IMPORTANT SAFETY MEASURES AND INSTRUCTIONS

WARNING!

  • Please read this manual before operating the appliance and keep it at a safe place for future reference. In case the appliance is obtained by a new owner, it should be transferred together with its manual.

  • CAUTION: Children under 3 years of age should be kept away from the appliance unless they are under constant supervision.
    Children from 3 to 8 years of age are allowed to operate the on/off button ONLY, provided that the appliance is installed and ready for operation and such children have been supervised and instructed in safe operation of the appliance and they understand all related risks.
    Children from 3 to 8 years of age MUST NOT: connect the plug to power sockets, make adjustments, clean it or carry out user maintenance operations.
    This appliance can be used by children older than 8 years of age and by people with reduced physical, sensor and mental capabilities, as well as by people with insufficient experience and knowledge provided they are supervised or instructed in safe operation of the appliance and understand the related risks. Children should not be allowed to play with the appliance. Cleaning and user maintenance operations must not be carried out by children without supervision.

  • CAUTION: Some of the appliance parts may get very hot during operation and thus cause burns to users. In case there are children and vulnerable people in the room, special attention should be paid.

  • WARNING: Do not cover the appliance in order to prevent overheating!

  • The appliance must not be placed right under a socket box!

  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

  • Before connecting the appliance to the mains, check if the voltage indicated on its technical plate corresponds to the voltage of the electricity, supplied to your house.

  • This appliance shall be used only for the purpose it has been designed and intended for, i.e. heating of domestic premises. The appliance is not intended for commercial/industrial application. Every other use is to be considered improper, and therefore dangerous. The manufacturer doesn’t bear responsibility for damages arising from improper and irrational use. Non-adherence to these instructions would render the warranty invalid!

  • Do not leave your home while the heater is operating: make sure that the power switch is in OFF position (panel heaters with mechanical control).

  • Keep inflammable objects, such as furniture, pillows, bedding, paper, clothes, curtains etc. at a safe distance of at least 100 cm away from the panel heater.

  • Do not operate the appliance in areas of use or storage of combustible substances. Do not operate the appliance in areas of combustible media (for example in close proximity to inflammable gases or aerosols) – there is great risk of explosion and fire!

  • Do not insert and do not allow foreign objects to enter the ventilation openings (inlet and outlet) because this will cause electric shock, fire or will damage the appliance.

  • The appliance is not suitable for animal breeding. The panel heater is intended for domestic/indoor operation only.

  • When positioning the appliance, do not cover the safety grilles; do not hamper the incoming and outgoing air flow. All objects must be at a safe distance of at least 1 meter away from the appliance front and sides.

  • The most common reason for overheating is dust and fluff deposits in the appliance. Clean the ventilation openings on a regular basis with a vacuum cleaner, but before that it is very important to disconnect the heater from the mains.

  • Never touch the appliance with wet or moist hands – there is risk for your life!

  • The power socket should be accessible all the time in order to disconnect the power plug when needed as fast as possible! Never pull the power cord or the appliance itself in order to disconnect it from the mains.

  • PAY ATTENTION! Outgoing air gets heated during appliance operation (up to more than 100°С).

  • If you decide to stop using an appliance of this kind, it is recommended to make it unusable by cutting its power cord after you have disconnected it from the mains. It is advisable all possible risks related to the appliance to be secured, especially in relation to children that may play with out-of-use appliances.

  • Warning: Do not use this appliance with a programmer, counter or any other mechanism which could automatically turn on the heater – if the appliance is covered or positioned incorrectly there is a risk of fire.

  • Position the power cord in such a way that it does not obstruct the free movement of people and cannot be stepped on! Use only approved extension cords, which are suitable for this appliance, i.e. they have a compliance sign!

  • Never move the appliance by pulling its power cord; do not use the power cord for carrying other objects!

  • Do not bend the power cord and do not pull it against sharp edges; do not place the power cord on hot surfaces or open fire!

  • The scattered UVA light emitted by the device is harmless to the eyes. Looking directly at UVA light is not recommended.

PACKING
  • After unpacking the appliance, check if its contents are intact and if it has not been damaged during transportation! In case a damage or incomplete delivery is found, contact your authorized retailer!
  • Do not dispose of the original packing box! It could be used for storage and transportation purposes in order to avoid damages during transportation!
  • Disposal of packing material should be done in the appropriate way! Children must be prevented from playing with polyethylene bags!
INSTALLATION INSTRUCTIONS
  • This panel heater is designed to be used indoors, mounted on a wall.

