EcoDim ECO-DIM.11 Multicontrol LED-Dimmer Instruction Manual

June 6, 2024
EcoDim

EcoDim ECO-DIM.11 Multicontrol LED-Dimmer Instruction Manual

EcoDim Logo

ECO-DIM.11

Please note:

  • This is a two-wire dimmer that needs to be connected as shown under the header Connection diagram.
  • Installing the dimmer on a mains power supply of 230V needs to be done by a qualified professional and should take into account any national regulations. Ensure that the electricity is switched off during installation.

Input Voltage: 230V
Frequency: 50Hz
Maximum wattage: 250W
Minimum wattage: 0W
Dimming technology: Phase cut (trailing edge, R, C)
Dimmable led lamps: 0-250W
Bulbs with electronic transformers: 0-250W
Halogen and incandescent bulbs: 0-250W

Suitable brands of cover material

  • Berker by Hager
  • Busch-Jaeger
  • GIRA
  • JUNG
  • Merten by Schneider
  • NIKO
  • PEHA
  • KOPP

Features

  • Suitable for new installations and retrofit bulbs.
  • Multi-dim technology achieve multi-way dimming/switching with no extra wires
  • Soft start system for longer lifespan of LED bulbs.
  • Built-in protection against, overload and overheat protection.
  • Suitable for one-way and multi-way dimming.
  • Multiple dimmers can control the same set of lights, but each dimmer works independently and does not interfere with each other.
  • Self adaption at the maximum brightness to ensure no flickering appears

Connection

Connection

Step 1: Always make sure that the electricity is turned off during installation. Then connect the power wires as indicated in the ” Connection diagram.”

Step 2: Now install the dimmer in the flush-mounting box.

Step 3: Switch the electricity back on. Switch on the connected lamps using the dimmer shaft. Now set the MIN, as indicated under “MIN set up”.

Step 4: Replace the cover frame and the dimmer knob on the dimmer.

Connection diagram

Connection diagram

MIN. set light level

The minimum brightness is selected by a dip switch, which is convenient for the user to accurately control the brightness level of the lamp.

  1. Factory set min. brightness to 1
  2. All dimmers install in parallel must be set to the same dimming lever (switch position)

MIN set light level

Reduction of connected load by ­PowerFactor

When calculating the LED connected load of the dimmer, take the PowerFactor of the dimmable LED lighting into account. See the global calculation below for this.

Nominal power = number of LED light sources * Nominal power
LED / -PowerFactor.

Example: 10 lamps * (5W per lamp / 0.8 PowerFactor) = 62.5 Watt