After the ZigBee gateway is configured, enter the gateway to add sub-devices, and wait for the actuator to be powered on and the system self-check is completed. long press access to setting ,short press to choose icon,short press to enter network connected mode, then long press , flashing access network connected mode. Please refer to the gateway manual for Zigbee gateway configuration.
Product
Product Specifications
- Power: 2* AA alkaline batteries
- Display accuracy::0.5℃
- Probe sensor::NTC(10k)1%
- Maximum route:4.5mm
- Default range of temperature adjustment:5~35°C
- Working environment temperature::-10~60°C
- Insulating condition: 0-50℃
- Running program: Set per 1 week as a cycle
- *Size(mm):5389.5mm**
- Range of temperature display::1~70°C
- Maximum current:90mA
- *Thread size:M301.5**
Displays & Buttons
No.| Icon|
---|---|---
A| Auto Mode;
Low battery;
Children lock;
Open Window function
B| Holiday mode;
Boost mode;
WIFI connection status Auto mode period
Set temperature/advanced options
Valve status
C| Time setting interface: hours setting; minutes setting
| | Long press to access setting interfaceConfirm key
---|---|---
E| | Decrease key
Long press 3s to lock/unlock keys
F| | Increase Key
Long press 3s access Boost function setting, Press any key during operation to
exit this function and return to the original working mode
Installation and initial commissioning
- After power on, the screen will show all for 3 seconds.
Time setting: flashing,press display hour setting,press or to adjust
value,press again display minutes setting,press or to adjust value,press again
to set week,press or to adjust value,press to confirm setting and remember
time.
Note:after actuator self-testing,under normal working status,if need to
modify time,please and press 3s access to setting. And press to choose , short
press enter time setting. the same as above method.
Display “AD”, press Start system self-check, when display “1”, this is the first step of system self-check. When Display “2”, this is the second step, after finish self-check, If there is no fault prompt, it will enter the normal working state. If there is a fault prompt, please handle the fault first, otherwise it will not enter the normal working state.
Malfunction
Error Code
| Description
---|---
E1|
Motor fault
E2
| Sensor fault
|
Flashing show low battery
Special Function description
Holiday mode: press 3s access to setting interface, short press to choose holiday mode then short press enter temperature setting, short press setting days setting,press or to adjust value,under holiday mode, short press to exit holiday mode
Open Windows Function:
- The actuator turns off the window opening function by default, if you need to use it, you can turn it on in the advanced option A2 setting [reset when changing the battery]
- When the actuator detects that the indoor temperature drops quickly to the valve closed setting value (adjustment range: 5℃-25℃), the valve will be closed for 15 minutes (adjustment range: 5-60 minutes), and it will be closed after the window opening function is completed. Return to the original operating mode, but the valve will be fully opened
Programming mode setting
Press about 3s access to setting interface,short press switch to , short press access to programming, short press to choose which item you want, First set the auto mode to 5 means 5+2 days, 6 means 6+1 days, 7 means 7 days), after press to access to hours setting, Short press access to temperature setting. press or to adjust value.
Automatic mode parameter setting sequence: After finish Auto modem setting(ex:5+2), press access to first period hours setting, press or to adjust value. press to access to first periof minute setting, press or to adjust value, press access to working days first period temperature setting, press or to adjust value, press to set second time period,third time period…… from working day to holiday, After setting, do not operate the button for 10 seconds, the setting parameters will be automatically saved and the normal working interface will be returned.
period
| Default period|
Default temperature
---|---|---
1
| 6:00-8:00| 20℃
2| 8:00-11:30|
15℃
3
| 11:30—12:30| 15℃
4| 12:30—17:30|
15℃
5
| 17:30—22:00| 20℃
6| 22:00—6:00|
15℃
Advanced options
Press about 3-5s to access to setting interface, Short press until flashing, press to access to advanced options,press or to adjust value, after finish setting every time, short press to set next option, after finishing all ,don’t operate, after 10s it will automatically save and exit.
No | Item | Setting parameters | default |
---|---|---|---|
A1 | Measuring temperature correction | -9-+9°C | 1°C accuracy correction |
A2 | Window ventilation function:Window temperature and window function | ||
operating time |
- display means close window ventilation function close,press key display 5°C means this function open(temperature setting range: 5-25°C)
- operating time:5-60min(after open function, press change setting)
| default of power on is means close
A3| Automatic lock if no operation more than 10 minutes| 0:close 1:open| 0
A4| The minimum limit of the setting temperature| 1-15°C| 5°C
A5| The maximum limit of the setting temperature| 16-70°C| 35°C
A6| BOOST mode operating time| 100s-900s , Steps of 100 seconds| 300Seconds
A7| Check valve opening| 0-99
99 mean valve open 100%
5 mean valve open 5%|
A8| Heating start/stop Temperature hysteresis| 0.5-1.5| 1
A9| Display mode| 0:vertical display 1:horizontal display|
0
AA| Control type of valve| 0: PID 1:ON/OFF| 0
AB| Rese| Display 88, using or to change to 00, press to reset, The screen
will be fully displayed for 2 seconds.|
---|---|---|---