Important: Please Read Before Installation

  1. This LED floodlight uses the latest in solid state lighting technology for long life, low maintenance, and high efficeiency.
  2. An internal power-factor-corrected switch mode supply allows this fix-ture to be used from any nominal 90V-277VAC, 60Hz supply without any variation in light output.
  3. Suitable for use in:
    A. Ambient Temperatures of: -20~+45°C (-4~+113°F)
    A. Wet Locations

Note : Save these instructions for future reference.

Important Safety Instructions

To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accor-dance with all applicable electrical codes.
To avoid electric shock:

  1. Be certain electrical power is OFF before and during installation and maintenance.
  2.  Luminaire must be connected to a wiring system with an equip-ment-grounding conductor.

To avoid explosion:

  1.  Make sure the supply voltage is the same as the rated luminaire voltage.
  2. Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous atmosphere.
  3.  Do not operate in ambient temperatures above those indicated on the luminaire.

For supply connections use wire rated for at least 90°C (194°F)
Warning: These luminaires should ONLY be installed by a qualified electrician.

Package Contents
A. (1) Fixture body

Parts Required
A. (1) Mounting Accessory (Sold Separately)

Products Model #

Model Input Voltage Hertz Input Cur- rent Watt

9W Flood Light

|

90-277

|

60

|

0.2

|

9

17W Flood Light

|

90-277

|

60

|

0.4

|

17

Product Dimensions

120VAC 17W
Two installation methods are provided for this fixture: Surface Mount- Page 5
Stake Mount- Page 6

Install Surface Mount to Fixture body

Glare Guard Pass the supply cable through the center hole of the surface mount. Then thread the surface mount onto the fixture body. Make sure the wire exit on the surface mount and the glare guard are facing the opposite direction after installation.

Option 1: Surface Mount

Install Fixture Body to Surface

Place the supply cable in the wire exit. Then attach the surface mount with the fixture body to the mounting surface and secure with self-tap-ping screws using a screwdriver to tighten.
NOTE: Wall anchors are required for brick walls or concrete walls. To determine anchor locations, place the surface mount onto your de-sired location and mark points using the hole on the surface mount as a guide.
Go to Step 3 – Step 4 for wiring connections and direction adjustments.

Option 2: Stake Mount

1 Install Stake

Determine the desired location for mounting the stake. Hammer the stake into the ground until flange of stake is flush to grade. To avoid damage to the stake, place a board on top of the stake while hammering.
Note: If the ground is hard and the stake is difficult to install, make a crosscut in the ground using a flat shovel.

2 Install Fixture Body to Stake

Pass the supply wires through the center hole of the stake and thread the fixture body onto the stake. Hand tight-en until snug. Clear away an area in the ground and lay the supply wires into the stake’s wire exit.
Go to Step 3 – Step 4 for wiring connections and direction adjustment.

Wire Connection

By using the Allen wrench, loosen screws and remove the cover from the hub body.
Insert the main supply cable, fixture supply cable, other fixture supply cable or next hub supply cable into the hub body from the different conduit. Strip both ends of all cables. Lift the clamps up and insert the ends of neutral wires into the “NEUTRAL” block. Insert the ends of live wires into the “HOT” block. Insert the ends of ground wires into the “GROUND” block. ensure that each wire is pushed into place securely and close the clamps.
Place the cover back onto the hub body and secure with previously removed screws. Hand tighten until snug with Allen wrench.

Adjust Fixture Body Direction

Using the Allen wrench, loosen the screw on the knuckle and adjust the fixture body to your desired direction. Once your desired direction is achieved, tighten the knuckle down with the Allen wrench.

Help Hotline:
Specifications and product details subject to change without notice.
© Copyright 2021, AMP® Lighting, Lutz FL USA 33549 • All rights reserved. customersupport@amplighting.com • 813.978.3900

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AMP Lighting User Manuals

Related Manuals