heatit 4512673 ZM Thermostat 16A Instructions
- June 5, 2024
- HEATIT
Table of Contents
Heatit ZM Thermostat 16A
HEATIT ZM THERMOSTAT
– Relay 16A
Heatit ZM Thermostat 16A is an electronic thermostat for electrical floor
heating designed for inwall installations. The thermostat allows you to
control your electrical heating through your Z-Wave network. The module is
equipped with a 16A single pole relay. The thermostat requires you to connect
an external wired sensor which is included with the device. The device can
withstand a max load of 16A at 230VAC.
Heatit ZM Thermostat has a power metering feature that allows you to monitor
the power consumption of your connected devices.
Heatit ZM Thermostat has SmartStart. This feature allows the user to include
all devices with SmartStart by scanning the QR codes on the devices. On
startup, all the devices will automatically be included in the gateway
(requires SmartStart compatible primary controller).
PRODUCT INFO Heatit ZM Thermostat 16A
FEATURES
- Z-Wave thermostat for inwall installations
- 16A/3600W
- NTC 10 kΩ sensor
- SmartStart
- Firmware update (OTA)
- Power Metering
- Supports encryption modes S0, S2 Authenticated Class, S2 Unauthenticated Class
This is a Z-Wave Plus product with S2 security. The product must be used with an S2 enabled Z-Wave Controller in order to fully utilize the product.
TECHNICAL DATA
Protocol | Z-Wave, 868.4MHz |
---|---|
Chip | Z-Wave 700 chip |
Rated voltage | 230VAC 50Hz |
Max load | 3600W 16A |
Power Consumption | <1W |
Ambient temperature | 5°C to 40°C (-30°C to 70°C storage) |
Humidity | Max 95% RH |
Range RF | Min. 40 meters |
IP Code | IP 20 |
Size (DxWxH) | 46 x 45 x 25mm |
Approvals | Z-Wave Plus V2, CE |
EN 60669-1:2018, EN 60669-2-1:2004 + A1:2009, EN 60669-1:2004/A12:2010, EN 60669-2-5:2016, IEC 965-2-1, EN 62479:2010, ETSI EN 301 489-3 V2.1.1(2017-03), ETSI EN 300 220-2 V3.1.1 (2017-02), RoHS 2002/95/EG, WEE 2002/96/EC
MAINTENANCE
The device is maintenance-free. Indoor use only.
WARRANTY
10 yrs
ART. NO. | PRODUCT | COLOR | FREQUENCY |
---|---|---|---|
45 126 73 | Heatit ZM Thermostat 16A | Grey RAL 6015 | EU 868.4MHz |
WARRANTY – YOUR SAFETY
Product specifications may change without further notice. All electrical
installations must be carried out by a licensed electrician.
The product must be installed in accordance with national building codes and
our installers manual.
www.heatit.com
Thermo-Floor AS can not be held liable for typographical errors, other errors, or omittances in our information.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>