SPECIFICATION PARAMETER (GB)
Model number| COW494 / 4202515 UP-PL1221-7W- DD-P3| COW495
/ 4202520 UP-PL1521-9W- DD-P3| COW496/4202522 UP-
PL1721-12W- DD-P3| COW497/4202524 UP-PL2221-18W- DD-P3
---|---|---|---|---
Dimension(mm)| Ø120x21mm| Ø145x21mm| Ø170x21mm| Ø224x21mm
Power Consumption| 7W| 9W| 12W| 18W
Supply Voltage| 200-240V~| 200-240V~| 200-240V~| 200-240V~
Frequency| 50/60Hz| 50/60Hz| 50/60Hz| 50/60Hz
Color temperature| 3000K/4000K/5700K| 3000K/4000K/5700K|
3000K/4000K/5700K| 3000K/4000K/5700K
IP Rating| IP44/ IP20| IP44/ IP20| IP44/ IP20| IP44/ IP20
Lumen output| 3000 K| 4000 K| 5700 K
---|---|---|---
COW494| 7 W| 490 lm| 530 lm| 510 lm
COW495| 9 W| 690 lm| 750 lm| 700 lm
COW496| 12 W| 915 lm| 990 lm| 930 lm
COW497| 18 W| 1490 lm| 1620 lm| 1510 lm
Important safety instruction
To ensure correct function and safety, please read and follow all instructions carefully before using the product, Basic safety precautions should always be followed when installing, including the following:
- Turn offer power supply before installation or before doing any maintenance, cleaning, changing the globe or adjustment to the fitting.
- Do not install any luminaire near the heat source.
- IP grade please refer to the product label, only IP54 can be used in wet or damp locations,
- Do not exceed the nominal supply voltage or amperage ratings.
- All wiring and installation of the light fitting must adhere to local and national wiring rules.
- Take care not to pull any electrical wires during unpacking as this may damage the connection.
- Lay out all the components on a smooth surface and make sure three are no components missing before assembling.
- To avoid injury or damage to the fitting, please ensure that power leads and screws are secure before connecting the power.
- Please keep instructions for future reference.
Fig 1: Installation spacing
Tab 1: Ceiling cutout reference table
Panel light dia (mm) | Ø120 | Ø145 | Ø170 | Ø200 | Ø224 | Ø238 | Ø300 |
---|---|---|---|---|---|---|---|
Ceiling Cutout (mm) | Ø108-113 | Ø127-133 | Ø157-162 | Ø177-182 | |||
Ø205-212 | Ø224-228 | Ø282-288 |
NOTE: Before installation, please check the information of driver as below:
Non-dim | Cannot be used with any dimmer |
---|---|
Triac dim | Compliable with recommended TRIAC dimmers, dimming range 8-100% |
0/1-10V | Only work with 0/1-10V dimming system, dimming range 8-100% |
DALI | Only work with DALI dimming system, dimming range 8-100% |
Installation Procedure
Warning:
- Switch off before installation.
- Switch on only after complete installation and examination of the circuit
- Professional electrician for installation and maintenance only.
For a color changeable model (controlled by Slide Switch in a lamp), please
select a light color before installation, see the below picture.
Choose color by slide switch with corresponding color temperature.
LED Panel with external driver
|
---|---
1. Open a hole according to the cutout size of the LED Panel.| 2. Open the
quick junction box Connect the wire to the Junction box
|
3. Connect the LED Panel with the driver, hold back the spring clip then push
the LED Panel into the hole| 4. Make sure the LED Panel is fixed tightly in
the ceiling, and turn on the power (Fig 1).
This symbol on products and or accompanying documents indicates that used and end-of-life electrical and electronic equipment should not be disposed of in the household waste. For the proper disposal, treatment, recovery, and recycling, please take these products to designated collection points, where they will be accepted on a free of charge basis. Alternatively, in some countries, you may be able to return your products to your retailer upon the purchase of an equivalent new product. Disposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropriate waste disposal and handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation.
This symbol explains that the lamp is not suitable for covering with thermal insulating material.
Non-replaceable light source
Replaceable control gear by a professional
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>