AC INFINITY AC-FBA10 Airblaze Fireplace Blower System User Manual
- June 4, 2024
- AC Infinity
Table of Contents
AC INFINITY AC-FBA10 Airblaze Fireplace Blower System
WELCOME
Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information.
KEY FEATURES
PRODUCT CONTENTS
AIRBLAZE FIREPLACE BLOWER SYSTEM (Included in all series)
MOUNTING
STEP 1
WARNING: Turn off the gas and electrical power before installing the kit!
While the fireplace is cool and off, remove the lower half of the fireplace
vent plate. Clean the inside of the area of any dust or dirt.
STEP 2
While very carefully placing the blower towards the rear, be sure the opening
of the fan in which the air blows out is facing up and the rubber feet are
facing the floor. Avoid any gas lines or electrical wires that are already in
place.
STEP 3
Be sure the metal plate is placed towards the wall of the vent and the rubber
feet are placed against the floor with the fan blades facing forward as
pictured in the illustration.
STEP 4
Be sure that the area you are mounting has no gas lines or electrical wires in
the way of the drilling area. Use a power drill to mount the fan in place with
the included screws to reduce any unwanted vibrations.
STEP 5
To mount the controller, position it on the outside of the vent away from the
fireplace and use the included screw sets. Use a drill to screw the controller
into place.
STEP 6
Once the fan and Universal Controller are securely mounted with in a safe
distance, you are now able to continue to power.
POWERING
STEP 1
The blower unit comes corded with a 4-pin molex connector. Locate the
connector and plug it into the bottom of the controller. Please make sure the
this cord is secured away from contacting the blower’s spinning impeller and
blades.
STEP 2
Plug in the thermal probe directly under the controller, the probe has to be
placed with in the same area as the blower underneath the fireplace. The probe
should be able to detect heat once the fire place is on to start the blower.
Please make sure the this cord is secured away from contacting the blower’s
spinning impeller and blades.
STEP 3
To power the device, plug the adapter pin into the Universal controller, and
the prong end into the outlet inside the fire place or outside the fireplace
if there are no outlets.
STEP 4
Follow the instructions starting on page 13 to program the controller. When
the sensor probe detects a temperature or humidity that exceeds your settings,
the blower will starting moving air. This accelerates air being moved from the
bottom of the fireplace vents, through the fire place, and exhausting out the
top. The heated air that the fireplace created will circulate back into the
room at a faster face and warm up a larger area.
PROGRAMMING
-
MODE BUTTON
This button cycles through each of the controller’s modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings). -
UP / DOWN BUTTON
The up and down buttons adjusts the settings of the mode that you are in. Up button increases and down button decreases. -
LEAF BUTTON
This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display. -
PROBE TEMP.
Displays the current tempera-ture that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in. -
CONTROLLER MODE
This area displays the mode that the controller is currently in. Press the Mode Button to cycle through the modes. -
ALERT ICONS
This area displays the alerts and statuses from the controller including alarms and screen lock. -
PROBE HUMIDITY
Displays the current humidity that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in. -
FAN SPEED
Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in. -
SETTING
Displays the value you have set for the current mode. Press the up or down button to change.
MODE SETTING
Press the Mode button to cycle through the controller’s available programming
modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers),
ALARM Settings (4 settings).
ON MODE
In this mode, the fans will run continuously regardless of temperature or
humidity. The speed set in this mode will be the max speed the fans can reach
in AUTO Mode.
OFF MODE
In this mode, the fans will not run regardless of temperature or humidity.
While in this mode, pressing the up or down button will change the display’s
brightness. Holding up or down button will change the display’s units F or C.
TIMER MODE
In this mode, press the up or down button to set a time for the timer. The
fans will run at the speed set in ON Mode until the timer’s clock runs out, in
which the fans will stop running. The clock will begin counting down if no
buttons are pressed for 3 seconds. Leaving the timer mode while the countdown
is running will pause the clock until you return to this mode.
AUTO MODE: HIGH TEMP.
In this mode, press the up or down button to set a high temperature trigger.
The fans will activate if the probe’s measured temperature exceeds the tem-
perature you have set in this mode. The activated fans will slowly increase in
speed until it reaches the speed set in ON Mode. Whenever the measured
temperature falls below your set temperature, the fans will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger, in which the digits under settings
will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even
if you are viewing a different trigger within AUTO Mode.
AUTO MODE: LOW TEMP.
In this mode, press the up or down button to set a low temperature trigger.
The fans will activate if the probe’s measured temperature falls below the
temperature you have set in this mode. The activated fans will slowly increase
in speed until it reaches the speed set in ON Mode. Whenever the measured
temperature rises above your set temperature, the fans will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger, in which the digits under settings
will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even
if you are viewing a different trigger within AUTO Mode.
AUTO MODE: HIGH HUMID.
In this mode, press the up or down button to set a high humidity trigger. The
fans will activate if the probe’s measured humidity exceeds the humidity you
have set in this mode. The activated fans will slowly increase in speed until
it reaches the speed set in ON Mode. Whenever the measured humidity falls
below your set humidity, the fans will slowly decrease in speed until the fans
stop. You may also hold the up and down button simultaneously to turn off this
trigger, in which the digits under settings will show OFF.
