DELL FN 410S PowerEdge FN I/O Module User Guide
- June 12, 2024
- Dell
Table of Contents
- Document Revision History
- Pre–requisites
- Supported Hardware
- New Dell Networking OS Version 9.14(1.14) Features
- Important Points to Remember
- Restrictions and Known Issues with Other Devices
- Changes to Default Behavior and CLI Syntax
- Documentation Corrections
- Deferred Issues
- Deferred FN I/O Module 9.14(1.0) Software Issues
- Fixed Issues
- Fixed S/W Issues for the FN I/O Module in Dell Networking OS Version
- Known Issues
- Known S/W Issues for the FN I/O Module Switch in Dell Networking OS
- Upgrading the Dell Networking OS Image, Boot Flash and Boot Selector
- Upgrading the CPLD
- Upgrading the CPLD Image
- Support Resources
- Documentation Resources
- Finding Documentation
- Contacting Dell Technologies
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELL FN 410S PowerEdge FN I/O Module
This document contains information on open and resolved caveats and operational information specific to the Dell Networking OS on the Dell PowerEdge FN I/O Module.
Current Release Version: 9.14(1.14)
Release Date: 2022-11-18
Previous Release Version: 9.14(1.13)
Caveats are unexpected or incorrect behavior, and are listed in order of
Problem Report (PR) number within the appropriate sections.
For more information on hardware and software features, commands, and
capabilities, refer to the Dell Networking support website at:
https://www.dell.com/support
Document Revision History
Table 1. Revision History
Date | Description |
---|---|
2022–11 | Initial release. |
Pre–requisites
The Dell Chassis Management Controller (CMC) version 1.41 is required to use
an FN I/O module switch running Dell Networking OS version 9.9.0.0 or later.
You can use the CMC out-of-band management interface to access and manage an
FN IOM Switch using the Dell Networking OS command-line interface. For more
information, see the Dell Chassis Management Controller Firmware User’s Guide
on the Dell Support website at
http://support.dell.com/support/edocs/systems/pem/en/index.htm.
Supported Hardware
The following hardware is supported with this platform:
Hardware
FN 410S I/O Aggregator: 4x10G SFP+
FN 410T I/O Aggregator: 4x10G Base-T
FN 2210S I/O Aggregator: 4x10G Combo ports with Ethernet and Fibre Channel
| NOTE: The FN I/O Module does not support using the cable Cisco SFP- H10GB-ACU10M revision 37-1150-01
New Dell Networking OS Version 9.14(1.14) Features
The following features have been added to the Dell PowerEdge FN I/O Module with Dell Networking OS Version 9.14(1.14): None.
Important Points to Remember
When an FN I/O Module is installed in a Dell PowerEdge FX2 server chassis:
- Starting 9.4(0.0) release, only ESC key can be used to break into the BLI/X-loader of the FN I/O Module during boot/reload procedure. For this feature to be effective, upgrade the boot selector as explained in Upgrading the Dell Networking OS Image section.
- FCoE traffic drops/outage is observed when the DCBx parameters are changed when the Module is operational. Outage is more with Broadcom CNAs (40 seconds) compared to Intel CNAs (10 seconds). Configure all CNAs and the required DCBx parameters before on boarding and making the FN I/O Module operational.
- Avoid connecting both the switch management interfaces (in band and out of band interfaces) to the same subnet.
Restrictions and Known Issues with Other Devices
- While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command at the beginning of the startup configuration if the write memory command is used at the end of the configuration.
- If you want to downgrade from Dell Networking OS version 9.14(1.14) to an earlier version, you must power cycle the I/O modules using CMC.
- Connections between an FN I/O Module and the following devices are not supported:
- Cisco fabric extenders (FEXes): Storage deployments are not supported; LAN deployments are supported.
- When an FN I/O Module interoperates with a Brocade B8000 switch, when you reboot the FN I/O Module, B8000 switch generates more PFC frames, which may result in the failure to establish the iSCSI sessions.
- In connections with a server using a Q-LOGIC CNA for converged traffic, a FIP snooping session may flap when nonstandard LAN traffic is transmitted with SAN traffic.
- In connections with a server using a Q-LOGIC CNA, FCoE sessions are cleared when the keepalive parameter in fcoe-map is toggled (disabled and enabled).
- In connections with a server using an Intel X520 CNA, the server may fail to boot from the SAN network if a Brocade CNA is also installed in the server.
- If an Intel X520 CNA adapter is used for any DCB connection, follow these steps to establish sessions to send and receive traffic on an FN I/O Module:
| NOTE: The interface connected to the Intel X520 CNA adapter must be manually shut/no shut for the full functionality after making the following changes.
-
On each server-facing port, enter the following commands in interface configuration mode. The dcbx version cee command configures a port to use the CEE (Intel 1.01) version of DCBX. Configure server-facing ports with the shutdown and no shutdown commands, as needed. For example:
DellEMC# interface tenGigabitEthernet 0/1 DellEMC(conf-if-te-0/1)# protocol lldp DellEMC(conf-lldp)# dcbx version cee DellEMC(conf-lldp)# exit DellEMC(conf-if-te-0/1)# no shutdown DellEMC(conf-if-te-0/1)# exit DellEMC#
- Display information on FIP-snooped sessions and check the entries in ENode Interface fields to see if you have established the FCoE session on a server-facing port. show fip-snooping sessions
EXEC Privilege
-
To ensure interoperability, the recommended LLDP and LACP timeout values that should be configured in devices to which the FN I/O Module connects (such as ToR switch and servers) are:
○ LLDP timeout: 30 seconds
○ LACP long timeout -
When 68-byte frames are sent at line rate to a server, the server-facing LACP connection may flap. This behavior is due to the server’s inability to send LACP control packets when handling incoming line-rate traffic.
-
If a Brocade VDX6730 switch is used for any DCB connection, enter the following commands for each port connected from the FN I/O Module to the Brocade switch:
DellEMC# interface tenGigabitEthernet 1/8
DellEMC(conf-if-te-1/8)# protocol lldp DellEMC(conf-lldp)# dcbx version cee DellEMC(conf-lldp)# exit
| NOTE: The interfaces or port channel connected to the Brocade switch must be manually shut/no shut after making the above changes. The dcbx version cee command configures a port to use the CEE (Intel 1.01) version of DCBX.
- The following features are not available in the Dell Networking OS:
- PIM ECMP
- Static IGMP join (ip igmp static-group)
- IGMP querier timeout configuration (ip igmp querier-timeout)
- IGMP group join limit (ip igmp group join-limit)
- If you use the interface range command to select multiple interfaces that are added to the management VRF, the ipv6 address command does not display the auto config option. You can configure the auto config command on individual interfaces.
- If you use the interface range command to select multiple interfaces that are added to the management VRF, the ipv6 nd command displays the following options but they do not take effect if you use them:
- dns-server
- hop-limit
- managed-config-flag
- max-ra-interval
- mtu
- other-config-flag
- prefix
- ra-guard
- ra-lifetime
- reachable-time
- retrans-timer
- suppress-ra
- When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
- When Support Assist is configured on the device, the company or person information is partly lost after the device reboots.
- REST API does not support AAA authentication.
Changes to Default Behavior and CLI Syntax
Following default behavior and CLI syntax changes occurred during the Dell Networking OS release:
- To enhance security, the default RSA key size has been changed to 2048 bits from 1024 bits from 9.14.1.10 onwards.
Documentation Corrections
This section describes the errors identified in the current release of the Dell Networking OS. None.
Deferred Issues
Caveats that appear in this section were reported in Dell Networking OS version 9.14(1.0) as open, but have since been deferred. Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution.
Deferred issues are reported using the following definitions.
Category | Description |
---|---|
PR # | Problem Report number that identifies the issue. |
Severity | S1 — Crash: A software crash occurs in the kernel or a |
running process that requires a restart of AFM, the router, switch, or
process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature
or negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed
information about the issue.
Work around| Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
Work around describes a mechanism for circumventing, avoiding, or recovering
from the issue. It might not be a permanent solution.
Deferred FN I/O Module 9.14(1.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version 9.14(1.0) as open, but have since been deferred. Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution. The following issues have been deferred in the Dell Networking OS version
Fixed Issues
Fixed issues are reported using the following definitions.
Category | Description |
---|---|
PR# | Problem Report number that identifies the issue. |
Severity | S1 — Crash: A software crash occurs in the kernel or a |
running process that requires a restart of AFM, the router, switch, or
process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed
information about the issue.
Work around| Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
The work-around is unnecessary, as the version of code for which this release
note is documented has resolved the issue.
Fixed S/W Issues for the FN I/O Module in Dell Networking OS Version
9.14(1.14)
| NOTE: Dell Networking OS 9.14(1.14) includes fixes for issues addressed in previous 9.14 releases. Refer to the respective release notes documentation for the list of issues fixed in earlier 9.14 releases.
The following issues are fixed in Dell Networking OS version 9.14(1.14):
PR#170363
Severity| Sev 2
Synopsis| When a more specific prefix is received from a BGP peer over a
less specific aggregate route, the BGP does not advertise the less specific
route.
Release Notes| When a more specific prefix is received from a BGP peer
over a less specific aggregate route, the BGP does not advertise the less
specific route.
Work around| None
Known Issues
Known issues are reported using the following definitions.
Category | Description |
---|---|
PR# | Problem Report number that identifies the issue. |
Severity | S1 — Crash: A software crash occurs in the kernel or a |
running process that requires a restart of AFM, the router, switch, or
process.
S2 — Critical: An issue that renders the system or a major feature
unusable, which can have a pervasive impact on the system or network, and for
which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little
or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed
information about the issue.
Work around| Work around describes a mechanism for circumventing,
avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Fixed Issues” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the issue.
Known S/W Issues for the FN I/O Module Switch in Dell Networking OS
Version 9.14(1.14)
The following issues are open in Dell Networking OS version 9.14(1.14):
None
Upgrading the Dell Networking OS Image, Boot Flash and Boot Selector
Images
This section describes the procedure to upgrade Boot Flash and Boot Sector Images in Dell PowerEdge FN I/O Module.
The FN I/O Module is preloaded with default Dell Networking OS. Each system must be upgraded individually to a new Dell Networking OS release.
| NOTE: The upgrade can also be performed through the Chassis Management Controller (CMC) user interface. See the Dell Chassis Management Controller (CMC) User’s Guide on the Dell Support website at http://support.dell.com.
To upgrade the Dell Networking OS, Boot Flash and Boot Selector Images, use the following steps:
-
Dell Networking recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.
-
Upgrade the Dell Networking OS in flash partition A: or B:
upgrade system [flash: | ftp: | scp: | tftp: | usbflash:] [A:| B:] EXEC Privilege
DellEMC# upgrade system tftp://10.16.127.149/dell-FN-B B: 04:06:16 : Discarded 1 pkts. Expected block num : 51. Received block num: 50 04:06:19 : Discarded 1 pkts. Expected block num : 65. Received block num: 64 !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!. Erasing IOM Secondary Image, please wait ..................................................................................................Writing........................................................................................................................................................................................................Mar 24 14:24:16: %STKUNIT0-M:CP %SYSADM-5-CPU_THRESHOLD: Overall cpu usage of management-unit is above threshold. Cpu1minUsage (97%) ....Mar 24 14:24:16: %STKUNIT0-M:CP %SYSADM-5-TASK_CPU_THRESHOLD: 1min cpu utilization of management-unit has exceeded the threshold. Top three processes are sysd (92.76%), tTftpTask (27.24%), system (5.94%) .................................................................................................! 45815213 bytes successfully copied System image upgrade completed successfully. DellEMC#Mar 24 14:24:33: %STKUNIT0-M:CP %DOWNLOAD-6-UPGRADE: Upgrade completed successfully Mar 24 14:24:57: %STKUNIT0-M:CP %SYSADM-5-CPU_THRESHOLD_CLR: Overall cpu usage of management-unit drops below threshold. Cpu1minUsage (61%) DellEMC#
-
Upgrade the Dell Networking OS for the stacked units.
upgrade system stack-unit [0-5 | all] [A: | B:] EXEC Privilege
If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed. DellEMC# upgrade system stack-unit all A: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Image upgraded to all DellEMC#
-
Verify that the Dell Networking OS has been upgraded correctly in the upgraded flash partition
show boot system stack-unit [0-5 | all] EXEC PRIVILEGE
The Dell Networking OS versions present in A: and B: can be viewed for individual units by specifying the stack unit id [0-5] in the command or for all the stack units by specifying all in the command.
DellEMC# show boot system stack-unit 0
Current system image information in the system:
=====================================================
Type Boot Type A B
-----------------------------------------------------
Stack-unit 0 FLASH BOOT 9.14.1.14[boot] 9.14.1.13
-
Upgrade the FN I/O Module Boot Flash and Boot Selector image.
upgrade boot [all | bootflash-image | bootselector-image] stack-unit [0-5 | all] [booted | flash: | ftp: | scp: | tftp: | usb flash:] [A: | B:]\ EXEC Privilege
Dell Networking OS version 9.14(1.14) requires FN I/O Module Boot Flash image version 4.1.1.1 and Boot Selector image version 4.1.0.1. If any higher versions of Boot Flash or Boot Selector versions are present in the unit, do not upgrade the Boot Flash and Boot Selector images respectively. The Boot Flash and Boot Selector images can be upgraded at the same time by specifying all in the command. It can be upgraded separately by selecting bootflash-image or bootselector-image respectively. The Boot Flash and Boot Selector images can be upgraded for individual stack units by specifying the particular stack unit ID from the range [0-5] in the command. These can be upgraded to all the stack units together by selecting all option instead of the stack unit ID. The Boot Flash and Boot Selector images can be saved in two partitions A: and B: The user can select the partition and specify A: or B: in the command.
DellEMC#upgrade boot bootflash-image stack-unit 0 booted
Current Boot information in the system:
========================================================================
Card BootFlash Current Version New Version
------------------------------------------------------------------------
Unit1 Boot Flash 4.1.1.1 4.1.1.1
***********************************************************************
* Warning - Upgrading boot flash is inherently risky and should only *
* be attempted when necessary. A failure at this upgrade may cause *
* a board RMA. Proceed with caution ! *
***********************************************************************
Proceed upgrade Boot Flash image for stack-unit 1 [yes/no]:yes
Erasing IOM Secondary Bootflash Image, please wait .!.!.!.!.!.!.!.!........................
Bootflash image upgrade for stack-unit 0 completed successfully.
DellEMC#upgrade boot boot selector-image stack-unit 0 booted
Current Boot information in the system:
========================================================================
Card BootSelector Current Version New Version
------------------------------------------------------------------------
Unit1 Boot Selector 4.1.0.1 4.1.0.1
***********************************************************************
* Warning - Upgrading boot selectors is inherently risky and should *
* only be attempted when necessary. A failure at this upgrade may *
* cause a board RMA. Proceed with caution ! *
***********************************************************************
Proceed upgrade Boot Selector image for stack-unit 1 [yes/no]: yes
Erasing IOM Boot Selector Image, please wait .!.!..!.!..!.!.......
Bootselector image upgrade for stack-unit 0 completed successfully.
DellEMC#
-
Change the Primary Boot Parameter of the FN I/O Module to the upgraded partition A: or B:
boot system stack-unit [0-5 | all] primary [system A: | system B: | tftp://] CONFIGURATION
-
Save the configuration so that the configuration will be retained after a reload using write memory command. write [memory] EXEC Privilege
In case of a stack setup, the configuration will be saved in the Management as well as the Standby units. DellEMC#write memory! Synchronizing data to peer Stack-unit!!!!!!! DellEMC#
-
Reload the unit.
reloadEXEC Privilege
DellEMC# reload Proceed with reload [confirm yes/no]: yes Mar 24 21:32:27: %STKUNIT0-M:CP %CHMGR-5-RELOAD: User request to reload the chassis syncing disks... done
-
Verify the FN I/O Module has been upgraded to the Dell Networking OS version 9.14(1.14).
show version EXEC Privilege
DellEMC#show version Dell Real Time Operating System Software Dell Operating System Version: 2.0 Dell Application Software Version: 9.14(1.14) Copyright (c) 1999-2021 by Dell EMC Inc. All Rights Reserved. Build Time: Thu Mar 24 08:41:19 2022 Build Path: /build/build04/SW/SRC Dell Networking OS uptime is 2 day(s), 0 hour(s), 37 minute(s) System image file is "system://A" System Type: PE-FN-410S-IOM Control Processor: MIPS RMI XLP with 2 Gbytes (2147483648 bytes) of memory, core(s) 1. 128M bytes of boot flash memory. 1 12-port GE/TE (FN) 12 Ten GigabitEthernet/IEEE 802.3 interface(s)
- Verify the FN I/O Module has been upgraded to the latest Boot Flash and Boot Selector versions.
show system stack-unit [0-5]
EXEC Privilege
DellEMC#show system stack-unit 0
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : PE-FN-410T-IOM - 12-port GE/TE (FN)
Current Type : PE-FN-410T-IOM - 12-port GE/TE (FN)
Master priority : 14
Hardware Rev : X00
Num Ports : 12
Up Time : 6 day, 23 hr, 37 min
Dell Networking OS Version : 9.14(1.14)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : A: 4.1.1.1 B: 4.1.1.1 [booted]
Boot Selector : 4.1.0.1
Memory Size : 2147483648 bytes
Temperature : 42C
Voltage : ok
Switch Power : GOOD
Product Name : Dell PowerEdge FN 410T IOM
Mfg By : DELL
Mfg Date :
Serial Number : TW000000000000
Part Number : 000000X00
Piece Part ID : TW-000000-00000-000-0000
PPID Revision : X00
Service Tag : N/A
Expr Svc Code : N/A
Chassis Svce Tag : test123
Fabric Id : A2
Asset tag :
PSOC FW Rev : 0xd
ICT Test Date : 0-0-0
ICT Test Info : 0x0
Max Power Req : 19712
Fabric Type : 0x3
Fabric Maj Ver : 0x1
Fabric Min Ver : 0x2
SW Manageability : 0x4
HW Manageability : 0xd
Max Boot Time : 3 minutes
Link Tuning : unsupported
Auto Reboot : enabled
Burned In MAC : 00:1e:c9:ee:00:02
No Of MACs : 3
Upgrading the CPLD
An FN I/O Module system with Dell Networking OS version 9.14(1.14) requires CPLD image 9.
Verify that a CPLD upgrade is required
To identify the CPLD version, use the following command:
DellEMC# show revision
-- Stack unit 0 --
IOM SYSTEM CPLD : 9
To view CPLD version that is associated with the Dell Networking OS image, use the following command :
DellEMC# show os-version
RELEASE IMAGE INFORMATION :
---------------------------------------------------------------------
Platform Version Size ReleaseTime
F-Series:FN 9.14(1.14) 45304356 Mar 24 2022 12:45:01
TARGET IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
runtime 9.14(1.14) Control Processor passed
BOOT IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot flash 4.1.1.1 Control Processor passed
BOOTSEL IMAGE INFORMATION :
---------------------------------------------------------------------
Type Version Target checksum
boot selector 4.1.0.1 Control Processor passed
CPLD IMAGE INFORMATION :
---------------------------------------------------------------------
Card CPLD Name Version
Stack-unit 0 IOM SYSTEM CPLD 9
Upgrading the CPLD Image
| NOTE: The upgrade fpga-image stack-unit 0 booted command is hidden when using the ? feature in the CLI. However, it is a supported command and is accepted when entered as documented.