  • Do not position the panel heater under a power socket or electricity connection box.

  • DO NOT install/operate the panel heater:

    • in places where a draught is present, which could influence the control settings;
    • right under a power socket;
    • in “Volume 1” for bathrooms;
    • in “Volume 2” if the control board can be reached by a person who is in a shower or in a bathtub;
  • for the wall-mounting of the panel heater, only the wall braces must be used which are delivered together with the appliance. When installing the panel heater, minimum safe distances must be observed
    INSTALLATION INSTRUCTIONS 01

  • First of all, remove the wall braces from the back of the appliance body. Unscrew the two screws which are positioned at the upper part of the two vertical bars of the wall braces. Then pull the upper part of the bar by pressing strongly the two upper parts which are inserted in the back of the body.
    INSTALLATION INSTRUCTIONS 02

  • Slide down the wall brace in order to detach it from the back of the body.

  • Attach firmly the wall brace onto a wall through the four screw holes.

  • Lift the panel heater up to almost vertical position and insert the two lower protruding parts of the braces into the two lower openings of the back cover of the panel heater. Then lift the panel heater and insert the two upper protruding parts of the wall braces into the two upper openings of the back cover of the heater. Finally, put the two screws back to their places and tighten them in order to install the panel heater firmly to the wall.

BATHROOM OPERATION
  • The panel heater must be installed in accordance with the normal trade practices and in compliance with the national legislation (EU electricity directives and regulations concerning special installations and places of operation including bathrooms, shower cabins HD60364-7-701(IEC 60364-7-701:2006)).
    BATHROOM OPERATION

  • In case this panel heater is to be used in a bathroom or other similar room, the following installation requirements must be observed: the panel heater is with IP24 protection (water drops protection). Hence it can be installed in “Volume 2” (see the diagram below) in order to avoid the risk of the control board (power switch and thermo regulator) being reached by a person who is in a shower or a bathtub. The minimum distance between the appliance and a water source should be not less than 1 meter and it is compulsory the appliance to be wall-mounted! If you do not feel sure about the installation of this panel heater in a bathroom, we recommend you to consult a professional electrician.

  • In wet premises the power source must be installed at a height of at least 25 cm above the floor (bathrooms and kitchens).

  • The installation must be equipped with a safety fuse, and the distance between the fuse contacts in disconnected condition should be at least 3 mm.

This is a product providing heating in winter depending on the consumers’ needs for comfortable room temperature. If operated and taken care of properly in accordance with these instructions, the appliance will provide you with many years of useful operation.

OPERATION INSTRUCTIONS
  • Hold for 1.5 sec ON/OFF button for OFF or ON the heater.
  • Step back – push the ON/OFF button until 1 seconds
  • Quick menu/Confirmation – push the Mode button until 1 seconds
  • Full menu – hold the Mode button over 3 seconds

OPERATION INSTRUCTIONS

Predefined Functions

Comfort Mode; Eco Mode; Sleep Mode

Comfort Mode – with On/Off option – allows the user to set a desired temperature when being at home. After once set it and the function is switched On, the appliance will keep the same room temperature each time of usage. This temperature to be set at 23°C by default.

Activation of “Comfort Mode”

  • Push the button “Mode” for 3 sec and select “Comfort mode” by pushing any of the buttons: UP and DOWN and confirm with “Mode” button. After that you should set the comfort temperature.
  • By pushing any of the buttons UP or DOWN set the desired temperature. Confirm with “Mode” button.
  • The “Comfort” mode is activated.

Deactivation of “Comfort Mode”

  • To deactivate the “Comfort” mode press “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press “Mode” button to choose different mode.

Visualization on Display in “Comfort” Mode Settings

  • Set Temperature
    The display shows “Comfort” in the top and the set temperature
    Visualization on Display in Comfort Mode Settings 01

Eco Mode – with On/Off option – allows the user to set a desired temperature when being out of home. After once set it and the function is switched On, the appliance will keep the same room temperature each time of usage. This temperature will be set at 18°C by default. User could also set the time when the appliance to switch to Comfort mode.

Activation of “Eco” Mode
Push the button “Mode” for 3 sec and select “Eco” mode by pushing any of the buttons: or and confirm with “Mode” button. After that you should set the temperature – by pushing any of the buttons UP or DOWN set the desired temperature. Confirm with “Mode” button.
If you want you can set the clock time:

  • Select by pushing any of the buttons: UP or DOWN reach actual hour time. Confirm with “Mode” button.
  • The minute icon is flashing and by pushing any of the buttons: UP or DOWN reach actual minute time. Confirm with “Mode” button (range 00.00-24.00).

When the set time has elapse, the appliance going to Comfort mode!

Deactivation of “Eco” Mode

  • You can exit “Eco” mode by pushing “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press “Mode” button to choose different mode.

Visualization on Display in “Eco” Mode Settings

  • Set temperature

The display shows “Eco” in the top and the set temperature

Visualization on Display in Eco Mode Settings

Sleep Mode with On/Off option – Two hours after activation, the convector decreases the set temperature with -3°C under the set temperature in Comfort mode. User could set the time range for operating in Sleep mode then the appliance switches to Comfort mode. By default: 6 hours.

Activation of “Sleep Mode”
Push the button “Mode” for 3 sec and select “Sleep mode” by pushing any of the buttons: UP or DOWN, and confirm with “Mode” button If you want you can set the clock time: select by pushing any of the buttons: UP or DOWN, reach actual hour time. Confirm with “Mode” button. The minute icon is flashing and by pushing any of the buttons: UP or DOWN, reach actual minute time. Confirm with “Mode” button (range 00.00-24.00). When the set time has elapse, the appliance going to Comfort mode!

Deactivation of “Sleep Mode”
User can exit “Sleep mode” by pushing “On/Off” button for 1.5 sec. Then the heater turns off. The display will continue showing the set temperature. Or press “Mode” button to choose different mode.

Visualization on Display in “Sleep” Mode Settings

  • Set temperature

The display shows “Sleep” in the top and the set temperature

Visualization on Display in Sleep Mode Settings

Basic Modes

“Heating” Mode

Start “Heating” mode
When the panel heater is switched-off its digital display shows symbol.

Heating Mode 01

By pushing the ON/OFF button for 1.5 sec the appliance goes into “Heating” mode. Then the display indicates mode. The set temperature is indicating in the right. If the room temperature is lower than the set one, the heater will switch automatically on, and a heating sign will appear on the display.
The display shows in the top and the set temperature

Heating Mode 02

Deactivation of “Heating” mode
User can exit “Heating” mode by pushing “On/Off” button for 1.5 sec. Then the heater turns off. The display will be showing OFF.

Temperature Adjustment
By pushing any of the buttons: UP or DOWN the user enters “Temperature adjustment” mode and the user can change the temperature settings in the desired direction. The new settings are saved and the heater goes automatically into “Heating” mode . If any of UP or DOWN buttons get pressed longer than 0.5 sec., the temperature settings will start automatically increase or decrease at a rate of 6 units per second. The range of available temperature settings is from 10 up to 30 degrees.

Delay Start Function
The delay start function allows the user to set the time at which the convector will switch on and start heating.

Push the “Mode” button for 3 sec and select “Delay Start” by pushing any of the buttons: or and confirm with “Mode” button, user can enter the time and temperature, when it will automatically go to “Heating” mode. Initially a setting of 12 hours is set by default and by pushing or buttons user can change the time settings in the desired direction. After the hour of “delay start” mode is chosen, press “Mode” button for confirmation. After that set the temperature at which the convector will start operating by pushing of any of buttons: UP or DOWN. Confirm with “Mode” button . If any of or buttons is held for more than 0.5 seconds, the time and temperature settings start automatically increase or decrease at a rate of 4 units per second. Confirm with “Mode” button or don’t press any button for 3 seconds.
If user enters time – 00, this mode will not be implemented. If the “Delay start” mode is already enabled and user selects the “Delay Start” mode again, it can be changed the remaining time in both possible directions. You can exit this mode by pushing the “On/Off” button. Then panel heater will go into “Heating” mode. The “Delay start” needs to be set from 0 to 96 hours.

Visualization on Display in “Delay Start” Settings
The display shows “Delay start” in the top and the set temperature

Visualization on Display in Delay Start Settings

Anti-frost Mode

If the room temperature falls below 5°C and the panel heater is off, the heater will turn on automatically in order to prevent freezing of the area. Indication – in left top corner – only when work the anti-frost mode
Factory settings of the function is ON (switched On).

Activation and Deactivation of Anti-frost Mode

  • If the customer wants to change it – push “Mode” button for 3 sec and select “Anti-frost” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button and user can push DOWN button to reach “OFF”. Confirm with “Mode” button.

To activate the function – push “Mode” button for 3 sec and select “Anti- frost” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button. It starts blinking and user has to push UP button to reach “ON”. Confirm with “Mode” button.

Visualization on Display in “Anti-frost” Settings

Visualization on Display in Anti Frost Settings

“Temperature Correction for the Sensor” Function
Due to the specifics of the temperature profile in some premises there may be difference from the temperature shown on the display and the actually measured temperature in the various locations of the heating appliance in the room.
See the temperature shown on the display of the appliance
Measure the temperature at a place where the temperature is “comfortable” enough for you (usually at a height of 60 cm from the floor, in sitting position). If you find a difference within a range of ±4°С, you can set the necessary correction in the convector’s menu (It is important to note that this function can be set only after the temperature has become the same all around the room, and depending on the room type, the minimum required time is 7 hours) by entering the temperature difference resulting between the value on the display and the actually measured temperature.
This function is used with the purpose of providing better temperature comfort and energy saving for the user of the electric convector in the room which it is in. A temperature difference greater than ±4 °C from the measured temperature in a specific location in the room indicates that the room where you use the convector in is not well insulated or the temperature is not the same all around the room.
Example: a convector in a room on a stone floor – the convector displays 18°С (the set temperature is 22°С), the actually measured temperature (feeling of reached comfort temperature) is 22°С at a height of 60 cm from the floor – > in this case the convector continues to overheat the room (this is a direct energy loss, but the convector cannot reach the set temperature because it measures the temperature at a low height close to the floor) and it will never switch off. In this case a temperature correction of +4°С needs to be applied to the sensor, thus the convector will display 22°С and it will start switching off, and eventually it will maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
If the customer wants to change it – by pushing “Mode” button for 3 sec and select “Temperature correction” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button – by pushing UP or DOWN button user can reach a temperature correction in the diapason from “-4°C” up to “+4°C”. Confirm with “Mode” button.
If user wants to see the already set correction, should press “Mode” button for 3 sec and select “Temperature correction” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button. User can change it by pushing button UP or DOWN to give a new value of correction in the diapason ±4°C. Confirm with “Mode” button.

If the factory reset function is used, the temperature correction has to be set again. The factory setting of its value is 0°C.

Visualization on Display in “Temperature Correction” Settings

Visualization on Display in Temperature Correction
Settings

Function Adaptive Start
Adaptive start is a function which predicts and initiates the optimal start of heating in order to reach the set-point temperature at the desired time; Test according to user instruction / documentation. The function is tested in a room with a continuous heat demand of 50 – 60% with reference to the wattage of the test device. The product is working at a comfort temperature 23°C ± 3°C setpoint until stable conditions. This temperature is the reference comfort temperature “Ct”. Activate a set-back period of 7h +2h/-0h per 24h with a set- back of 4°C ± 1°C . The comfort period being 17 -2h/+0h hours. With the adaptive control activated – let the heater thermostat working during 4 periods (4 x 24 hours) of comfort and low setback cycles. After the latest low setback period finishes the comfort temperature “Ct” should be reached within ± 30 minutes deviation to the time target – with a maximal difference of ± 1°C from the reference comfort temperature “Ct”.

  • Factory settings of the function is “ON”

Deactivation of Function Adaptive Start

  • If the customer wants to change it – by pushing the “Mode” button for 3 sec and select “Adaptive start” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button and user can push DOWN button to reach “OFF”. Confirm with “Mode” button. In this case, the function adaptive start is switched OFF.

Activation of Function Adaptive Start
To return again in condition “ON” – by pushing the “Mode” button for 3 sec and select “Adaptive start” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button and user can push UP button to reach “ON”. Confirm with “Mode” button. In this case the function Adaptive start is switched ON.

Visualization on Display in “Adaptive Start” Settings

Visualization on Display in Adaptive Start Settings

RESET to Default Settings
If the customer wants reset the convector to factory settings – by pushing the “Mode” button for 3 sec and select “RESET” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button.

Visualization on Display in “RESET” Settings

Visualization on Display in RESET Settings

After using the reset function, the following functions will be reset:

  • clock time
  • temperature correction value 0°C
  • function Anti-frost mode is activated
  • adaptive start is activated
  • weekly program – 24/7 is reset.

Open Window/Door Function
Room temperature control with open window detection – the product is equipped with an integrated electronic device that reduces the heat output when detects an open window or door. A sensor is used to detect eventual drop in the room temperature. If the temperature falls more than 5˚C, the convector will switch off by itself. Within 15 min the open window detection should turn the appliance off. When the room temperature rises by at least 0.5°C and the difference from the initial set point is below 5°C, the convector switches itself on with the settings already made. If the temperature does not rise for more than 60 minutes, the convector enters Standby mode. The function is allowed to be cancelled manually.
The function can be switched Off manually.