Note t hat this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
AUTO MODE: LOW HUMID.
In this mode, press the up or down button to set a low humidity trigger. The
fans will activate if the probe’s measured humidity falls below the humidity
you have set in this mode. The activated fans will slowly increase in speed
until it reaches the speed set in ON Mode. Whenever the measured humidity
rises above your set temperature, the fans will slowly decrease in speed until
the fans stop. You may also hold the up and down button simultaneously to turn
off this trigger, in which the digits under settings will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
ALARM SETTING: HIGH TEMP.
In this settings mode, press the up and down button to set a high temperature
alarm. The alarm will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. When the alarm triggers, the fan will
start spinning gradually to max speed regardless of your other settings. You
may also hold the up and down button simultaneously to turn off this alarm, in
which the digits under settings will show OFF.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: LOW TEMP.
In this settings mode, press the up and down button to set a low temperature
alarm. The alarm will activate if the probe’s measured tem-perature falls
below the temperature you have set in this mode. When the alarm triggers, the
fan will start spinning gradually to max speed regardless of your other
settings. You may also hold the up and down button simultaneously to turn off
this alarm, in which the digits under settings will show OFF.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: HIGH HUMID.
In this settings mode, press the up and down button to set a high humidity
alarm. The alarm will activate if the probe’s measured humidity exceeds the
humidity you have set in this mode. When the alarm triggers, the fan will
start spinning gradually to max speed regard-less of your other settings. You
may also hold the up and down button simultaneously to turn off this alarm, in
which the digits under settings will show OFF.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: LOW HUMID.
In this settings mode, press the up and down button to set a low temperature
alarm. The alarm will activate if the probe’s measured tem-perature falls
below the temperature you have set in this mode. When the alarm triggers, the
fan will start spinning gradually to max speed regardless of your other
settings. You may also hold the up and down button simultaneously to turn off
this alarm, in which the digits under settings will show OFF.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, please set the
controller to OFF Mode, then hold the up button for Fahrenheit (°F) or hold
the down button for Celsius (°C).
DISPLAY BRIGHTNESS
To adjust the brightness of the display, please set the controller to OFF
Mode, then press the up or down button to increase or decrease the brightness
level. Three brightness settings are available.
TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, please press the
MODE and UP button simultaneously. This can be done while the controller is
any mode or setting. The calibration cycle ranges from -8°F to 8°F (or -4°C to
4°C) and will be applied to the probe sensor’s measure-ments.
HUMIDITY CALIBRATION
To adjust the humidity that the probe sensor is measuring, please press the
MODE and DOWN button simultaneously. This can be done while the controller is
any mode or setting. The calibration cycle ranges from -8% to 8% and will be
applied to the probe sensor’s measurements.
CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidentally, hold
the LEAF button for two or more seconds. While the display is locked, you will
not be able to switch modes or changes any settings. You will only be able to
put the controller in ECO display by pressing the LEAF button. Holding the
LEAF button for two or more seconds will unlock the controller.
ECO-MODE
The controller can be put into ECO display in which the screen will be turned
off but all programs, settings, and alarms will be running in the background.
This can be done by pressing the LEAF button. You may also do this while the
controller is locked. To exit ECO display, simply press any buttons.
ALERT ICONS
On the top left of the display is the alert icon section. Icons may flash when
the controller wishes to alert you that a particular function or alarm is
being triggered.
AC INFINITY PRODUCTS
Register Booster Fans
The AIRTAP series is a line of register booster fans designed to quietly
increase airflow coming from your central heat and air conditioning systems,
increasing comfort for your home. Features a thermal controller with
intelligent programming that will automatically adjust airflow strength in
response to heating and cooling temperatures you have set.
Duct Fans
The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV
rooms and closets, as well as various DIY air circulation and exhaust
projects. Features a thermal controller with intelligent programming that will
automatically adjust duct fan speeds in re-sponse to changing temperatures.
Crawlspace Fans
The AIRTITAN is a line of weather-proof fans designed to provide ventilation,
odor, and moisture control for crawl spaces and basements. It features a
digital controller with intelligent programming that will adjust airflow
strength in response to high and low temperatures, as well as humidity.
WARRANTY
This warranty program is our commitment to you, the original purchaser, that each product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues.
The warranty program applies to any order, purchase, receipt, or use of any products from AC Infinity. The program covers products that have become defective, malfunctioned, or expressively if the product becomes unusable. The warranty program goes into effect on the date of purchase. The program will expire two years from the date of purchase. If your product becomes defective during that period, AC Infinity will replace your product with a new one or issue you a full refund.
The warranty program does not cover abuse or misuse. This includes physical damage, submersion of the product in water, incorrect Installation such as wrong voltage input, and misuse for any reason other than intended purposes. AC Infinity is not responsible for consequential loss or incidental damages of any nature caused by the product. We will not warrant damage from normal wear such as scratches and dings.
If you are not 100% satisfied with this product, we will be happy to replace it or issue you a full refund. Please contact us!
COPYRIGHT © 2018 AC INFINITY INC. ALL RIGHTS RESERVED
No part of the materials including graphics or logos available in this booklet
may be copied, photocopied, reproduced, translated or reduced to any
electronic medium or machine-readable form, in whole or in part, without
specific permission from AC Infinity Inc.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>