HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

June 1, 2024
HEATIT

HEATIT 54 305 41 WiFi6 Thermostat

HEATIT-54-305-41-WiFi6-Thermostat-product

Product Information

Specifications

  • Product Name : Heatit WiFi6
  • Article Numbers: 54 305 41, 54 305 42, 54 305 43
  • Doc. Version: 2024-B
  • Colors Available: White RAL 9003, White RAL 9010, Black matt
  • Maximum Load: 16A/3600W at 230VAC
  • Recommended for loads above 13A

Product Usage Instructions

Installation Disclaimer

Installation must be done by a qualified electrician following national building codes. Disconnect power before installation.

Quick Start Guide

  1. Switch off the mains voltage and open the junction box.
  2. Connect wires as per the Connections section.
  3. Add external sensors if needed.
  4. Switch on the mains voltage and configure Wi-Fi via the MyHeatit App.
  5. The thermostat will display “INCL” when successfully added.

Connections

Max tightening torque for terminal screws: 2Nm. Use end sleeves for multiple- strand cables. Supports cables up to 1×2.5mm cross-section.

To access terminal screws, detach the front piece by gently pulling outwards from the sides.

Floor sensor: NTC type 6.8, 10, 12, 15, 22, 33, 47, or 100k (Default: 10k).

External sensor: NTC type 6.8, 10, 12, 15, 22, 33, 47, or 100k.

FAQ

  • Q: How do I control the Heatit WiFi6 thermostat?
    • A : The thermostat can be controlled via the MyHeatit App using  Wi-Fi or Bluetooth, or directly through the buttons on the front of the thermostat.
  • Q: What is the maximum load the Heatit WiFi6 can withstand?
    • A : The device can handle a maximum load of 16A/3600W at 230VAC. For loads above 13A, it is recommended to use a contactor.
  • Q: Can I integrate the Heatit WiFi6 with Amazon Alexa or Google Home?
    • A: The device supports Amazon Alexa and Google Home through its open API (pending approval).

Quick Guide

HEATIT-54-305-41-WiFi6-Thermostat-fig \(1\)

INTRODUCTION

Heatit WiFi6 is an electronic thermostat designed for electrical heating. The thermostat can be controlled using the ”MyHeatit” App via Wi-Fi, Bluetooth (BLE), or by the buttons on the front of the thermostat. The thermostat has a user-friendly interface.

Heatit WiFi6 has 3 modes; Heat – Cool and Eco.

The thermostat fits in standard European junction boxes and may be used with most System 55 frames. It has a sturdy metal frame for secure fastening on the junction box. The thermostat has a built-in room temperature sensor. Two additional external temperature sensors may also be connected. The device has an open API and supports Amazon Alexa and Google Home (open API, Amazon Alexa and Google Home is pending).
The thermostat can communicate over a local API, where the user can make integrate with a local gateway, server, or controller that o° ers such a service.
The installer can configure and set up the system via Bluetooth. After the system is set up, the installer can transfer the property to the customer. The customer can then add the system to their Wi-Fi network.
Heatit WiFi6 has active power metering and it gives you real-time information about your power consumption. It also allows you to set the power metering value manually in case of connection with a contactor.

The device has implemented ZeroX technology.

This technology makes sure the relay switches at 0V when turning on and off . With this technology, the thermostat will have a much longer lifetime.
The device can withstand a load of max. 16A/3600W at 230VAC. We recommend a contractor for loads above 13A.

INSTALLATION DISCLAIMER

Installation must be done by a qualifi ed electrician in accordance with national building codes. Before installation, disconnect the power to the device from the mains. During installation of the device, power to the device must be disconnected AT ALL TIMES!

QUICK START

Upon connecting the device to power, it will automatically enter add mode for a duration of 60 minutes.

  1. Switch o° the mains voltage (disable the fuse).
  2. Open the junction box.
  3. Connect the wires according to the description in chapter “Connections”. Optional: Connect external wired sensors.
  4. After verifying the connections, switch on the mains voltage.
  5. In the ”MyHeatit” App, choose ’Add Device’, enter your Wi-Fi details, search for and select your device.
  6. The thermostat will display “INCL” when the thermostat is successfully added.

Upon connecting the device to power, it will automatically enter add mode for a duration of 60 minutes.

NB! If adding/removing fails, Err (error)

CONNECTIONS

Max tightening torque for terminal screws: 2Nm.

If the cable used has multiple strands, using a end sleeve is advised. The product allows for wiring of cables with a cross-section of up to 1×2.5mm.
To access the terminal screws, hold the sides of the display and gently pull them outwards to detach the front piece.

HEATIT-54-305-41-WiFi6-Thermostat-fig \(2\)

  • Floor sensor : NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ
  • Default 10kΩ.
  • External sensor: NTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ.
  • Default 10kΩ.
  • N : Power connection (Neutral) 230VAC.
  • Heating N : Heating cable N connection.
  • L : Power connection (Live) 230VAC.
  • Heating L : Heating cable L connection.

INSTALLATION

Position the thermostat and mount it into the junction box using 2 screws. Position the thermostat front over the part mounted in the junction box, then carefully press the front until

it clicks into place. In order to get power metering values, the load needs to be connected to both heating L + N.
Never change the front from one thermostat to another

ADD/REMOVE

Upon connecting the device to power, it will automatically enter add mode for a duration of 60 minutes. During this time the device can be added to the app without starting add mode on the thermostat.