To upgrade the CPLD image on the FN I/O Module:
-
Upgrade the CPLD image.
upgrade fpga-image stack-unit [0-5] bootedEXEC Privilege
DellEMC#upgrade fpga-image stack-unit 0 booted Current information for the system:
Card Device Name Current Version New Version
Unit0 IOM SYSTEM CPLD 6 9
- Warning - Upgrading FPGA is inherently risky and should *
- only be attempted when necessary. A failure at this upgrade may *
- cause a board RMA. Proceed with caution ! *
Upgrade image for stack-unit 0 [yes/no]: yes FPGA upgrade in progress!!! Please do NOT power off the unit!!! !!!!!!!!!!!!!!!!Seo 24 12:45:02: %I/O-Aggregator:0 %DOWNLOAD-6-FPGA_UPGRADE: stack unit 0 fpga upgrade success. Upgrade result :
Unit 0 FPGA upgrade successful Unit 0. Please power cycle to take effect.
-
Power cycle the switch (IO module) using the CMC interface or remove and reinsert the switch (OIR) from the chassis so that the CPLD upgrade takes effect.
| NOTE: The power cycle stack-unit 0 command does not load the latest CPLD version.
3. Check whether the CPLD has been upgraded to the latest version. show revisionEXEC PRIVILEGE
DellEMC# show revision -- Stack unit 0 -- IOM SYSTEM CPLD : 9
Support Resources
The following support resources are available for the FN I/O Module system.
Documentation Resources
This document contains operational information specific to the FN I/O Module
system.
For information about using the FN I/O Module, see the following documents at
http://www.dell.com/support:
- Installing the FN I/O Module System
- Quick Start Guide
- Dell Networking Command Line Reference Guide for the FN I/O Module System
- Dell Networking Configuration Guide for the FN I/O Module System
For more information about hardware features and capabilities, see the Dell
Networking website at https://www.dellemc.com/networking.
For more information about the open network installation environment (ONIE) –
compatible third-party operating system, see http://onie.org.
For more information about using the Web GUI – Dell Blade I/O Manager, see the
Dell Blade I/O Manager Online Help.
Issues
Issues are unexpected or incorrect behavior and are listed in order of Problem
Report (PR) number within the appropriate
sections.
Finding Documentation
This document contains operational information specific to the FN I/O Module system.
- For information about using the FN I/O Module, see the documents at http://www.dell.com/support.
- For more information about hardware features and capabilities, see the Dell Networking website at https://www.dellemc.com/networking.
- For more information about the open network installation environment (ONIE) — compatible third-party operating system, see http://onie.org.
Contacting Dell Technologies
| NOTE: If you do not have an active internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell Technologies product catalog.
Dell Technologies provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell Technologies for sales, technical support, or customer service issues:
Go to www.dell.com/support.
Notes, cautions, and warnings
| NOTE: indicates important information that helps you make better use of
your product.
|CAUTION: A CAUTION indicates either potential damage to hardware or loss
of data and tells you how to avoid the problem.
|WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
© 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owner
References
- Computers, Monitors & Technology Solutions | Dell Australia
- Computers, Monitors & Technology Solutions | Dell USA
- Support | Dell US
- Support | Dell US
- Dell Networking Solutions | Dell USA
- Computers, Monitors & Technology Solutions | Dell USA
- Dell Networking Solutions | Dell USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>