heatit 4512671 ZM Single Relay 16A Thermostat User Guide

June 6, 2024
HEATIT

heatit 4512671 ZM Single Relay 16A Thermostat

INTRODUCTION

Heatit ZM Thermostat 16A is an electronic thermostat for electrical floor heating designed for inwall installations. The thermostat allows you to control your electrical heating through your Z-Wave network. The module is equipped with a 16A single pole relay. The thermostat requires you to connect an external sensor which is included with the device. The device can withstand a max load of 16A at 230VAC.

STATEMENT REGARDING PRODUCTS FROM MULTIPLE MANUFACTURERS

Please read this before installation

This device may be used with all devices certified with the Z-Wave PlusTM certificate and should be compatible with such devices produced by any manufacturer. Every primary controller is different depending on the manufacturer, their target audience and intended use/application. Please review the functionalities implemented by the primary controller you intend to use with our Z-Wave Plus certified device to ensure that it provides the necessary controls to take full advantage of our product’s capabilities.

INSTALLATION

Installation must be done by a qualified electrician in accordance with national building codes. Before installation, disconnect the power to the device. During installation of the device, power to the device must be disconnected AT ALL TIMES!

Wire the device as illustrated below. The product allows for wiring of cables with cross section of up to 1X2.5mm2

N Power connection (Neutral) 230VAC.
O Output. Load needs to be connected between
O and Neutral.
L Power connection (Live) 230VAC.
L Power connection (Live) 230VAC.
NTC 10K NTC Temperature sensor.
NTC 10K NTC Temperature sensor.

ADD/REMOVE

  1.  Set the primary controller to add mode (secure/non-secure).
  2. Press the configuration button 3 times in rapid succession.
  3. The device LED will flash green when the adding procedure has been successfully initiated.

When the device has been included in the home automation system, the LED will stay green for 3 seconds. The device is now ready for use with default settings.

If the adding process was unsuccessful, the LED will show a red light for 3 seconds. Please perform a “remove device” process and try to add again. If the LED goes red again, please see the full manual for more information regarding adding, removing and factory reset.

Adding/removing mode is indicated on the device by a flashing green lights. This lasts until timeout occurs after 90 seconds, or until the device has been added/removed from the network.

NB! When the device is removed from the gateway, the parameters are not reset. To reset the parameters, see the full manual.

LED PATTERNS

TECHNICAL DATA

Protocol Z-Wave
Chip Z-Wave 700 chip
Rated voltage 230VAC 50Hz
Max load 3600W 165A
Power Consum <1W
Ambient temp 5°C to 40°C (-30°C to 70°C storage)
Humidity Max 95% RH
Range RF Min. 40 meters
IP Code IP 20
Size (DxWxH) 46 x 45 x 25mm
Approvals Z-Wave Plus V2, CE, EN 60669-1:2018, EN 60669-2-1:2004 +

A1:2009, EN 60669-1:2004/A12:2010, EN 60669-2-5:2016, IEC 965-2-1, EN 62479:2010, ETSI EN 301 489-3 V2.1.1(2017-03), ETSI EN 300 220-2 V3.1.1(2017-02), RoHs 2002/95/EG, WEE 2002/96/EC

The device is maintenance-free. Indoor use only.

Heatit Controls AB can not be held liable for typographical errors, other errors or omittances in our information. Product specifications may change without further notice. All electrical installations must be carried out by a licensed electrician. The product must be installed in accordance with national building codes and our installers manual.

Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN Phone: +47 61 18 77 77 |post@heatit.com ­ www.heatit.com

Read the full manual at: Quick Guidemanuals.heatit.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals