TELTONIKA FMB640 Professional GPS Tracker User Manual
- June 6, 2024
- teltonika
Table of Contents
- TELTONIKA FMB640 Professional GPS Tracker
- Know your device
- Pinout
- Wiring scheme
- Set up your device
- Quick SMS configuration
- Mounting recommendations
- LED indications
- Characteristics
- Electrical characteristics
- Safety information
- Certification and Approvals
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TELTONIKA FMB640 Professional GPS Tracker
Know your device
Pinout
PIN NUMBER | PIN NAME | DESCRIPTION |
---|---|---|
1 | GND (-) | Ground |
2 | CAN 1L | SAE J1939 CAN interface Low channel 1 |
3
| 1WIRE POWER|
Power supply pin for Dallas 1-Wire® devices
4| DIN4| Digital input, channel 4
5| DIN2| Digital input, channel 2
6| CAN 2L| SAE J1939 CAN interface Low channel 2
7| AIN2| Analog input, channel 2. Input range: 0-30V/0-10V DC
8| DOUT3| Digital output. Open collector output
9| DOUT2| Digital output. Open collector output
10| AIN3| Analog input, channel 3. Input range: 0-30V/0-10V DC
11| VCC (+)| Power supply (+10-30 V DC)
12| CAN 1H| SAE J1939 CAN interface High channel 1
13| 1WIRE DATA| Data channel for Dallas 1-Wire® devices
14| DIN3| Digital input, channel 3
15
| IGN (DIN1)| Digital input, channel 1. DEDICATED FOR IGNITION INPUT
16| CAN 2H| SAE J1939 CAN interface High channel 2
17| AIN1| Analog input, channel 1. Input range: 0-30V/0-10V DC
18
| DOUT4/AIN4| Digital output. Open collector output OR Analog input,
channel 4. Input range: 0-30V/0-10V DC
19| DOUT1| Digital output. Open collector output
20
| K-Line| K-LINE interface for online Tachograph Vehicle Data transfer
Wiring scheme
Set up your device
How to insert SIM card and connect the battery
- Unscrew 4 screws counterclockwise that are located on the bottom of the device.
- Remove the cover.
- Insert SIM card as shown with PIN request disabled or read Security info how to enter it later in Teltonika Configurator. Make sure that SIM card cut-off corner is pointing forward to slot. SIM slot 1 is closer to PCB, SIM slot 2 is the upper one.
- Connect battery as shown to device.
- After configuration, see “PC Connection (Windows)”, attach device cover back.
- Screw in all screws. Device is ready to be mounted.
PC Connection (Windows)
- Power-up FMB640 with DC voltage (10 – 30 V) power supply using power wires. LED’s should start blinking, see “LED indications”.
- Connect device to computer using Micro-USB cable or Bluetooth connection:
- Using Micro-USB cable
- You will need to install USB drivers, see “How to install USB drivers (Windows)”
- Using Bluetooth
- FMB640 Bluetooth is enabled by default. Turn on Bluetooth on your PC, then select Add Bluetooth or other device > Bluetooth. Choose your device named – “FMB640_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
- You are now ready to use the device on your computer.
How to install USB drivers (Windows)
- Please download COM port drivers from here.
- Extract and run TeltonikaCOMDriver.exe.
- Click Next in driver installation window.
- In the following window click Install button.
Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.
Configuration (Windows)
At first FMB640 device will have default factory settings set. These settings
should be changed according to the user’s needs. Main configuration can be
performed via Teltonika Configurator software. Get the latest Configurator
version from here. Configurator operates on Microsoft Windows OS and uses
prerequisite MS .NET Framework. Make sure you have the correct version
installed.
Table 1 MS .NET requirements
MS .NET REQUIREMENTS
Operating system| MS .NET Framework version|
Version
|
Links
---|---|---|---
Windows Vista Windows 7
Windows 8.1
Windows 10
|
MS .NET Framework 4.6.2
|
32 and 64 bit
|
Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking in the right bottom corner (Figure 10 Language selection).
Configuration process begins by pressing on connected device (Figure 11 Device connected via USB).
After connection to Configurator Status window will be displayed (Figure 12 Configurator Status window).
Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. FMB640 has one user editable profile, which can be loaded and saved to the device. After any modification of configuration, the changes need to be saved to device using Save to device button. Main buttons offer following functionality:
- Load from device – loads configuration from device.
- Save to device – saves configuration to device.
- Load from file – loads configuration from file.
- Save to file – saves configuration to file.
- Update firmware – updates firmware on device.
- Read records – reads records from the device.
- Reboot device – restarts device.
- Reset configuration – sets device configuration to default.
Most important configurator section is GPRS – where all your server and GPRS
settings can be configured and Data Acquisition – where data acquiring
parameters can be configured.
More details about FMB640 configuration using Configurator can be found in our
Wiki.
Quick SMS configuration
Default configuration has optimal parameters present to ensure best
performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:
” setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0;”
Note: Before SMS text, two space symbols should be inserted.
GPRS settings:
GPRS settings:
· 2001 – APN
· 2002 – APN username (if there are no APN username, empty
field should be left)
· 2003 – APN password (if there are no APN password, empty field
should be left)
Server settings :
· 2004 – Domain
· 2005 – Port
· 2006 – Data sending protocol (0 – TCP, 1 – UDP)
Default configuration settings
Movement and ignition detection:
- Vehicle movement will be detected by accelerometer
- Ignition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
- 300 seconds passes
- Vehicle turns 10 degrees
- Vehicle drives 100 meters
- Speed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
- 1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
- If device has made a record it is sent to the server every 120 seconds
After successful SMS configuration, FMB640 device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.
Mounting recommendations
- Connecting Wires
- Wires should be connected while module is not plugged in.
- Wires should be fastened to the other wires or non-moving parts. Try to avoid heat emitting and moving objects near the wires.
- The connections should not be seen very clearly. If factory isolation was removed while connecting wires, it should be applied again.
- If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied.
- Wires cannot be connected to the board computers or control units.
- Connecting power source
- Be sure that after the car computer falls asleep, power is still available on chosen wire. Depending on car, this may happen in 5 to 30 minutes period.
- When module is connected, be sure to measure voltage again if it did not decrease.
- It is recommended to connect to the main power cable in the fuse box.
- Use 3A, 125V external fuse.
- Connecting ignition wire
- Be sure to check if it is a real ignition wire – power does not disappear while starting the engine.
- Check if this is not an ACC wire (when key is in the first position, most electronics of the vehicle are available).
- Check if power is still available when you turn off any of vehicles devices.
- Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output, when ignition is on, may be chosen.
- Connecting ground wire
- Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
- If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
- For better contact scrub paint from the place where loop is connected.
PAY ATTENTION! Connecting the power supply must be carried out in a very low impedance point of on-board vehicle network. Connecting the GND at an arbitrary point to the mass of the car is unacceptable, as static and dynamic potentials on the line GND will be unpredictable, which can lead to unstable FMB640 operation and even its failure.
LED indications
Table 2 Navigation LED indications
BEHAVIOUR | MEANING |
---|---|
Permanently switched on | GNSS signal is not received |
Blinking every second | Normal mode, GNSS is working |
Off
| GNSS is turned off because:
Device is not working or Device is in sleep mode
Blinking fast constantly| Device firmware is being flashed
Table 3 Status LED indications
BEHAVIOUR | MEANING |
---|---|
Blinking every second | Normal mode |
Blinking every two seconds | Sleep mode |
Blinking fast for a short time | Modem activity |
Off
| Device is not working or Device is in boot mode
Characteristics
Basic characteristics
Table 4 Basic characteristics
MODULE
Name | Teltonika TM2500 |
---|---|
Technology | GSM, GPRS, GNSS |
GNSS
GNSS
| GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS
---|---
Receiver| 33/99 acquisition channel
Tracking sensitivity| -165 dBM
Accuracy| < 3 m
Hot start| < 1 s
Warm start| < 25 s
Cold start| < 35 s
CELLULAR
Technology | GSM/GPRS |
---|---|
2G bands | Quad-band 850 / 900 / 1800 / 1900 MHz |
GPRS | GPRS Mobile Station Class B |
Data transfer | GPRS Multi-Slot Class 12 (up to 240 kbps) |
Data support | SMS (text/data) |
POWER
Input voltage range | 10 – 30 V DC with overvoltage protection |
---|---|
Back-up battery | 550 mA 8,4V Ni-MH battery |
Internal fuse | 3 A, 125 V |
Power consumption
| At 12V < 7 mA (Deep Sleep)
At 12V < 12 mA (Online Deep Sleep) At 12V < 28 mA (GPS Sleep)
At 12V < 120 mA (GPRS)
At 12V < 65 mA (nominal with no load)
At 12V < 2.5 A Max. (with full Load / Peak)
INTERFACE
Digital Inputs | 4 |
---|---|
Digital Outputs | 4 |
Analog Inputs | 4 |
1-Wire temperature sensors | 6 |
1-Wire iButton | 1 |
RS232 | 2 |
RS485 | 1 |
CAN J1939 | 2 |
J1708 | 1 |
K-Line | 1 |
LVCAN/ALLCAN | 1 |
GNSS antenna | External High Gain |
GSM antenna | External High Gain |
USB | 2.0 Mini-USB |
LED indication | 2 status LED lights |
SIM | 2x SIM Card (Dual-SIM) |
Memory
| 2MB internal flash memory and Micro-SD card up to 32GB
FEATURES
Sensors | Accelerometer |
---|
Scenarios
| Green Driving, Over Speeding detection, Jamming detection, Excessive Idling detection, Towing detection, Crash detection, Immobilizer, iButton Read Notification
Functionalities
| Crash detection, Auto
Geofence, Manual Geofence, Trip Detection,
Odometer,
DDD download
and Tacho Online Data
Sleep modes| GPS Sleep, Online Deep Sleep,
Deep
Sleep
Configuration and firmware update| FOTA, FOTA Desktop, Teltonika Configurator
SMS| Configuration, Events, DOUT Control, Debug
GPRS commands| Configuration, Debug, DOUT Control
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring
| LLS (Analog), LV-CAN, ALL-CAN, CAN FMS,
RS232/RS485 Fuel Sensor, Ultrasonic level sensor
Ignition detection| Digital Input, Accelerometer, External Power Voltage
PHYSICAL SPECIFICATION
Dimensions | 104,1 x 76,8 x 31,5 mm (L x W x H) |
---|---|
Weight | 197 g |
OPERATING ENVIRONMENT
Operating temperature (without battery) | -40 °C to +85 °C |
---|---|
Storage temperature (without battery) | -40 °C to +85 °C |
Battery Charging temperature | Ta = 20 ± 5 ℃ (Ambient Temp.) |
Battery Discharge temperature | Ta = 20 ± 5 ℃ (Ambient Temp.) |
Battery storage temperature | -20 °C to +45° C |
Operating humidity | 5% to 95% non-condensing |
Ingress Protection Rating | IP41 |
Electrical characteristics
Table 5 Electrical characteristics
CHARACTERISTIC DESCRIPTION
| VALUE
---|---
MIN.| TYP.| MAX.| UNIT
SUPPLY VOLTAGE
Supply Voltage (Recommended Operating Conditions)|
+10
| |
+30
|
V
---|---|---|---|---
DIGITAL OUTPUT (OPEN DRAIN GRADE)
Drain current (Digital Output OFF) | 120 | µA | ||
---|---|---|---|---|
Drain current (Digital Output ON, Recommended Operating Conditions) |
0.5
|
A
Static Drain-Source resistance (Digital Output ON)| |
400
|
300
|
mΩ
DIGITAL INPUT
Input resistance (DIN1) | 15 | kΩ | ||
---|---|---|---|---|
Input resistance (DIN2) | 15 | kΩ | ||
Input resistance (DIN3) | 15 | kΩ | ||
Input resistance (DIN4) | 15 | kΩ | ||
Input voltage (Recommended Operating Conditions) |
0
| | Supply voltage|
V
Input Voltage threshold (DIN1, DIN2, DIN3, DIN4)| |
7.5
| |
V
ANALOG INPUT
Input Voltage (Recommended Operating Conditions), Range 1|
0
| |
+10
|
V
---|---|---|---|---
Input resistance| | 120| | kΩ
Input Voltage (Recommended Operating Conditions), Range 2|
0
| |
+30
|
V
Input resistance| | 147| | kΩ
1-WIRE
Supply voltage | +3.3 | +3.9 | V | |
---|---|---|---|---|
Output inner resistance | 7 | Ω | ||
Output current (UOUT> 3.0 V) | 30 | mA | ||
Short circuit current (UOUT> 0 V) | 75 | mA |
CAN INTERFACE
Internal terminal resistors CAN bus | 120 | Ω | ||
---|---|---|---|---|
Differential input resistance | 19 | 30 | 52 | kΩ |
Recessive output voltage | 2 | 2.5 | 3 | V |
Differential output voltage | 0.5 | 0.7 | 0.9 | V |
Common mode input voltage | -30 | 30 | V |
Safety information
This message contains information on how to operate FMB640 safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!