To remove a device, fi nd the device in the ”MyHeatit” App and choose “Delete this device”. If the app is unavailable, or if the thermostat is unreachable from the app, perform a ”Factory Reset”.

Method 1: Wi-Fi and Bluetooth

Add mode is indicated on the device by rotating LED segments in the display. It indicates this for 90 seconds until a timeout occurs, or until the device has been added to the network. Add mode may also be canceled by performing the same procedure as for starting add mode.

  1. Hold the center button for 5 seconds. The display will show ”OFF”.
  2. Press the ”+” button once to see “CON” in the display.
  3. Start the confi guration mode on the thermostat by holding the center button for approximately 2 seconds.
  4. In the ”MyHeatit” App, choose ’Add Device’. Choose Wi-Fi or Bluetooth, and search for your device, and select it.

The device is now ready for use with default settings.

NB! When the device is removed from the ”MyHeatit” App, the parameters are reset.

If inclusion fails, please perform a ”Factory Reset”.

Method 2: QR Code

  1. Hold the center button for 5 seconds. The display will show “OFF”.
  2. Press the ”+” button once to see “CON” in the display.
  3. Start the add mode on the thermostat by holding the center button for approximately 2 seconds.
  4. In the ”MyHeatit” App, “Add Wi-Fi device” or “Add Bluetooth device”.
  5. Press the QR Code button in the bottom right and scan the QR code on the device.

CHOICE OF SENSOR

The thermostat has multiple sensors and sensor modes. This lets you confi gure the thermostat to work correctly in most installations. The sensors and modes may be selected from either the local settings menu or via Parameter 2; ”Sensor mode (“OPER”)”.

Available sensor modes

  • F: Floor sensor
  • A : Internal room sensor
  • AF : Internal room sensor + Floor sensor
  • A2 External room sensor
  • A2F: External room sensor + Floor sensor
  • PWER: Power regulator mode (no sensor used)

NOTE: Some types of the floor require that a floor sensor is connected in order to limit the floor temperature to a maximum of 27°C (check the manual from the floor manufacturer). When the thermostat is used in (AF or A2F) the floor limiter FHI is automatically set to 27°C. When using any other sensor type (A, F or A2) the minimum and maximum limits are 5°C and 40°C respectively.

FACTORY RESET

Enter the menu by holding the center button for about 5 seconds, and navigate in the menu with the ”+” button till you see ”FACT”. Press the center button until you see “– –” blinking in the display, then hold for about 5 seconds to perform a reset. You may also initiate a reset by holding the right and center buttons for 60 seconds.
When either of these procedures has been performed, the thermostat will perform a complete factory reset. The device will display “RES” for 5 seconds while performing a factory reset.
When “RES” is no longer displayed, the thermostat has been reset.

ERROR CODES

  • Err Adding fail
  • See Manual : Chapter “Add/remove”.
  • Err1 Internal error
    • Most probably a faulty unit. Contact support.
  • Err2 Wi-Fi error
    • Most probably a faulty unit. Contact support.
  • Err3 Internal error
    • Most probably a faulty unit. Contact support.
  • Err4 Floor sensor error
    • You have chosen F, AF or A2F sensor mode without having a floor sensor connected, or the sensor may be damaged.
  • Err5 External sensor error
    • You have chosen A2 or A2F sensor mode without having an external sensor connected, or the sensor may be damaged.
  • Err6 Overheating
    • Contact your electrician.
  • Err7 Overload
    • Contact your electrician.

DISPLAY ICONS

HEATIT-54-305-41-WiFi6-Thermostat-fig \(3\)

TECHNICAL DATA

  • Protocol Wi-Fi: 2.4GHz/BLE
  • Rated voltage : 230VAC 50Hz
  • Max load :3600W 16A (resistive load)
  • Contactor recommended for loads above 13A
  • Max current : 16A
  • Power consumption: <2W
  • Power regulator Time cycle : 30 min.
  • Ambient temperature: 5°C to 40°C
  • Temperature range : 5°C to 40°C
  • Storage temperature: -30°C to 70°C
  • Hysteresis: 0.3°C to 3.0°C (default 0.5°C)
  • Humidity : 10% to 85% RH
  • Compatible with NTC sensor
  • with values: 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ @ 25°C
  • Screw terminals: Max. 2.5mm (2)2Nm
  • IP Code : IP21
  • Size (LxWxH): 84 x 84 x 45.5mm
  • Approvals: CE, Nemko
  • MAINTENANCE

The product is maintenance-free. Indoor use only

GET THE MYHEATIT APP HERE

HEATIT-54-305-41-WiFi6-Thermostat-fig \(4\)

We develop and design our products according in accordance with our strict quality requirements (ISO 9001) and environmental requirements (ISO 14001). All electrical installations must be carried out by an authorized electrical installer. The product must be installed in accordance with our installers’ manual and national building codes. Any wrongful installation, misuse, damage of the product, is not covered  under warranty. Updated documentation is available at www.heatit.com and/or documents.heatit.com. Heatit Controls AB can not be held liable for any type of errors or omittances in our product information. Product specifications may change without further notice.

Heatit Controls AB l Läkarvägen 4, 454 31 BRASTAD, SWEDEN

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals