AMP Lighting AWL-5006-B-BZ Low Voltage Landscape Lighting User Guide

June 6, 2024
AMP Lighting

Lighting
INSTALLATION & MAINTENANCE GUIDE 
AMP ® Low Voltage Landscape Lighting
AMP ® HydraPro MR11 In-Grade Light
AWL-5006-B-BZ

Important Safety Instructions: Read Before Installation

This fixture is intended for installation in accordance with local codes and the National Electric Code (NEC). Failure to adhere to these codes and instructions may result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation maintenance, or mounting situations.

  1. Make sure that the power is turned OFF before installing or servicing this fixture.
  2. Warning: this fixture is not intended to be installed within 10 feet [3 meters] of a pool, spa, or fountain.
  3. This fixture is intended to be used only with a power supply (transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
  4. Underground Low Energy Cable must not be buried over 6” (15.2 cm) in order to connect to the main low voltage cable.
  5. Wiring connections must be made with UL-listed wire connectors that are suitable for the application.
  6. Position the wire connector so that it is located within 6 inches (15.2 cm) from a building structure, a luminaire, or a fitting.

 Important Safety Instructions

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
The lighted lamp is HOT!

WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.

  1. Turn off/unplug and allow to cool before replacing the lamp.
  2. The lamp gets HOT quickly! Contact only switch/plug when turning on.
  3. Do not touch the hot lens, guard, or enclosure.
  4. Keep the lamp away from materials that may burn.
  5. Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
  6. Do not operate the luminaire fitting with a missing or damaged shield.
    SAVE THESE INSTRUCTIONS

Package Contents

A. (1) Fixture Body

Parts Required (Sold Separately)

A. (1) MR11 Lamp

Product Dimensions

Remove Faceplate

Use a screwdriver to loosen the screws on the faceplate and remove the lens from the fixture body.

Install Lamp

Insert the lamp with the correct wattage and type marked on the fixture label and push firmly into place.
CAUTION : Do not exceed the maximum wattage marked on the fixture label.

Place the lens and the faceplate back onto the fixture body and secure the removed screws in a star pattern using a screwdriver. Tighten until snug.

Dig Hole

Prepare a hole in the ground. Make sure there are approximately 3” spaces surrounding the fixture for pea gravel or sand.

Wire Connection

Strip both leads from the luminaire pigtail. Using two-wire connectors (sold separately), connect the leads from the fixture body to the main supply cable leads.

Fill Hole

Install the fixture in the hole and fill the hole with pea gravel or sand.
Install/Replace Glare Guard

Remove Faceplate

Use a screwdriver to loosen the screws on the faceplate and remove the lens from the fixture body.

Replace Faceplate

Place the lens and faceplate onto the fixture body and secure with previously removed screws in a star pattern. Hand tightens until snug with a screwdriver.

Faceplate Replacement Options

Install/Replace Lamp

Repeat step 1 – step 3 to remove the faceplate and expose the lamp. Replace it with the correct wattage and type marked on the fixture label. Then, reinstall the faceplate.
IMPORTANT: Lamps must be protected from moisture and dust at all times. Always reinstall the faceplate when removed.

Help Hotline:
1-813-978-3900 • Mon-Fri 9 am-6 pm (EST) 
Specifications and product details are subject to change without notice.
© Copyright 2020, AMP ® Lighting, Lutz FL USA 33549 • All rights reserved.
customersupport@amplighting.com • 813.978.3900
www.amplighting.com
IS-AWL-5006-B-BZ-ver1.pdf

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AMP Lighting User Manuals

Related Manuals