Deactivation of Open Window/Door Function:
If the customer wants to change it – by pushing the “Mode” button for 3 sec and select “Open window” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button. User has to push DOWN button to reach “OFF”. Confirm with “Mode” button. In this case function “Open window” is switched OFF.

Activation of Open Window/Door Function:
To return again in condition “ON” – by pushing the “Mode” button for 3 sec and select “Open window” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button. User has to push UP button to reach “ON”. Confirm with “Mode” button. In this case function “Open window” is switched ON.

Visualization on Display in “Open Window” Settings

Visualization on Display in Open Window Settings

Keyboard Lock (Protection from Children)
When user turns on this function, all keys of the control panel remain locked.
Hold buttons and “Mode” together for 3 seconds. The display should show a message when this mode is activated. When user wants to turn off this function has to hold the same button combination for 3 seconds.
Activation/deactivation: Holding DOWN and “Mode” buttons for 3 seconds the keyboard gets locked.
To unlock the control panel, hold DOWN and “Mode” buttons for 3 seconds.

Visualization on Main Display when activating and deactivating the function “Protection from children”:

Visualization on Main Display when activating and
deactivating

Day and Time – Settings
First step or use after factory reset function
Set the current time and day by pushing the “Mode” button for 3 sec and select “DAY TIME” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button.

Set a Schedule for the First Day of the Week
Select “DAY OF THE WEEK” mode by pushing any of the buttons: UP or DOWN. Confirm with “Mode” button.
Select by pushing any of the buttons: UP or DOWN reach current day of the week (Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday). Confirm with “Mode” button.

Set a schedule for the first day of the week

Errors mode:
If the display shows “t1” or “t2”, this means that the self-diagnostic system has found a problem with the temperature sensor. “t1” indicates a disconnected cable at the sensor, while “t2” indicates short circuit at the sensor. In this case the electric convector will be automatically switched off and it can be switched on again only after the problem has been fixed. The problem has to be handled by a qualified specialist.

DISCONNECTION FROM THE POWER SUPPLY:
If the electric convector is disconnected from the mains, this will not affect the set temperature and the mode of operation which has been active prior to its disconnection. If for example the convector has been in “Heating” mode, after it has been disconnected and reconnected to the mains, it will continue operating in the same mode with the same set temperature.
The principle of operation of the electric convector with energy-independent memory is to store the settings for 120 minutes guaranteed, and up to 180 minutes not guaranteed.
If the time is more than 120 min the appliance going to Stand by mode.

PROTECTION
  • The appliance is equipped with a safety thermo turn-off device, which automatically turns the heater off in cases of extreme temperature of the panel heater /i.e. overheating of the appliance/.
  • The safety thermo turn-off device will automatically restore the heater operation when the temperature of the appliance falls below the permissible ultimate values.
CLEANING
  • It is compulsory first to turn off the appliance through its power switch and to disconnect it from the power socket. Before starting the cleaning session you should wait until the panel heater cools down in a disconnected state.
  • The panel heater can be cleaned with little efforts at the appliance rear part – just press the “P”-shaped braces /figure 2/ at the back of the appliance so that you can dismantle it and consequently you can clean the rear part of the appliance.
  • Clean the heater body with damp cloth, vacuum cleaner or a brush.
  • Never immerse the appliance into water – there is danger for your life from electric shock!
  • Never use gasoline, thinner or hard abrasive products to clean the appliance, because they will damage the appliance coating.
STORAGE
  • Before putting the panel heater away let it cool down after you have disconnected it from the power socket
  • Use the appliance original packing to store it, if the panel heater will not be in use for a long period of time. By storing the product in its original packing you protect it from excessive dirt and dust accumulation.
  • Never put a hot panel heater in its packing!
  • It is necessary the product to be stored at a dry and dark place, protected from direct sun light.
  • It is explicitly forbidden to store the panel heater in damp and wet premises.
MAINTENANCE OPERATIONS OF THE APPLIANCE
  • In case of appliance malfunction, please contact the authorized service center closest to your location. /service centers are indicated in appliance warranty documents/.
  • Important: In case of a claim and/or violation of your consumer rights, please contact the supplier of this appliance at the indicated locations or via the Internet page of the company: www.tesy.com

DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM / APPLIANCE MODELS

DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM

Documents / Resources

| TESY CN 051 EI Electric Panel Heater [pdf] User Manual
500, 1000, 1500, 2000, 2500, 3000W, CN 051 EI Electric Panel Heater, Electric Panel Heater, Panel Heater
---|---