- The device uses SELV limited power source. The nominal voltage is +12 V DC. The allowed voltage range is +10…+30 V DC.
- To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
- When connecting the 2×10 connector cables to the vehicle, the appropriate jumpers of the power supply of the vehicle should be disconnected.
- Before dismounting the device from the vehicle, the 2×10 connector must be disconnected.
- The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard.
- The device FMB640 is not designed as a navigational device for boats.
- Do not disassemble the device. If the device is damaged, the power supply cables are not isolated or the isolation is damaged, DO NOT touch the device before unplugging the power supply.
- All wireless data transferring devices produce interference that may affect other devices which are placed nearby.
- The device must be connected only by qualified personnel.
- The device must be firmly fastened in a predefined location.
- The programming must be performed using a PC with autonomic power supply.
- Installation and/or handling during a lightning storm is prohibited.
- The device is susceptible to water and humidity.
Certification and Approvals
- FMB130 ANATEL
- FMB640 CE / RED
- FMB640 E-Mark
- FMB640 REACH
- FMB640 Declaration of IMEI assignment
- FMB640 Declaration of device operation temperature
- FMB640 RoHS
- FMB640 EAC
This sign on the package means that it is necessary to read the User‘s Manual
before your start using the device. Full User‘s Manual version can be found in
our Wiki.
This sign on the package means that all used electronic and electric equipment
should not be mixed with general household waste.
Hereby, Teltonika declare under our sole responsibility that the above
described product is in conformity with the relevant Community harmonization:
European Directive 2014/53/EU (RED).
Para maiores informações, consulte o site da ANATEL
www.anatel.gov.br
Este equipamento não tem direito à proteção contra interferência prejudicial e
não pode causar interferência em sistemas devidamente autorizados.
For more information, see the ANATEL website
www.anatel.gov.br
This equipment is not entitled to protection against harmful interference and
must not cause interference in duly authorized systems.
Warranty
TELTONIKA guarantees its products to be free of any manufacturing defects for
a period of 24 months. With additional agreement we can agree on a different
warranty period, for more detailed information please contact our sales
manager.
Contact us teltonika-iot-group.com/about-us/contacts/
All batteries carry a reduced 6 month warranty period.
If a product should fail within this specific warranty time, the product can
be:
- Repaired
- Replaced with a new product
- Replaced with an equivalent repaired product fulfilling the same functionality
- TELTONIKA can also repair products that are out of warranty at an agreed cost.
Warranty Disclaimer
TELTONIKA PRODUCTS ARE INTENDED TO BE USED BY PERSONS WITH TRAINING AND
EXPERIENCE. ANY OTHER USE RENDERS THE LIMITED WARRANTIES EXPRESSED HEREIN AND
ALL IMPLIED WARRANTIES NULL AND VOID AND SAME ARE HEREBY EXCLUDED. ALSO
EXCLUDED FROM THIS LIMITED WARRANTY ARE ANY AND ALL INCIDENTAL OR
CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO, LOSS OF USE OR REVENUE,
LOSS OF TIME, INCONVENIENCE OR ANY OTHER ECONOMIC LOSS.
More information can be found at teltonika-iot-group.com/warranty-
repair/
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>