BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual

June 6, 2024
BANNER

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction
Manual

Models

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual -
Models

Wiring Diagrams

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Wiring
Diagrams

IO-Link Process Data Out (Master to Device)

IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-LINK protocol and specifications, please visit www.iolink.com.

For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com.

Segment Mode
Configure the light to have up to 10 segments which scale in size automatically with the length of the light or select Manual Segment Configuration which allows each segment to have a custom LED width and LED offset from the beginning of each segment to the beginning of the light. Use process data to set each segment to off, solid on, flash, or animation mode. Use parameter data to change segment number and configuration, color, intensity, flash speed, direction, background, threshold markers, and select animation type.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Segment
Mode

Run Mode
Use process data to control entire light and select color, intensity, flash, direction, and animations. Use parameter data to create custom colours, intensity, and flash speeds.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Run
Mode BANNER WLS15 Pro
LED Strip Light with IO-Link Instruction Manual - Run
Mode

Level Mode
Use process data to set the level value. Use parameter data to set range, thresholds, colours, intensities, flash speeds, background, threshold markers, and animation types.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Level
Mode

Dim and Blend Mode
Dim and blend mode uses the light to finely adjust the intensity of one color, or blend between two or three colors. Use process data to set the dim and blend mode value. Use parameter data to set number of colors, range, colors, and intensities.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Dim and
Blend Mode BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Dim and
Blend Mode

Gauge Mode
Gauge mode uses the light to display a colored band of LEDs in a position proportional to the gauge mode value. Use process data to set the gauge mode value. Use parameter data to set range, thresholds, colors, intensities, flash speeds, background, threshold markers, and animation types.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Gauge
Mode

LED Mode
Use process data to turn on and select a color for each individual LED. Use parameter data to set global intensity.

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - LED
Mode

Demo Mode
Demo sequence cycles through 12 different configurations to highlight example applications.

Specifications

Supply Voltage
18 V DC to 30 V DC Use only with suitable Class 2 power supply (UL) or a SELV power supply (CE)

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual - Supply
Voltage

Note: Different IO-Link masters have different maximum current limits. Use CSBM1251FM1251M splitter cable and external power supply if needed. See Accessories.

Supply Protection Circuitry Protected against reverse polarity and transient voltages

Note: Do not spray cable with high-pressure sprayer, or cable damage will result.

Construction
Clear anodized aluminum housing Polycarbonate outer housing Polyamide end caps

Connections
150 mm (6 in) PVC cable with a 4-pin M12 male quick disconnect Models with a quick disconnect require a mating corset

Input Response Time
45 Ms maximum

Mounting
Integral mounting slots for M4 (#8) screws, tighten to 0.56 NM (5 in·lbf) max torque Multiple bracket options available Secure cables within 150 mm (5.9 in) of the light

Note: It is recommended to use the provided mounting bushings when mounting using the endcaps. Center the mounting bushings in each slot to allow for expansion and contraction. Install using a M4 (#8) screw in each bushing torqued to a maximum of 0.45 N-m (4 in-lbf). For 920 mm and 1200 mm models in environments that vary more than 10 °C (18 °F), it is recommended to use one of the mounting bracket options instead of the end cap slots. If using the LMBWLS15 clip bracket and additional attachment is desired, only one end may be fastened using one of the spacers provided in the LMBWLS15 hardware packet to allow the opposite end to expand and contract. See mounting options in the instruction manual for bracket and tape options that allow expansion and contraction over temperature variations.

Environmental Rating
Rated IEC IP66 and IEC IP67 Suitable for wet locations per UL 2108

Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 15G 11 Ms duration, half sine wave per IEC 60068-2-27

Operating Temperature
­40 °C to +50 °C (­40 °F to +122 °F) Storage Temperature: ­40 °C to +70 °C (­40 °F to +158 °F)

Certifications

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual -
Certifications icon

Light Characteristics
RGBW LED PWM Frequency: 1kHz

Dimensions

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual -
Dimensions

Accessories

Cordsets

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual -
Accessories

Mounting Accessories

LMBWLS15

  • Stainless steel clip bracket
  • Includes 3 clip brackets and 2 plastic spacers
  • Clearance hole for M5 hardware

LMBWLS15-150S

  • Set of 2 stainless steel swivel bracket, allows for 150° of movement
  • Clearance hole for M5 button head screw

LMBWLS15MAG

  • Set of 2 brackets
  • Magnetic mounting bracket for attachment to steel and iron surfaces

LMBWLS15TD

  • Includes 4 100 mm (4 in) strips of 3MTM Dual Lock™ realisable fasteners
  • Recommended for mounting to metal and plastic surfaces
  • Strong, pressure-sensitive adhesive bonds on contact

LMBWLS15TF

BANNER WLS15 Pro LED Strip Light with IO-Link Instruction Manual -
LMBWLS15TF

  • Includes 2 100 mm (4 in) strips of double-sided foam urethane strips
  • Acrylic adhesive provides high bond strength to most surfaces
  • Bonds to low surface energy plastics such as polypropylene and powder coated paints

All measurements are listed in millimetres [inches], unless noted otherwise.

Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement.

IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer.

Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714

BANNER Logo

© Banner Engineering Corp. All rights reserved

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals