2.8m. Note that the lower the sensor is installed the smaller the detection
range will be, subject to the parameters shown on the detection diagram.
- Do not site within lm of forced air heating or ventilation..
- Do not fix to a vibrating surface.
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
www.saxbylighting.com