Product Specification

Product dimensions| 245mm x 245mm x 50mm

(exclude universal mounting kit)

---|---
Product weights| 1.75kg
Radio frequency| One Wi-Fi 2.4GHz One Wi-Fi 5GHz

One Wi-Fi 2.4/5GHz(scanning)

One Bluetooth 2.4GHz

Operation frequency 2.4GHz

5GHz

Bluetooth low energy(V4.1)

| 2.4G : 2412 ~ 2462MHz

5G Band 1 : 5180 ~ 5240MHz

5G Band 4 : 5745 ~ 5825MHz BT : 2402 ~ 2480MHz

Networking interface| Two 5G mGig Ethernet ports
Antenna Gain| Wi-Fi 2.4GHz band : 4.6 dBi (Omni) Wi-Fi 5GHz band: 5 dBi (Omni)

Dual band Wi-Fi(2.4/5GHz): 4.6/5dBi (Omni)

BLE: 4.4dBi (Omni)

Max power consumption| 35watts
Max Tx Power| FCC:

Wi-Fi 2.4GHz band: 627.338mW Wi-Fi 5GHz band:

5180-5240 MHz: 477.372 mW

5745-5825 MHz: 585.520 mW

BLE: 6.637 mW IC:

Wi-Fi 2.4GHz band: 627.338mW Wi-Fi 5GHz band:

5180-5240 MHz: 57.687 mW

5745-5825 MHz: 585.520 mW

BLE: 6.637 mW

Power source| DC power:    12V/3.5A power adapter

Power over Ethernet(PoE): 802.3bt

---|---
Mounting mode| Ceiling,
Operation temperature| 0 ~ 45 C
Operation humidity| 5 – 95% Noncondensing
Altitude| 10,000ft (3,048m)

Installation of ceiling plate + AP on T-bar (9/16” & 15/16”)

STEP 1

STEP 2

Uninstallation of ceiling plate + AP from T-bar (9/16” & 15/16”)

STEP 1 STEP 2

Installation of RJ45 cable on the ceiling plate

STEP 1 STEP 2

Installation of ceiling plate + AP on wall mount

STEP 1 STEP 2

Regulatory Compliance Information:

Safety Notice

  • Please use CSA/UL Certification Approval & LPS’s External Power Adaptor. . Please connect with CSA/UL Certification Approval & LPS’s DC Source.
  • NWA1000 is indoor use Wireless AP.
  • There is a risk of fire if the battery is replaced with an incorrect type.

FCC Requirement for Operation in the United States of

America:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1.  this device may not cause harmful interference,
  2.  this device must accept any interference received, including interference that may cause undesired operation.

Guideline for Human Exposure

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 31
cm between the radiator & your body.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution

  • Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
  • For operation within 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range, it is restricted to the indoor environment.

Industry Canada statement

This device complies with ISED’s license-exempt RSS. Operation is subject to the
following two conditions:

  1. This device may not cause harmful interference,
  2. this device must accept any interference received, including interference that may cause undesired operation.

Caution :

  1. the device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems;
  2. where applicable, antenna type(s), antenna models(s), and worst-case tilt angle(s) necessary to remain compliant with the e.i.r.p. elevation mask requirement set forth in section 6.2.2.3 shall be clearly indicated

Radiation Exposure Statement:

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 38cm between the radiator & your body.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals