ARROW CDC-16123-XPCN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions Instructions

June 13, 2024
Arrow

ARROW CDC-16123-XPCN1A Pressure Injectable Three-Lumen Hemodialysis
Catheterization for High Volume - symbol 5

Pressure Injectable  Three-Lumen  Hemodialysis  Catheterization  for  High Volume Infusions

Contents:

1:00| Three-Lumen Catheter: 12 Fr. (4.06   mm   OD)   x   20 cm Pressure Injectable Radiopaque  Polyurethane
with Blue Flex Tip®, Extension Line Clamps
---|---
1:00| Spring-Wire Guide, Marked: .035″  (0.89 mm) dia. x 23-5/8″ 60 cm) (Straight Soft Tip  on One End -“J” Tip  on
Other)  with  Arrow®  Glide Wheel™  Wire Advancer
1:00| Catheter:  18  Ga.  x  2-1/2″  (6.35  cm)  Radiopaque  over  20  Ga.  RW Introducer Needle
1:00| Injection  Needle:  Safety Glide™ 1  25  Ga.  x  1″  (2.54  cm)
1:00| Blunt  Fill  Needle:  18  Ga.  x   1-1/2″  (3.81  cm)
1:00| Pressure  Transduction  Probe
1:00| Introducer Needle:
Echogenic  18  Ga.  x  2-1/2″  (6.35  cm)  XTW  and  5  mL  Arrow® Raul erson Spring-Wire  Introduction  Syringe
1:00| Injection Needle:
Safety Glide™ 1    22   Ga.   x   1-1/2″   (3.81   cm)  and  5  mL  Luer-Slip Syringe
1:00| Syringe:  3  mL  Luer-Lock
1:00| Tissue  Dilator:  10  Fr.  (3.5   mm)  x 10.2  cm
1:00| Tissue  Dilator:  12  Fr.  (4.0  mm)  x  14  cm
3:00| 10  mL  Luer-Lock  Pre-Filled  Saline  Syringe
1:00| 5  mL  1%  Lidocaine  HCl  Solution  and  Alcohol  Prep
2:00| 3  mL  Applicator  2%  CHG  and  70%   IPA  Chlora Prep® 2  One-Step Solution  with Hi-Lite   Orange™ Tint
1:00| Sharps Away®  II  Locking  Disposal  Cup
1:00| Sharps Away® Disposal  Cup
1:00| Maximal  Barrier  Drape™  with  4″  fenestration
1:00| Towel
1:00| Needle Holder
1:00| Safety Scalpel:  #11
1:00| Checklist/CLIP Sheet
1:00| Sterile Procedure  Sign
1:00| Medication Label: 1% Lidocaine
2:00| Gauze  Pad:  2″  x 2″ (5 cm x 5 cm)
5:00| Gauze  Pad:  4″  x  4″  (10  cm  x  10  cm)
1:00| Surgical  Apparel: Impervious  Gown
1:00| Dressing:  Tegaderm® 3  CHG  3-1/2″  x  4-1/2″  (8.5   cm x  11.5  cm)
1:00| Transducer  Cover:  14   cm  x 147  cm
1:00| Surgical  Apparel:  Mask  with  Eye  Shield
1:00| Surgical  Apparel:  Bouffant  Cap
1:00| Suture:  3-0  Silk  with  Curved  Needle
1:00| Tubing±:  20″  (50  cm)  Extension
1:00| Hemo Hopper®  Fluid  Receptacle

1A trademark of Becton, Dickinson and Company.
2 A registered trademark of CareFusion or one of its subsidiaries.
3A registered trademark of  3M Company.

±Precaution: Contains Phthalate: DEHP. Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex.
Store between 20 — 25°C (68 — 77°F).
Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication. Contraindications: The Multi-Lumen Acute Hemodialysis Catheter (AHDC) is not designed for long-term 30 days) hemodialysis or for insertion into thrombosed vessels.

LBL068961 R00 (2023-04)

Documents / Resources

| ARROW CDC-16123-XPCN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions [pdf] Instructions
CDC-16123-XPCN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions, CDC-16123-XPCN1A, Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals