EcoDim PRO-05 LED Dimmer Instruction Manual
- June 1, 2024
- EcoDim
Table of Contents
EcoDim BV.
Dr. Huber Noodtstraat 89
7001 DV, Doetinchem, Netherlands
(Imported by NJ Trading BV)
Manual ECODIM.05 PRO
Led dimmer
trailing edge
leading edge
PRO-05 LED Dimmer
Please note:
– This s duo dimmer and t shovid be connected as shown under the ‘heading
‘Wiring diagram:
Installation of the dimmer to a 230V mains power supply should be carred outby
a qualfed professional taking nto account national regulations.
During all work, make sure that the elctrcity is swiched off.
You cannot connect more than one dimmer i parallel. To then operate the same
load rom two points
Dimmer is notsuitable for wound/magnetic or core transformers.
WIRING DIAGRAM
MULTIWAY SWITCHING: OPTION 1 **MULTIWAY SWITCHING: OPTION 2![EcoDim PRO-05 LED Dimmer
- wiring diagram 3](https://manuals.plus/wp-content/uploads/2024/04/EcoDim- PRO-05-LED-Dimmer-wiring-diagram-3.png)**
SETTING MIN. LIGHT LEVEL
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible to the left (minimum light output). Do the lights blink? Then use a screwdriver to slowly turn the MIN potentiometer to the right for stable light. Is the light already stable? Then slowly turn the MIN to the left for even better dimmability, until just before the point the lamps start blinking. That is the best dimmability of these LED lamps. You can set this for both light groups.
SETTING MAX. LIGHT LEVEL
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible to the right (maximum light output). Do the lights blink? Then turn the MAX potentiometer slowly to the left for stable light. Is the light already stable? Then slowly turn the MAX to the right for even better dimmability, to just before the point when the lamps start flashing. This is the best dimmability of the LED lamps. You can set this for both light groups.
SPECIFICATIONS
Connection voltage: | 220-240VAC |
---|---|
Frequency: | 50/60Hz |
Dimming technology: | Trailing edge and leading edge (R,L,C) |
Dimmable LED lamps: | 2 x 0-200W Trailing (R,C) |
2 x 0-200W Leading (R,L)
Lamps with electronic transformers:| 5-250W
Halogen and incandescent lamps:| 5-250W
- Suitable for both retrofit bulbs and new installations.
- Two-wire connection – no neutral wire needed.
- Soft start system for longer LED lamp life.
- Overheat & overload protection.
SUITABLE BRANDS OF COVER MATERIAL (AVAILABLE SEPARATELY FROM ECODIM)
REDUCTION OF CONNECTION CAPACITY BY POWERFACTOR
When calculating the LED connection power of the dimmer, take into account the PowerFactor of the dimmable LED lighting. See the global calculation below for this.
Example: 10 lamps * (5W per lamp / 0.8 PowerFactor) = 62.5 Watt
INSTALLATION
Step 1
Connect the duo dimmer as shown in point 1: wiring diagram. For an
installation without two-way switching see the wiring diagram, for a situation
with two-way switching see multiway switching 2A or 2B.
Insert the installation wires into the appropriate connection ports of the
dimmer and screw them down firmly. After installing the installation wires,
check that they clamp properly in the connection ports of the dimmer.
Step 2
Now mount the dimmer in a single flush-mounting box and screw down.
Step 3
Now adjust the minimum and maximum light levels of the lamps on the dimmer.
This is indicated at point 3: Setting min. light level and 4: Setting max.
light level. After adjusting the lights, check whether the lamps remain stable
in both low and high light levels.
Step 4
Now place the cover frame and central plate on the dimmer. Next, place the
round plate on both dimmer channels first and then screw on the nut. Check
that the cover frame and central plate are firmly in place on the dimmer. See
point 6: Suitable cover frame brands for matching cover material.
https://www.ecodim.nl/en/eco-dim05-pro.html